Rockford Systems Page 5 - C 4000 Safety Light Curtain

For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

Credit Card Images

C 4000 Safety Light Curtain Features and Benefits

The C 4000 safeguards personnel and machines in automated production areas and optimizes work processes. The C 4000 system is used vertically, horizontally or diagonally for safeguarding areas with potential hazards to personnel or equipment. With a flexible design to fit all applications, the C 4000 is simple to commission, maintain and very easy to use.
Efficient and Cost-effective Solutions

  • Flexibility. There is a C 4000 system for every application, from the simplest to the most advanced.
  • Simplified machine integration and lower wiring cost. There is no need for additional safety relay modules since controls are a part of the light curtain solution.
  • Advanced functions, self-diagnostics, E-stop, and reset controls all integrated into the light curtain.
  • Universal interface. Every C 4000 Safety Light Curtain works with all interface and control architectures: from relay and safe PLC control to safety field bus.
Light Curtain Introduction

The C 4000 Family at a Glance
The answer to your safety application: C 4000 Micro, Basic, Standard, Advanced and Entry/Exit solutions SICK's C 4000 Safety Light Curtain is the next generation of our FGS, the #1 selling light curtain worldwide.
C4000 Technology and System Advantages Standard/ Advanced

  • For all tasks up to Safety Category 4
  • Complete self-diagnostics
  • Integrated control capabilities
  • Programmable configurations via CDS software
  • Compatible with Intelliface™ family of interfaces

Advanced

  • Most advanced light curtain solution
  • Complete blanking and reduced resolution
  • Teach-in blanking capabilities

C 4000 Palletizer

  • Supplemental safeguard for automated manufacturing applications
  • Innovative pattern recognition technology eliminates need for muting
  • Self-learning or manual object size definition and tolerance
  • Detect five smaller or one large object
  • Can be positioned horizontally or at an angle

And now introducing the C 4000 ECO/Basic Plus

  • Simple point-of-operation safeguarding
  • Entry level light curtain solutions
  • Most economical solution for all tasks to
  • Safety Category 4
  • Low installation cost

Tell us about your application. We will recommend a C 4000 solution that is right for you.

Light Curtain Applications

Benefits of C 4000 System

  • Monitoring of receiver cable along entire length through the semi-conductor outputs of the safety light curtain
  • Direct connection of Emergency Stop and Reset control units to the C 4000
  • No need for separate Emergency Stop and light curtain safety relays
  • Uniform diagnosis and configuration
  • Less control cabinet space required
  • Lower wiring costs
  • Easier engineering, as fewer components are required
  • Reduced inventory costs, as fewer components are required

Customary savings per machine - minimum $200 Savings per 100 machines - minimum $20,000

Light Curtain Benefits

Safety and Availability

  • State-of-the-art technology. Type 4 third-party certification in accordance with ANSIjULjlECjEN 61496-1, -2. The C 4000 is the first safety light curtain that is also third-party certified to IEC 61508.
  • Maximum availability. Shorter downtime through local diagnostic indication (seven-segment display). Beam coding minimizes optical interference from machines in close proximity.
  • Seven-segment display: alphanumeric display panel can rotate 1800•
  • Fastest response time in the industry. Improved safety and productivity. Shorter safety dis­tances, less floor space.
  • Complete suite of advanced functions. Comprehensive and flexible blanking configurations, reduced resolution muting.
  • Flexibility. With resolutions of 14 to 40 mm, and protective heights from 150 to 1800 mm, the system can be applied to most safety applications.

Engineering and Maintenance

  • Rapid installation and commissioning. Software configurable with CDS software from SICK. Simplified alignment at short and medium ranges. Preconfigured versions available so that no software is required.
  • Easy integration, low wiring cost. Cascadable design, up to 3 linked protective fields are possible with one output signal. Installation of up to 3 m cables between sensor pairs.
  • Simplified machine integration. Small, compact design. No additional control unit required. Advanced functions, self-diagnostics, E-stop and reset controls are all integrated in the sensor.
  • Shorter refitting times. Selectable user-modes (with UE 402) reduce re-tooling times and shorten downtime during operating mode changes. "Real time" user-mode changes.
  • Teach-in blanking. Simple teach-in at the press of a button to shorten tool change times and greater availability.
  • Simple mounting and adjustment. Corner mirrors and protective screens reduce repair and maintenance cost.

Operational

  • Reduced inventory. All-inclusive solution, less parts to stock.
  • Universal interface. The same light curtain can be used with all interface and control architectures: from relay and safe PLC control to safety field bus.
  • Cost-effective integrated safety platform.
  • Common software platform with scanners, bus nodes, etc.

C 4000 Family Product Selection
  C4000 ECO C4000 Basic Plus C4000 Micro C4000 Standard C4000 Advanced C4000 Entry-Exit C4000 Palletizer Standard C4000 Palletizer Advanced

C 4000 Family
Product Selection

C4000 ECO

C4000
BASIC PLUS

C4000 MICRO

C4000
STANDARD

C4000
ADVANCED

C4000
ENTRY/EXIT

C4000
PALLETIZER
STANDARD

C4000
PALLETIZER
ADVANCED

Available Resolutions (mm)

14,30

14,20,30,40

14,20,30,40

14,20,30,40

14,20,30,40

14,20,30,40

14,20,30,40

20

Available Protective Heights (mm)

300 …1200

300 ... 1800

300 ... 1800

300 ... 1800

300 ... 1800

300 ... 1800

300 ... 1800

900 ... 1800

Maximum Distance Between Sender and Receiver Units (Range)

14 mm Resolution (m)

5m

6

6

6

6

6

6

NA

20 mm Resolution (m)

NA

19

19

19

19

19

19

19

30 mm Resolution (m)

6m

19

19

19

19

19

19

NA

40 mm Resolution (m)

NA

19

19

19

19

19

19

NA

Housing Cross-Sectional Dimensions (mm)

40x48

40x48

25.8 x 33.5 mm

40x48

40x48

40x48

40x48

40x48

Type Designation per 61496 (ANSl/UL/IEC)

Type 4

Type 4

Type 4

Type 4

Type 4

Type 4

Type 4

Type 4

Safety Integrity Level (SIL) per EN 61508

SIL 3

SIL 3

SIL 3

SIL 3

SIL 3

SIL 3

SIL 3

SIL 3

Approvals

CE UL (US & C)

CE UL (US & C)

CE UL (US & C)

CE UL (US & C)

CE UL (US & C)

CE UL (US & C)

CE UL (US & C)

CE UL (US & C)

SICK Configuration
and Diagnostic Software
(Provided at No Charge when Available)

NA

Yes, but may not be
required in Guard Only
applications

Yes, but may not be
required in Guard Only
applications

Yes, but may not be
required in Guard Only
applications

Yes, for advanced
functionality
programming

Yes, for advanced
functionality
programming

Yes, for advanced
functionality
programming

Yes, for advanced
functionality
programming

Seven-segment Diagnostic Display

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

External Device Monitoring

Yes**

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Restart Interlock

Automatic Restart

Yes**

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Manual Restart

Yes**

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Restart Required Output

Yes**

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Cascadability

Stand Alone

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Host-Guest Configurations

NA

Guest Only

Guest Only

Host or Guest

Guest Only

Guest Only

Host or Guest

NA

Host-Middle Guest-End
Guest Configurations

NA

End Guest Only

NA

Host or Middle
Guest

End Guest Only

NA

Host or Guest

NA

Direct Connection Emergency Stop/Interlock

NA

NA

Yes

Yes

NA

Yes

Yes

NA

Application Diagnostic Output (Only One)

Emergency Stop or Interlock Status

NA

NA

Yes

Yes

NA

Yes

Yes

Yes

Front Lens Contamination

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

OSSD* Status

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Beam Coding

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Blanking Functionality (Up to Four Areas)

Fixed Blanking

NA

NA

NA

NA

Yes

Yes

Yes

NA

Floating Blanking

NA

NA

NA

NA

Yes

Yes

Yes

NA

Reduced Resolution

NA

NA

NA

NA

Yes

Yes

Yes

NA

Teach-in Functionality

NA

NA

NA

NA

Yes

Yes

Yes

NA

Dynamic Floating Blanking

NA

NA

NA

NA

NA

NA

NA

Yes

Connectivity Options (Sold Separately)

UE 10 Series Safety Relay Modules

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

UE 48 Series Safety Module

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

UE 100 Series Intelligent Interfaces

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

UE 1000 Safety Bus Interfaces

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

* OSSD: Output Signal Switching Device
** With UE48

NOTE:
Not all features can be combined. Refer to Installation and Operation Instructions for additional detail.
When an Emergency Stop or Interlock is connected to any C 4000 version, External Muting of the C 4000 is NOT ALLOWED.