The C 4000 safeguards personnel and machines in automated production areas and optimizes work processes. The C 4000 system is used vertically, horizontally or diagonally for safeguarding areas with potential hazards to personnel or equipment. With a flexible design to fit all applications, the C 4000 is simple to commission, maintain and very easy to use.
|
![]() |
The C 4000 Family at a Glance
Advanced
C 4000 Palletizer
And now introducing the C 4000 ECO/Basic Plus
Tell us about your application. We will recommend a C 4000 solution that is right for you. |
![]() |
Benefits of C 4000 System
Customary savings per machine - minimum $200 Savings per 100 machines - minimum $20,000 |
![]() |
Safety and Availability
Engineering and Maintenance
Operational
|
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||
C 4000 Family |
C4000 ECO |
C4000 |
C4000 MICRO |
C4000 |
C4000 |
C4000 |
C4000 |
C4000 |
Available Resolutions (mm) |
14,30 |
14,20,30,40 |
14,20,30,40 |
14,20,30,40 |
14,20,30,40 |
14,20,30,40 |
14,20,30,40 |
20 |
Available Protective Heights (mm) |
300 …1200 |
300 ... 1800 |
300 ... 1800 |
300 ... 1800 |
300 ... 1800 |
300 ... 1800 |
300 ... 1800 |
900 ... 1800 |
Maximum Distance Between Sender and Receiver Units (Range) |
||||||||
14 mm Resolution (m) |
5m |
6 |
6 |
6 |
6 |
6 |
6 |
NA |
20 mm Resolution (m) |
NA |
19 |
19 |
19 |
19 |
19 |
19 |
19 |
30 mm Resolution (m) |
6m |
19 |
19 |
19 |
19 |
19 |
19 |
NA |
40 mm Resolution (m) |
NA |
19 |
19 |
19 |
19 |
19 |
19 |
NA |
Housing Cross-Sectional Dimensions (mm) |
40x48 |
40x48 |
25.8 x 33.5 mm |
40x48 |
40x48 |
40x48 |
40x48 |
40x48 |
Type Designation per 61496 (ANSl/UL/IEC) |
Type 4 |
Type 4 |
Type 4 |
Type 4 |
Type 4 |
Type 4 |
Type 4 |
Type 4 |
Safety Integrity Level (SIL) per EN 61508 |
SIL 3 |
SIL 3 |
SIL 3 |
SIL 3 |
SIL 3 |
SIL 3 |
SIL 3 |
SIL 3 |
Approvals |
CE UL (US & C) |
CE UL (US & C) |
CE UL (US & C) |
CE UL (US & C) |
CE UL (US & C) |
CE UL (US & C) |
CE UL (US & C) |
CE UL (US & C) |
SICK Configuration |
NA |
Yes, but may not be |
Yes, but may not be |
Yes, but may not be |
Yes, for advanced |
Yes, for advanced |
Yes, for advanced |
Yes, for advanced |
Seven-segment Diagnostic Display |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
External Device Monitoring |
Yes** |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Restart Interlock |
||||||||
Automatic Restart |
Yes** |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Manual Restart |
Yes** |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Restart Required Output |
Yes** |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Cascadability |
||||||||
Stand Alone |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Host-Guest Configurations |
NA |
Guest Only |
Guest Only |
Host or Guest |
Guest Only |
Guest Only |
Host or Guest |
NA |
Host-Middle Guest-End |
NA |
End Guest Only |
NA |
Host or Middle |
End Guest Only |
NA |
Host or Guest |
NA |
Direct Connection Emergency Stop/Interlock |
NA |
NA |
Yes |
Yes |
NA |
Yes |
Yes |
NA |
Application Diagnostic Output (Only One) |
||||||||
Emergency Stop or Interlock Status |
NA |
NA |
Yes |
Yes |
NA |
Yes |
Yes |
Yes |
Front Lens Contamination |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
OSSD* Status |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Beam Coding |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Blanking Functionality (Up to Four Areas) |
||||||||
Fixed Blanking |
NA |
NA |
NA |
NA |
Yes |
Yes |
Yes |
NA |
Floating Blanking |
NA |
NA |
NA |
NA |
Yes |
Yes |
Yes |
NA |
Reduced Resolution |
NA |
NA |
NA |
NA |
Yes |
Yes |
Yes |
NA |
Teach-in Functionality |
NA |
NA |
NA |
NA |
Yes |
Yes |
Yes |
NA |
Dynamic Floating Blanking |
NA |
NA |
NA |
NA |
NA |
NA |
NA |
Yes |
Connectivity Options (Sold Separately) |
||||||||
UE 10 Series Safety Relay Modules |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
UE 48 Series Safety Module |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
UE 100 Series Intelligent Interfaces |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
UE 1000 Safety Bus Interfaces |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
* OSSD: Output Signal Switching Device |
||||||||