For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
|
NORTH FRONTIER SELF-CONTAINED BREATHING APPARATUS |
|
![]() |
|
FEATURES |
BENEFITS |
Facepiece Options |
|
Choice of Silicone or Elastomeric |
|
Silicone seal with dual flange |
• Soft and comfortable for extended wear |
Elastomeric seal |
• Economical; secure fit in extreme heat |
Hard coated polycarbonate lens |
• High impact eye protection, scratch resistant |
200 degree wide field of vision |
• Safer use; anti-claustrophobic |
Lightweight |
• Comfortable, reduces fatigue |
2 overlapping sizes |
• Reduces inventory |
Oral/nasal cup standard |
• Limits re-breathing to reduce user fatigue |
Four point headstrap |
• Keeps facepiece secure without interfering with other safety helmets |
Hood Options |
|
Choice of PVC or Polyurethane |
|
Clear PVC hood with high chemical resistance |
• Anti-claustrophobic; emergency personnel can quickly identify wearers |
Blue polyurethane hood is cold-resistant |
• Use in cold environments or where refrigeration or coolants may be present |
Quick and easy to put on |
• Fast donning during emergencies when speed counts; reduces training requirements |
Use with prescription eyewear |
• No special optical inserts needed |
2 overlapping sizes |
• Comfortably fits most adults; reduces inventory |
Compact Demand Valve |
|
Smallest demand valve on the market |
• Fitting into tight spots is no problem |
Lightweight |
• Will not pull down on facepiece |
Side-mounted |
• Will not interfere with line of vision |
Bypass valve with adjustable flow |
• Provides as much, or as little extra air as needed in emergency |
Pressure Gauge & Alarm |
|
Chest-mounted Pressure Gauge |
• Easy access for quick and easy check |
Waterproof with luminous dial |
• Works in all environments, including Decon; Easy to read in low light |
Simple, chest-mounted whistle air alarm |
• Easy to hear in noisy environments (min 90 dB) |
Lightweight Harness Assembly |
|
Composite backplate, rugged, lightweight, ergonomic design |
• Holds up to harsh environments; comfortable during extended use |
Nylon harness |
• High chemical resistance; economical |
Kevlar harness optional |
• Superior abrasion and cut resistance |
Shoulder pads with velcro attachment |
• Comfortable, even weight distribution; removes for cleaning |
First Stage Reducer |
|
Simple piston design |
• Less complicated, less moving parts |
No adjustments required |
• No guessing or worry about getting the right setting |
Automatic, self-seating pressure relief valve |
• Protects downstream low pressure components |
![]() |
||
STANDARD FRONTIER' SELF-CONTAINED BREATHING APPARATUS |
||
Frontier standard models: includes facepiece or hood, cylinder and nylon harness assembly, shoulder pads, airline adapter, Compact Demand Valve with First Breath, adjustable flow by-pass and quick connect, and molded carrying case. |
||
PART NO. |
DESCRIPTION |
PACKAGING |
30 minute hoop wrapped cylinder, low pressure (2216 psi) |
||
912332FB |
92000 Series silicone facepiece, small or medium/large. Add S for small |
Each |
913332FB |
93000 Series elastomeric facepiece, small or medium/large. Add S for small |
Each |
914332FB |
94000 Series polyurethane hood. Small/medium or large/xl. Add S for S/M hood |
Each |
915332FB |
95000 Series PVC hood. Small/medium or large/xl. Add S for S/M hood |
Each |
30 minute carbon cylinder, high pressure (4500 psi) |
||
912632FB |
92000 Series silicone facepiece, small or medium/large. Add S for small |
Each |
913632FB |
93000 Series elastomeric facepiece, small or medium/large. Add S for small |
Each |
914632FB |
94000 Series polyurethane hood. Small/medium or large/xl. Add S for S/M hood |
Each |
915632FB |
95000 Series PVC hood. Small/medium or large/xl. Add S for S/M hood |
Each |
60 minute carbon cylinder, high pressure (4500 psi) |
||
912132FB |
92000 Series silicone facepiece, small or medium/large. Add S for small |
Each |
913132FB |
93000 Series elastomeric facepiece, small or medium/large. Add S for small |
Each |
914132FB |
94000 Series polyurethane hood. Small/medium or large/xl. Add S for S/M hood |
Each |
915132FB |
95000 Series PVC hood. Small/medium or large/xl. Add S for S/M hood |
Each |
ECONOMY FRONTIER' SELF-CONTAINED BREATHING APPARATUS |
||
Frontier economy models: includes facepiece or hood, cylinder and nylon harness assembly and Compact Demand Valve with adjustable flow by-pass 30 minute aluminum cylinder, low pressure (2216) |
||
913200 |
93000 Series elastomeric facepiece, small or medium/large. Add S for small |
Each |
915200 |
95000 Series PVC hood. Small/medium or large/xl. Add S for S/M hood |
Each |
![]() |
||
Turn your SeBA into a Pressure Demand Airline with Escape |
||
PART NO. |
DESCRIPTION |
PACKAGING |
Replacement Cylinders |
||
91 0301 LP |
30 minute aluminum, low pressure (2216 psi) |
Each |
910302LP |
30 minute hoop wrapped, low pressure (2216 psi) |
Each |
910303HP |
30 minute carbon, high pressure (4500 psi) |
Each |
910603HP |
60 minute carbon, high pressure (4500 psi) |
Each |
All SCBA and cylinders requested to ship overnight from North must be shipped without air. |
||
Air Supply Hoses |
||
900006FB |
6 foot air hose, 1/4" I.D., with Foster brass male and female coupler |
Each |
900025FB |
25 foot air hose, 1/4" I.D., with Foster brass male and female coupler |
Each |
900050FB |
50 foot air hose, 1/4" I.D., with Foster brass male and female coupler |
Each |
900100FB |
100 foot air hose, 1/4" I.D., with Foster brass male and female coupler |
Each |
![]() |
||
During an emergency you need an escape respirator that is quick and easy to put on, simple to use, and reliable. The answer is the North 845 and 850 EEBA. These self contained units supply a continuous flow of 5 or 10 minutes of air, allowing workers to safety exit from a contaminated area. |
||
FEATURE |
FUNCTION |
BENEFIT |
Transparent Polyurethane Hood |
• Anti-claustrophobic |
• Workers not use to respirators feel more comfortable |
Full flow of air at a quarter turn |
• Workers receive air flow as quickly as possible |
• Minimizes exposure to contaminants |
Air deflector |
• Directs air to front of hood, away from worker's eyes |
• More comfortable, eyes will not dry out |
Gauge not hidden inside bag |
• Always visible for inspection |
• Easy access to assure the EEBA is always filled and ready for use |
Pictogram Instructions on Carrying Bag |
• Understood in any language |
• No need to translate or provide special training |
High visibility Carrying Bag |
• Easy to see, even if area is obscured by fumes |
• Crew members can locate their EEBAs quickly, even during the confusion immediately after an incident |
Adjustable straps on Carrying Bag |
• Can be worn around waist or slung over |
• Crew members can strap their EEBA on to keep at the ready, or grab and go at the last minute |
Nylon Carrying bag with Velcro cover for hood |
• Easy to clean and maintain |
• Protection for EEBA when not in use |
42 Ipm of breathing air |
• Higher flow rate than many units so worker is less likely to over breathe |
• Safer and more comfortable |
Aluminum Cylinder |
• 5 year hydrostatic test versus 3 years for composite cylinders |
• Saves time, money and hassle of removing cylinders from service every 3 years |
845 can be used to -25°F (-30°C) |
• Ideal for colder environments and for exposure to chemicals that can cause freezing (e.g. ammonia) |
• Safe to use no matter the time of year or potential hazardous material |
PART NO. |
DESCRIPTION |
PACKAGING |
845 |
5 minute EEBA |
Each |
850 |
10 minute EEBA |
Each |
| WSP home page | Products page | Suppliers page | |
| Respiratory Protection | North Respirator Index | Previous North Respirator Page | Next North Respirator Page |