North Respirators Page 3 - Supplied Air Respirators

For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

Credit Card Images

CF2007 For Half Mask and Full Facepieces
CF2007 Continuous Flow Supplied Air for Facepieces

Convert your North half mask or full facepiece to continuous flow with the CF2007. This breathing tube attaches to North facepiece cartridge connectors, eliminating the need for special adapters or tools. NIOSH approved for use with North 5500, 7700, 5400 and 7600 Series including full face pieces with welding front.

FEATURES

FUNCTION

BENEFIT

Threads onto North cartridge connectors

• Adapts to North 5500 & 7700 half masks and 5400 & 7600 full facepieces

• Choose the right facepiece for your work
environment and budget
• Provides flexibility for different worksite protection levels
• No additional fit testing

Breathing tube hoses are located on worker's back

• Hoses are out of the way of the work zone
• Even weight distribution
• Hose will not pull down on facepiece

• Will not interfere with tasks at hand
• Less worker fatigue
• More secure fit

Low profile connections

• When used with half maSk, fits under welding helmets and faceshields

• Add additional eye and face protection for welding, grinding and other applications

NIOSH approved for use with 5400 and 7600 with welding adapter

• May be used for welding applications

• Provide welders with the increased respiratory
protection of a full facepiece

360 degree swivel on face piece connection

• Allows full movement of breathing tube without loosening the connection

• Extra secure and safe - will not come off even during the most strenuous movements

Soft flexible hoses at top, next to worker's
face and neck

• More comfortable
• Moves with worker

• Increased worker acceptance
• Improved productivity, workers are not restricted

Choice of two hose I.D. and three brands of couplers

• Assures breathing air couplers are incompatible with other gases
• 1/2" or 3/8" I.D. hoses

• Safer. You stay in compliance with OSHA
• Select the right hose I.D. for your worksite

PART NO.

DESCRIPTION

PACKAGING

CF2007

Breathing tube with threaded connections to convert North facepieces to supplied air. Includes breathing tube and waist belt

Each

CF2401,S

CF2007 breathing tube with 7600 full facepiece. Sizes medium/large and small

Each

7800 Series Full Facepiece with Cartridge Connectors
7800 Facepiece for Continuous Flow

Add the backup and piece of mind of air-purifying cartridges to your supplied air respirator. Use the air-purifying mode for entry, exit and emergency escape from the work environment without exposing workers to harmful contaminants. Ideal when workers must walk out to the air source connection, or would need to disconnect from hoses for a fast and safe escape in an emergency. NIOSH approved for use with 7580P100 filters and 7581P100 organic vapor, P100 filter cartridges.

FEATURES

FUNCTION

BENEFIT

7600 style silicone full facepiece

• All the great features of the 7600

• Increased worker comfort and acceptance

Available with adjustable flow control valve

• Allows each worker to increase or decrease air flow

• Increase flow during stretches of strenuous work
• Decrease flow when extra air is not needed

NIOSH approved with 8404 Welding Conversion Kit

• Facepiece can be converted for welding applications

• Welders get the increased respiratory protection of a full facepiece. Use combination cartridges when organic vapors may be present

Choice of two hose 1.0. and three brands of couplers

• Assures breathing air couplers are incompatible with other gases
• 1/2" or 3/8" I.D. hoses

• Safer. You stay in compliance with OSHA
• Select the right hose I.D. for your worksite

PART NO.

DESCRIPTION

PACKAGING

78005,S

Full Facepiece with breathing tube and cartridge connectors, fixed flow. Sizes medium/large and small

Each

78006,S

Full Facepiece with breathing tube and cartridge connectors, adjustable flow. Sizes medium/large and small

Each

WHICH I.D. HOSE IS RIGHT FOR YOUR WORKSITE?
North offers hoses in two inside diameters (I.D.), 1/2" and 3/8". 1/2" hoses allow more air to pass through, allowing the use of a lower PSI at the air source. This is best for portable ambient air pumps that will not support higher PSI requirements. 3/8" 1.0. hoses are smaller and lighter. This is especially important if you need 100' or more of hose and want to minimize how much weight workers must carry around at the worksite.
1/2" = more air flow
3/8" = less weight

85300 Series Hoods
85300 Series Hoods
85300 Series Hood Assemblies
Many workers appreciate the freedom hoods provide, employers appreciate not needing to fit test. Because hoods do not have a facepiece to face seal, you can accommodate workers with facial hair and prescription glasses - plus fit testing is not required. Because hoods are disposable, your clean up is also easier. Ideal for use in extremely dusty environments, for paint spray operations or other applications where respirators get dirty quickly. NIOSH approved with an APF of 1000.

FEATURES

FUNCTION

BENEFIT

GENERAL

Headgear with rachet adjustment

• Hood moves with worker
• Ratchet adjustment ensures headgear stays secure without being too tight

• View is never obstructed, even when turning head left or right
• More comfortable even after wearing for many hours

Assigned Protection Factor of 1000

• Highest APF available for non-IDLH environments

• Workers are protected, even in higher concentrations

Air deflector directs flow over inside of lens

• Air is delivered to the front where workers need it most
• Air does not blow directly into worker's eyes
• Reduces any chance of fogging

• Cooler and more comfortable
• Eyes will not dry out
• Optimum visibility

Optional Vortex Tube

• Temperature can be adjusted to warm or cool plus or minus 30° F (17° C)

• Increased comfort and worker productivity

Choice of two hose I.D. and three brands of couplers

• Assures breathing air couplers are incompatible with other gases
• 1/2" or 3/8" 1.0. hoses

• Safer. You stay in compliance with OSHA
• Select the right hose I.D. for your worksite

DISPOSABLE HOOD. WITHOUT BIB

Elastic at neck covered in cotton

• Soft and comfortable for extended wear

• Greater worker acceptance
• Increased productivity

Available coated for intermittent splash

• Added protection, ideal when full chemical suit is not required

• Increased safety
• Lighter and more comfortable than chemical suit

DISPOSABLE HOOD. WITH BIB

Inner and outer bib design

• Inner bib tucks into clothing

• Directs air flow inside to keep workers cooler
• Workers stay cleaner, free of particulates

Outer bib is 12-1/2" (32 cm) long

• Protects the neck and shoulders

• Long enough to provide the added protection, not too long to interfere

PART NO.

DESCRIPTION

PACKAGING

HOOD ASSEMBLY INCLUDES HOOD, HEADGEAR WITH RATCHET ADJUSTMENT, BREATHING TUBE AND WAIST BELT.

8530n

Hood Assembly with cotton neck

Each

8530nB

Hood Assembly with bib

Each

85301S

Coated Hood Assembly with cotton neck

Each

85301SB

Coated Hood Assembly with bib

Each

REPLACEMENT HOODS

85302TA

Hood with cotton neck seal

10 per package

85302TBA

Hood with bib

10 per package

85302SA

Coated Hood with cotton neck seal

10 per package

85302SBA

Coated Hood with bib

10 per package

Vortex Tube

The vortex tube provides greater comfort to the worker by cooling or warming the breathing air. It is color coded and simple to use. Air temperature can be adjusted to warm or cool the air by plus or minus 30°F. The vortex tube comes pre-assembled with Hansen (HV), Schrader (SV) or Snap-Tite (STV) couplers. For use with 85300 Hoods for either heating or cooling.

PART NO.

DESCRIPTION

PACKAGING

88600

Vortex Tube for 3/8" 1.0. hose - Add suffix to specify Hansen (HV), Schrader (SV), or Snap-Tite (STV) Couplers

Each

88800

Vortex Tube for 1/2" 1.0. hose - Add suffix to specify Hansen (HV), Schrader (SV), or Snap-Tite (STV) Couplers

Each

North Ambient Air Pumps
Ambient Air Pumps

North ambient air pumps meet continuous flow applications for up to three workers. Pumps are available individually or as part of a complete package.
Pumps and pump kits are not available in United States or Mexico.

FEATURES

FUNCTION

BENEFIT

     

Lightweight

• Portable

• Flexibility to be used at multiple sites, or stored when not in use

Uses standard electrical outlet

• No special wiring required

• Ready to plug in and use immediately
• Can be used at multiple worksites without concern about compatibility

Available as a complete supplied air system

• Includes pump, facepiece or hood, breathing tube, hoses and couplers
• Correct size pump for the respirator configuration

• Assurance you have everything needed for an airline systems
• Know that workers are properly protected with the right air flow

PART NO.

DESCRIPTION

PACKAGING

AMBIENT AIR PUMP

86600

1/4 H.P. Ambient Air Pump

Each

86610

3/4 H.P. Ambient Air Pump

Each

86630

1 1/2 H.P. Ambient Air Pump

Each

Complete Pump Kit. Contains (1) pump, (1) facepiece or hood, (1) breathing tube, (1) 50' hose and (1) set Hansen couplers for connection from breathing tube to hose

APPA

One person Pump Kit, 3/4 H.P. pump, 54001 Full Facepiece and CF2007 breathing tube.
Facepiece size medium/large

Each

APPB

One person Pump Kit, 3/4 H.P. pump, 85301T Hood, no bib

Each

APPC

One person Pump Kit, 3/4 H.P. pump, 7700 Half Mask and CF2007 breathing tube. Half Mask size medium

Each

APPD

One person Pump Kit, 1/4 H.P. pump, 54001 Full Facepiece and CF2007 breathing tube.
Facepiece size medium/large

Each

APPE

One person Pump Kit, 1/4 H.P. pump, 7700 Half Mask and CF2007 breathing tube. Half Mask size medium
CF2007 breathing tube. Half Mask size medium

Each

PART NO.

HORSE POWER

WEIGHT

MAX
CFM

# OF PEOPLE

RECOMMEND HOSES WITH HANSEN COUPLERS

86600

1/4 H.P.

33 lbs (15 kg)

5

1

25' 1/2" I.D., 888025H
50' 1/2" I.D., 888050H

86610

3/4 H.P.

55 lbs (25 kg)

10

2

25' 1/2" I.D., 888025H
50' 1/2" I.D., 888050H
100’ 1/2" I.D., 888100H

86630

1-1/2 H.P.

110 lbs (50 kg)

20

3

25' 1/2" I.D., 888025H
50' 1/2" I.D., 888050H
100' 1/2" I.D., 888100H

Assigned Protection Factor for Hoods

The Occupational Safety and Health Administration (OSHA) published new Assigned Protection Factors (APF) for all respirators in September, 2006. The new APF Table assigns two possible protection factors for supplied air and powered air-purifying hoods. All hoods now have an APF of 25 unless conditions outlined in footnote 4 from OSHA's Assigned Protection Factor Table are met.

FOOTNOTE FROM OSHA TABLE ON ASSIGNED PROTECTION FACTORS
The employer must have evidence provided by the respirator manufacturer that testing of these respirators demonstrates peliormance at a level of protection of 1,000 or greater to receive an APF of 1,000. This level of peliormance can best be demonstrated by peliorming a WPF* or SWPF study or equivalent testing. Absent such testing, all other PAPRs and SARs with helmets/hoods are to be treated as loose-fitting facepiece respirators, and receive an APF of 25.
WPF: Workplace Protection Factor
SWPF- Simulated Workplace Protection Factor

RESULTS
A minimum fit factor of 10,000 is required for the higher APF of 1,000 Primair Plus, All 10 subjects achieved fit factors in excess of 50,000
85300 Series, non-bib All 10 subjects achieved fit factors in excess of 70,000
85300 Series, with bib Lawrence Livermore Lab tests achieved fit factors averaging above 50,000
CONCLUSION
North by Honeywell has demonstrated that the North 85300 Series supplied air hoods, both with and without bib, and the Primair Plus PAPR hood have achieved the protection factors required for an OSHA APF of 1,000.

SERIES

PART NO.

DESCRIPTION

SWPF RESULTS

TESTED BY NORTH

Primair Plus Series
For Compact Air PAPR

PA111

Hood Assembly with Bib

>1,000

PA112

Replacement Hood with Bib

PA121

Coated Hood Assembly with Bib

PA122

Replacement Coated Hood with Bib

Primair FM 200 Series
For Compact Air PAPR

PA201 E01

Hood Assembly with E2 Hard Hat

>1,000

PA201 P01

Hood Assembly with P2N Hard Hat

PA231E01

Hood Assembly with Carbtex, E2 Hard Hat

PA231P01

Hood Assembly with Carbtex, P2N hard Hat

PA202

Replacement Hoods to Primair FM 200 Series

Primair FM 300 Series
For Compact Air PAPR

PA301

Hood Assembly

>1,000

PA331

Hood Assembly with Carbtex

PA302

Replacement Hoods for Primair FM 300 Series

85300 Series

8530n

Hood Assembly with Cotton Neck

>1,000

85302TA

Replacement Hood with Cotton Neck

85301S

Coated Hood Assembly with Cotton Neck

85302SA

Replacement Coated Hood with Cotton Neck

TESTED BY LIVERMORE LABS DURING ORIGINAL RESEARCH PROJECT

85300 Series

8530nB

Hood Assembly with Bib

>1,000

85302TBA

Replacement Hood with Bib

85301SB

Coated Hood Assembly with Bib

85302SBA

Replacement Coated Hood with Bib

85400 & 85500 Series Pressure Demand Airline Respirators (PDAR)
85400 & 85500 Series PDAR

The North 85400 and 85500 Series PDAR respirators feature North's popular silicone full facepiece with dual flange sealing area and superior optics. Models with escape cylinders feature slim 5 minute bottles. Use only one for 5 minutes of escape, or two bottles for a total of ten minutes of escape. Both series are NIOSH approved, and the 85500 may also be used in IDLH environments.

FEATURES

FUNCTION

BENEFIT

Available without escape, with 5 minute
or 10 minute escape

• Select the right PDAR for your work environment

• 85400 without escape to meet your budget
• 85500 with escape when protection in IDLH environments is required

85500 can accommodate one or two 5 minute cylinders

• Can be converted to 5 or 10 minute units

• Versatility. Use 5 minutes when weight is the critical
factor, 10 minutes when you need the extra escape
time

"Leap Frog" capability

• Allows user to connect to second air source before disconnecting to first source

• No interruption in air supply
• Allows workers to move more then the 300' max. allowed by OSHA

Ambidextrous

• Cylinders can be worn on left or right side

• Cylinders do not interfere with left handed workers

Escape cylinders can be taken off the belt, without interruption of air supply to facepiece

• Allows cylinders to be carried or dropped between the legs for a low profile

• Workers can safely enter or escape from a confined space or other constricted entrance without loss of air

PART NO.

DESCRIPTION

PACKAGING

85401,S

PDAR without escape cylinders, no escape cylinder option. Sizes medium/large and small

Each

85501,S

PDAR without escape cylinders, with option to add escape cylinders. Sizes medium/large and small

Each

85505,S

PDAR with one 5 minute escape bottle. Sizes medium/large and small

Each

85510,S

PDAR with two 5 minute escape bottles for total 10 minute escape. Sizes medium/large and small

Each

85525

5 minute escape bottle for 85501, 85505 and 85510

Each

85700 Series Combination PDAR and Air Purifying
85700 Series Combination PDAR and Air Purifying

The 85785 PDAR incorporates cartridge connectors for P100 filters so it can be used for entry, exit and escape from non-IDlH environments. This respirator is ideal where there are high particulates and workers need to travel to access the supplied air source. NIOSH approved for use with 7580P00 filters.

FEATURES

FUNCTION

BENEFIT

Silicone facepiece

• All the features of the popular 7600 series full facepiece

• Increased worker comfort and acceptance

Cartridge Connectors

• Use 7580P100 for entry, exit and emergency escape

• Allows PDAR to be used when workers need to walk distance to air supply

PART NO.

DESCRIPTION

PACKAGING

85785,S

PDAR with cartridge connectors. Sizes medium/large and small

Each

Compressor for Continuous Flow and Pressure Demand Airlines
Compressor

North offers this compact compressor for use in confined space or in other IDlH environments. This portable compressor will connect two workers using pressure demand respirators equipped with 5 or 10 minutes emergency egress. Warning alarm of 84db at 100 feet alerts workers of low pressure or power failure. The compressor will supply up to 100 psi.
Not available in United States and Mexico

FEATURES

FUNCTION

BENEFIT

Compact

• Can be transported

• Can be used at remote locations

Compressed air system

• Supplies up to 100 psi

• Use with PDAR
• Use with continuous flow configurations that can not be supported by smaller ambient air pumps

Warning alarm

• Sounds at 84 dB from 100 feet away

• Alerts workers of low pressure or a power failure

PART NO.

DESCRIPTION

PACKAGING

86620

Compressor

Each

Airline Hoses & Quick Connect Couplers
Couplers

North hoses are available for both 3/8" I.D. and 1/2" I.D. in 12-1/2', 25', 50', and 100' lengths. North offers Hansen, Schrader and Snap- Tite Quick Connect Couplers for connecting the hose to the facepiece or breathing hood, and the air source.
Warning: If more than one hose is required, join the hoses together. Do not use couplers between hose lengths. Only one 12-1/2 ft. or 25 ft. length of hose should be used in combination with any hose length to a maximum of 300 ft. OSHA requires that couplers not be interchangeable with any couplers used for non-breathing air or gas systems.

PART NO.

DESCRIPTION

AIR SUPPLY HOSES

886012

12-1/2 ft. Air Hose, 3/8" I.D.

886025

25 ft. Air Hose, 3/8" I.D.

886050

50 ft. Air Hose, 3/8" I.D.

886100

100 ft. Air Hose, 3/8" I.D.

888012

12-1/2 ft. Air Hose, 1/2" I.D.

888025

25 ft. Air Hose, 1/2" I.D.

888050

50 ft. Air Hose, 1/2" I.D.

888100

100 ft. Air Hose, 1/2" I.D

Description Hansen Part No. Snap-Tite Part No. Schrader Part No.

QUICK CONNECT COUPLERS FOR CONNECTING AIR SUPPLY HOSE TO HOOD OR FACEPIECE

Male plug with bushing for 3/8" NPT thread

880161H

880161ST

880161S

Female coupler for 3/8" I.D. Hose

880040H

880040ST

880040S

Female coupler for 1/2" I.D. Hose

880060H

880060ST

880060S

Coupler assembly for 3/8" I.D. Hose

88600H

88600ST

88600S

Coupler assembly for 1/2" I.D. Hose

88800H

88800ST

88800S

QUICK CONNECT COUPLERS FOR CONNECTING AIR SUPPLY HOSE TO AIR SOURCE

Male plug, for connecting to 3/8" I.D. Hose

880141H

880141ST

880141S

Male plug with bushing, for connecting to 1/2" I.D. Hose

880161H

880161ST

880161S

To attach coupler to air source Female coupler for air source with 1/4" NPT male thread

880040H

880040ST

880040S

Female coupler for air source with 1/4" NPT female thread

880041H

880041ST

880041S

Female coupler for air source with 3/8" NPT male thread

880060H

880060ST

880060S

Female coupler for air source with 3/8" NPT female thread

880061H

880061ST

880061S

HOSE ASSEMBLIES TO COMBINE 3/8" 1.0. HOSE WITH COUPLER ASSEMBLY FOR CONNECTING THE AIR SUPPLY HOSE TO HOOD OR FACEPIECE

12 1/2 ft. Air Hose, 3/8" I.D.

886012H

886012ST

886012S

25 ft. Air Hose, 3/8" I.D.

886025H

886012ST

886012S

50 ft. Air Hose, 3/8" I.D.

886050H

886050ST

886050S

100 ft. Air Hose, 3/8" I.D.

886100H

886100ST

886100S

Pressure Schedules

Make sure that the air supply hose is connected to a source of air meeting the most recent requirements for Grade D gaseous air as described in the ANSI/eGA 7.1 Commodity Specification for Air and containing not less than 19.5% oxygen by volume at sea level.

CONTINUOUS FLOW AIRLINE PRESSURE REQUIREMENTS

CFlOOO SERIES AIRLINE RESPIRATOR

HOSE LENGTH (feet)

AIR PRESSURE RANGE (psig)*

HOSE LENGTH (feet)

AIR PRESSURE RANGE (psig)*

For 886000 Series (3/8" I.D.) air hose and quick-connect coupler assemblies.

For 888000 Series (1/2" I.D.) air hose and quick-connect coupler assemblies.

12-1/2 - 25

7 -19

12-1/2 - 25

7 -19

50 - 75

9 -23

50 - 75

8- 21

100 -150

12-28

100 -150

9-22

175 - 300

17 -35

175 - 300

10- 25

85300 SERIES - CONTINUOUS FLOW AIRLINE HOOD RESPIRATOR

HOSE LENGTH (feet)

AIR PRESSURE RANGE (psig)*

HOSE LENGTH (feet)

AIR PRESSURE RANGE (psig)*

For 886000 Series (3/8" I.D.) air hose and quick-connect coupler assemblies

For 888000 Series (1/2" I.D.) air hose and quick-connect coupler assemblies.

12-1/2 - 25

9- 20

12-1/2 - 75

9-16

50 - 75

13 - 26

100-175

12 - 25

100 -125

16 - 35

200 - 225

14- 30

150 -175

20-41

250 - 300

16 - 33

200 - 225

23-47

 

 

250 - 300

26-53

 

 

8Sl00 SERIES - CONTINUOUS FLOW AIRLINE HOOD RESPIRATOR WITH VORTEX

HOSE LENGTH (feet)

AIR PRESSURE RANGE (psig)*

HOSE LENGTH (feet)

AIR PRESSURE RANGE (psig)*

For 886000 Series (3/8" I.D.) air hose and quick-connect coupler assemblies

For 888000 Series (1/2" I.D.) air hose and quick-connect coupler assemblies.

12-1/2 - 25

54-64

12-1/2 - 75

56- 64

50 - 75

59 - 68

100-175

60-68

100 -125

64-73

200 - 225

62-72

150 -175

69 - 78

250 - 300

64-74

200 - 225

73-82

 

 

250 - 300

78-87

 

 

78005 OR 780055 FACEPIECE WITHOUT FLOW CONTROL VALVE COMBINATION AIRLINE AND AIR-PURIFYING RESPIRATORS

HOSE LENGTH (feet)

AIR PRESSURE RANGE (psig)*

HOSE LENGTH (feet)

AIR PRESSURE RANGE (psig)*

For 886000 Series (3/8" I.D.) air hose and quick-connect coupler assemblies

For 888000 Series (1/2" I.D.) air hose and quick-connect coupler assemblies.

12-1/2 - 50

12-35

12-1/2 - 50

11 - 50

75 -125

14-36

75 -150

12-55

150 - 225

17 - 45

175-300

17 -60

250 - 300

20-50

 

 

78006 OR 780065 FACEPIECE WITH FLOW CONTROL VALVE COMBINATION AIRLINE AND AIR-PURIFYING RESPIRATORS

HOSE LENGTH (feet)

AIR PRESSURE RANGE (psig)*

HOSE LENGTH (feet)

AIR PRESSURE RANGE (psig)*

For 886000 Series (3/8" I.D.) air hose and quick-connect coupler assemblies

For 888000 Series (1/2" I.D.) air hose and quick-connect coupler assemblies.

12-1/2 - 50

14-38

12-1/2 - 50

13-35

75 -150

18 - 46

75 -150

15 - 39

175 - 300

20-53

175 - 300

17 -49

* Add at least 1 and no more than 5 psig to any pressure to compensate for the pressure drop created when using a quick-connect coupler at the air source.

Note: For further details refer to the Operating and Maintenance Instruction Manual for each specific product.

Respirator

Supply pressure required in order to achieve the airflow necessary to properly use this respirator

85400A Series - Pressure Demand Airline Respirator

The supply pressure must be set between 70 and 90 psig.

85500A Series - Pressure Demand Airline Respirator

The supply pressure must be set between 70 and 90 psig.

85700 Series - Combination Pressure Demand Airline and Air-Purifying Full Facepiece Respirator

The supply pressure must be set between 78 and 80 psig.

Pressure Demand Airline Pressure Requirements

WSP home page Products page Suppliers page  