For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
||
Convert your North half mask or full facepiece to continuous flow with the CF2007. This breathing tube attaches to North facepiece cartridge connectors, eliminating the need for special adapters or tools. NIOSH approved for use with North 5500, 7700, 5400 and 7600 Series including full face pieces with welding front. |
||
FEATURES |
FUNCTION |
BENEFIT |
Threads onto North cartridge connectors |
• Adapts to North 5500 & 7700 half masks and 5400 & 7600 full facepieces |
• Choose the right facepiece for your work |
Breathing tube hoses are located on worker's back |
• Hoses are out of the way of the work zone |
• Will not interfere with tasks at hand |
Low profile connections |
• When used with half maSk, fits under welding helmets and faceshields |
• Add additional eye and face protection for welding, grinding and other applications |
NIOSH approved for use with 5400 and 7600 with welding adapter |
• May be used for welding applications |
• Provide welders with the increased respiratory |
360 degree swivel on face piece connection |
• Allows full movement of breathing tube without loosening the connection |
• Extra secure and safe - will not come off even during the most strenuous movements |
Soft flexible hoses at top, next to worker's |
• More comfortable |
• Increased worker acceptance |
Choice of two hose I.D. and three brands of couplers |
• Assures breathing air couplers are incompatible with other gases |
• Safer. You stay in compliance with OSHA |
PART NO. |
DESCRIPTION |
PACKAGING |
CF2007 |
Breathing tube with threaded connections to convert North facepieces to supplied air. Includes breathing tube and waist belt |
Each |
CF2401,S |
CF2007 breathing tube with 7600 full facepiece. Sizes medium/large and small |
Each |
![]() |
||
Add the backup and piece of mind of air-purifying cartridges to your supplied air respirator. Use the air-purifying mode for entry, exit and emergency escape from the work environment without exposing workers to harmful contaminants. Ideal when workers must walk out to the air source connection, or would need to disconnect from hoses for a fast and safe escape in an emergency. NIOSH approved for use with 7580P100 filters and 7581P100 organic vapor, P100 filter cartridges. |
||
FEATURES |
FUNCTION |
BENEFIT |
7600 style silicone full facepiece |
• All the great features of the 7600 |
• Increased worker comfort and acceptance |
Available with adjustable flow control valve |
• Allows each worker to increase or decrease air flow |
• Increase flow during stretches of strenuous work |
NIOSH approved with 8404 Welding Conversion Kit |
• Facepiece can be converted for welding applications |
• Welders get the increased respiratory protection of a full facepiece. Use combination cartridges when organic vapors may be present |
Choice of two hose 1.0. and three brands of couplers |
• Assures breathing air couplers are incompatible with other gases |
• Safer. You stay in compliance with OSHA |
PART NO. |
DESCRIPTION |
PACKAGING |
78005,S |
Full Facepiece with breathing tube and cartridge connectors, fixed flow. Sizes medium/large and small |
Each |
78006,S |
Full Facepiece with breathing tube and cartridge connectors, adjustable flow. Sizes medium/large and small |
Each |
WHICH I.D. HOSE IS RIGHT FOR YOUR WORKSITE? |
||
![]() |
||
![]() |
||
| Many workers appreciate the freedom hoods provide, employers appreciate not needing to fit test. Because hoods do not have a facepiece to face seal, you can accommodate workers with facial hair and prescription glasses - plus fit testing is not required. Because hoods are disposable, your clean up is also easier. Ideal for use in extremely dusty environments, for paint spray operations or other applications where respirators get dirty quickly. NIOSH approved with an APF of 1000. | ||
FEATURES |
FUNCTION |
BENEFIT |
GENERAL |
||
Headgear with rachet adjustment |
• Hood moves with worker |
• View is never obstructed, even when turning head left or right |
Assigned Protection Factor of 1000 |
• Highest APF available for non-IDLH environments |
• Workers are protected, even in higher concentrations |
Air deflector directs flow over inside of lens |
• Air is delivered to the front where workers need it most |
• Cooler and more comfortable • Eyes will not dry out • Optimum visibility |
Optional Vortex Tube |
• Temperature can be adjusted to warm or cool plus or minus 30° F (17° C) |
• Increased comfort and worker productivity |
Choice of two hose I.D. and three brands of couplers |
• Assures breathing air couplers are incompatible with other gases |
• Safer. You stay in compliance with OSHA |
DISPOSABLE HOOD. WITHOUT BIB |
||
Elastic at neck covered in cotton |
• Soft and comfortable for extended wear |
• Greater worker acceptance |
Available coated for intermittent splash |
• Added protection, ideal when full chemical suit is not required |
• Increased safety |
DISPOSABLE HOOD. WITH BIB |
||
Inner and outer bib design |
• Inner bib tucks into clothing |
• Directs air flow inside to keep workers cooler |
Outer bib is 12-1/2" (32 cm) long |
• Protects the neck and shoulders |
• Long enough to provide the added protection, not too long to interfere |
PART NO. |
DESCRIPTION |
PACKAGING |
HOOD ASSEMBLY INCLUDES HOOD, HEADGEAR WITH RATCHET ADJUSTMENT, BREATHING TUBE AND WAIST BELT. |
||
8530n |
Hood Assembly with cotton neck |
Each |
8530nB |
Hood Assembly with bib |
Each |
85301S |
Coated Hood Assembly with cotton neck |
Each |
85301SB |
Coated Hood Assembly with bib |
Each |
REPLACEMENT HOODS |
||
85302TA |
Hood with cotton neck seal |
10 per package |
85302TBA |
Hood with bib |
10 per package |
85302SA |
Coated Hood with cotton neck seal |
10 per package |
85302SBA |
Coated Hood with bib |
10 per package |
![]() |
||
The vortex tube provides greater comfort to the worker by cooling or warming the breathing air. It is color coded and simple to use. Air temperature can be adjusted to warm or cool the air by plus or minus 30°F. The vortex tube comes pre-assembled with Hansen (HV), Schrader (SV) or Snap-Tite (STV) couplers. For use with 85300 Hoods for either heating or cooling. |
||
PART NO. |
DESCRIPTION |
PACKAGING |
88600 |
Vortex Tube for 3/8" 1.0. hose - Add suffix to specify Hansen (HV), Schrader (SV), or Snap-Tite (STV) Couplers |
Each |
88800 |
Vortex Tube for 1/2" 1.0. hose - Add suffix to specify Hansen (HV), Schrader (SV), or Snap-Tite (STV) Couplers |
Each |
![]() |
|||||
North ambient air pumps meet continuous flow applications for up to three workers. Pumps are available individually or as part of a complete package. |
|||||
FEATURES |
FUNCTION |
BENEFIT |
|||
Lightweight |
• Portable |
• Flexibility to be used at multiple sites, or stored when not in use |
|||
Uses standard electrical outlet |
• No special wiring required |
• Ready to plug in and use immediately |
|||
Available as a complete supplied air system |
• Includes pump, facepiece or hood, breathing tube, hoses and couplers |
• Assurance you have everything needed for an airline systems |
|||
PART NO. |
DESCRIPTION |
PACKAGING |
|||
AMBIENT AIR PUMP |
|||||
86600 |
1/4 H.P. Ambient Air Pump |
Each |
|||
86610 |
3/4 H.P. Ambient Air Pump |
Each |
|||
86630 |
1 1/2 H.P. Ambient Air Pump |
Each |
|||
Complete Pump Kit. Contains (1) pump, (1) facepiece or hood, (1) breathing tube, (1) 50' hose and (1) set Hansen couplers for connection from breathing tube to hose |
|||||
APPA |
One person Pump Kit, 3/4 H.P. pump, 54001 Full Facepiece and CF2007 breathing tube. |
Each |
|||
APPB |
One person Pump Kit, 3/4 H.P. pump, 85301T Hood, no bib |
Each |
|||
APPC |
One person Pump Kit, 3/4 H.P. pump, 7700 Half Mask and CF2007 breathing tube. Half Mask size medium |
Each |
|||
APPD |
One person Pump Kit, 1/4 H.P. pump, 54001 Full Facepiece and CF2007 breathing tube. |
Each |
|||
APPE |
One person Pump Kit, 1/4 H.P. pump, 7700 Half Mask and CF2007 breathing tube. Half Mask size medium |
Each |
|||
PART NO. |
HORSE POWER |
WEIGHT |
MAX |
# OF PEOPLE |
RECOMMEND HOSES WITH HANSEN COUPLERS |
86600 |
1/4 H.P. |
33 lbs (15 kg) |
5 |
1 |
25' 1/2" I.D., 888025H |
86610 |
3/4 H.P. |
55 lbs (25 kg) |
10 |
2 |
25' 1/2" I.D., 888025H |
86630 |
1-1/2 H.P. |
110 lbs (50 kg) |
20 |
3 |
25' 1/2" I.D., 888025H |
The Occupational Safety and Health Administration (OSHA) published new Assigned Protection Factors (APF) for all respirators in September, 2006. The new APF Table assigns two possible protection factors for supplied air and powered air-purifying hoods. All hoods now have an APF of 25 unless conditions outlined in footnote 4 from OSHA's Assigned Protection Factor Table are met. FOOTNOTE FROM OSHA TABLE ON ASSIGNED PROTECTION FACTORS |
|||
RESULTS |
|||
SERIES |
PART NO. |
DESCRIPTION |
SWPF RESULTS |
TESTED BY NORTH |
|||
Primair Plus Series |
PA111 |
Hood Assembly with Bib |
>1,000 |
PA112 |
Replacement Hood with Bib |
||
PA121 |
Coated Hood Assembly with Bib |
||
PA122 |
Replacement Coated Hood with Bib |
||
Primair FM 200 Series |
PA201 E01 |
Hood Assembly with E2 Hard Hat |
>1,000 |
PA201 P01 |
Hood Assembly with P2N Hard Hat |
||
PA231E01 |
Hood Assembly with Carbtex, E2 Hard Hat |
||
PA231P01 |
Hood Assembly with Carbtex, P2N hard Hat |
||
PA202 |
Replacement Hoods to Primair FM 200 Series |
||
Primair FM 300 Series |
PA301 |
Hood Assembly |
>1,000 |
PA331 |
Hood Assembly with Carbtex |
||
PA302 |
Replacement Hoods for Primair FM 300 Series |
||
85300 Series |
8530n |
Hood Assembly with Cotton Neck |
>1,000 |
85302TA |
Replacement Hood with Cotton Neck |
||
85301S |
Coated Hood Assembly with Cotton Neck |
||
85302SA |
Replacement Coated Hood with Cotton Neck |
||
TESTED BY LIVERMORE LABS DURING ORIGINAL RESEARCH PROJECT |
|||
85300 Series |
8530nB |
Hood Assembly with Bib |
>1,000 |
85302TBA |
Replacement Hood with Bib |
||
85301SB |
Coated Hood Assembly with Bib |
||
85302SBA |
Replacement Coated Hood with Bib |
||
![]() |
||
The North 85400 and 85500 Series PDAR respirators feature North's popular silicone full facepiece with dual flange sealing area and superior optics. Models with escape cylinders feature slim 5 minute bottles. Use only one for 5 minutes of escape, or two bottles for a total of ten minutes of escape. Both series are NIOSH approved, and the 85500 may also be used in IDLH environments. |
||
FEATURES |
FUNCTION |
BENEFIT |
Available without escape, with 5 minute |
• Select the right PDAR for your work environment |
• 85400 without escape to meet your budget |
85500 can accommodate one or two 5 minute cylinders |
• Can be converted to 5 or 10 minute units |
• Versatility. Use 5 minutes when weight is the critical |
"Leap Frog" capability |
• Allows user to connect to second air source before disconnecting to first source |
• No interruption in air supply |
Ambidextrous |
• Cylinders can be worn on left or right side |
• Cylinders do not interfere with left handed workers |
Escape cylinders can be taken off the belt, without interruption of air supply to facepiece |
• Allows cylinders to be carried or dropped between the legs for a low profile |
• Workers can safely enter or escape from a confined space or other constricted entrance without loss of air |
PART NO. |
DESCRIPTION |
PACKAGING |
85401,S |
PDAR without escape cylinders, no escape cylinder option. Sizes medium/large and small |
Each |
85501,S |
PDAR without escape cylinders, with option to add escape cylinders. Sizes medium/large and small |
Each |
85505,S |
PDAR with one 5 minute escape bottle. Sizes medium/large and small |
Each |
85510,S |
PDAR with two 5 minute escape bottles for total 10 minute escape. Sizes medium/large and small |
Each |
85525 |
5 minute escape bottle for 85501, 85505 and 85510 |
Each |
![]() |
||
The 85785 PDAR incorporates cartridge connectors for P100 filters so it can be used for entry, exit and escape from non-IDlH environments. This respirator is ideal where there are high particulates and workers need to travel to access the supplied air source. NIOSH approved for use with 7580P00 filters. |
||
FEATURES |
FUNCTION |
BENEFIT |
Silicone facepiece |
• All the features of the popular 7600 series full facepiece |
• Increased worker comfort and acceptance |
Cartridge Connectors |
• Use 7580P100 for entry, exit and emergency escape |
• Allows PDAR to be used when workers need to walk distance to air supply |
PART NO. |
DESCRIPTION |
PACKAGING |
85785,S |
PDAR with cartridge connectors. Sizes medium/large and small |
Each |
![]() |
||
North offers this compact compressor for use in confined space or in other IDlH environments. This portable compressor will connect two workers using pressure demand respirators equipped with 5 or 10 minutes emergency egress. Warning alarm of 84db at 100 feet alerts workers of low pressure or power failure. The compressor will supply up to 100 psi. |
||
FEATURES |
FUNCTION |
BENEFIT |
Compact |
• Can be transported |
• Can be used at remote locations |
Compressed air system |
• Supplies up to 100 psi |
• Use with PDAR |
Warning alarm |
• Sounds at 84 dB from 100 feet away |
• Alerts workers of low pressure or a power failure |
PART NO. |
DESCRIPTION |
PACKAGING |
86620 |
Compressor |
Each |
![]() |
|||
North hoses are available for both 3/8" I.D. and 1/2" I.D. in 12-1/2', 25', 50', and 100' lengths. North offers Hansen, Schrader and Snap- Tite Quick Connect Couplers for connecting the hose to the facepiece or breathing hood, and the air source. |
|||
PART NO. |
DESCRIPTION |
||
AIR SUPPLY HOSES |
|||
886012 |
12-1/2 ft. Air Hose, 3/8" I.D. |
||
886025 |
25 ft. Air Hose, 3/8" I.D. |
||
886050 |
50 ft. Air Hose, 3/8" I.D. |
||
886100 |
100 ft. Air Hose, 3/8" I.D. |
||
888012 |
12-1/2 ft. Air Hose, 1/2" I.D. |
||
888025 |
25 ft. Air Hose, 1/2" I.D. |
||
888050 |
50 ft. Air Hose, 1/2" I.D. |
||
888100 |
100 ft. Air Hose, 1/2" I.D |
||
| Description | Hansen Part No. | Snap-Tite Part No. | Schrader Part No. |
QUICK CONNECT COUPLERS FOR CONNECTING AIR SUPPLY HOSE TO HOOD OR FACEPIECE |
|||
Male plug with bushing for 3/8" NPT thread |
880161H |
880161ST |
880161S |
Female coupler for 3/8" I.D. Hose |
880040H |
880040ST |
880040S |
Female coupler for 1/2" I.D. Hose |
880060H |
880060ST |
880060S |
Coupler assembly for 3/8" I.D. Hose |
88600H |
88600ST |
88600S |
Coupler assembly for 1/2" I.D. Hose |
88800H |
88800ST |
88800S |
QUICK CONNECT COUPLERS FOR CONNECTING AIR SUPPLY HOSE TO AIR SOURCE |
|||
Male plug, for connecting to 3/8" I.D. Hose |
880141H |
880141ST |
880141S |
Male plug with bushing, for connecting to 1/2" I.D. Hose |
880161H |
880161ST |
880161S |
To attach coupler to air source Female coupler for air source with 1/4" NPT male thread |
880040H |
880040ST |
880040S |
Female coupler for air source with 1/4" NPT female thread |
880041H |
880041ST |
880041S |
Female coupler for air source with 3/8" NPT male thread |
880060H |
880060ST |
880060S |
Female coupler for air source with 3/8" NPT female thread |
880061H |
880061ST |
880061S |
HOSE ASSEMBLIES TO COMBINE 3/8" 1.0. HOSE WITH COUPLER ASSEMBLY FOR CONNECTING THE AIR SUPPLY HOSE TO HOOD OR FACEPIECE |
|||
12 1/2 ft. Air Hose, 3/8" I.D. |
886012H |
886012ST |
886012S |
25 ft. Air Hose, 3/8" I.D. |
886025H |
886012ST |
886012S |
50 ft. Air Hose, 3/8" I.D. |
886050H |
886050ST |
886050S |
100 ft. Air Hose, 3/8" I.D. |
886100H |
886100ST |
886100S |
Make sure that the air supply hose is connected to a source of air meeting the most recent requirements for Grade D gaseous air as described in the ANSI/eGA 7.1 Commodity Specification for Air and containing not less than 19.5% oxygen by volume at sea level. |
|||
CONTINUOUS FLOW AIRLINE PRESSURE REQUIREMENTS |
|||
CFlOOO SERIES AIRLINE RESPIRATOR |
|||
HOSE LENGTH (feet) |
AIR PRESSURE RANGE (psig)* |
HOSE LENGTH (feet) |
AIR PRESSURE RANGE (psig)* |
For 886000 Series (3/8" I.D.) air hose and quick-connect coupler assemblies. |
For 888000 Series (1/2" I.D.) air hose and quick-connect coupler assemblies. |
||
12-1/2 - 25 |
7 -19 |
12-1/2 - 25 |
7 -19 |
50 - 75 |
9 -23 |
50 - 75 |
8- 21 |
100 -150 |
12-28 |
100 -150 |
9-22 |
175 - 300 |
17 -35 |
175 - 300 |
10- 25 |
85300 SERIES - CONTINUOUS FLOW AIRLINE HOOD RESPIRATOR |
|||
HOSE LENGTH (feet) |
AIR PRESSURE RANGE (psig)* |
HOSE LENGTH (feet) |
AIR PRESSURE RANGE (psig)* |
For 886000 Series (3/8" I.D.) air hose and quick-connect coupler assemblies |
For 888000 Series (1/2" I.D.) air hose and quick-connect coupler assemblies. |
||
12-1/2 - 25 |
9- 20 |
12-1/2 - 75 |
9-16 |
50 - 75 |
13 - 26 |
100-175 |
12 - 25 |
100 -125 |
16 - 35 |
200 - 225 |
14- 30 |
150 -175 |
20-41 |
250 - 300 |
16 - 33 |
200 - 225 |
23-47 |
|
|
250 - 300 |
26-53 |
|
|
8Sl00 SERIES - CONTINUOUS FLOW AIRLINE HOOD RESPIRATOR WITH VORTEX |
|||
HOSE LENGTH (feet) |
AIR PRESSURE RANGE (psig)* |
HOSE LENGTH (feet) |
AIR PRESSURE RANGE (psig)* |
For 886000 Series (3/8" I.D.) air hose and quick-connect coupler assemblies |
For 888000 Series (1/2" I.D.) air hose and quick-connect coupler assemblies. |
||
12-1/2 - 25 |
54-64 |
12-1/2 - 75 |
56- 64 |
50 - 75 |
59 - 68 |
100-175 |
60-68 |
100 -125 |
64-73 |
200 - 225 |
62-72 |
150 -175 |
69 - 78 |
250 - 300 |
64-74 |
200 - 225 |
73-82 |
|
|
250 - 300 |
78-87 |
|
|
78005 OR 780055 FACEPIECE WITHOUT FLOW CONTROL VALVE COMBINATION AIRLINE AND AIR-PURIFYING RESPIRATORS |
|||
HOSE LENGTH (feet) |
AIR PRESSURE RANGE (psig)* |
HOSE LENGTH (feet) |
AIR PRESSURE RANGE (psig)* |
For 886000 Series (3/8" I.D.) air hose and quick-connect coupler assemblies |
For 888000 Series (1/2" I.D.) air hose and quick-connect coupler assemblies. |
||
12-1/2 - 50 |
12-35 |
12-1/2 - 50 |
11 - 50 |
75 -125 |
14-36 |
75 -150 |
12-55 |
150 - 225 |
17 - 45 |
175-300 |
17 -60 |
250 - 300 |
20-50 |
|
|
78006 OR 780065 FACEPIECE WITH FLOW CONTROL VALVE COMBINATION AIRLINE AND AIR-PURIFYING RESPIRATORS |
|||
HOSE LENGTH (feet) |
AIR PRESSURE RANGE (psig)* |
HOSE LENGTH (feet) |
AIR PRESSURE RANGE (psig)* |
For 886000 Series (3/8" I.D.) air hose and quick-connect coupler assemblies |
For 888000 Series (1/2" I.D.) air hose and quick-connect coupler assemblies. |
||
12-1/2 - 50 |
14-38 |
12-1/2 - 50 |
13-35 |
75 -150 |
18 - 46 |
75 -150 |
15 - 39 |
175 - 300 |
20-53 |
175 - 300 |
17 -49 |
* Add at least 1 and no more than 5 psig to any pressure to compensate for the pressure drop created when using a quick-connect coupler at the air source. |
|||
Note: For further details refer to the Operating and Maintenance Instruction Manual for each specific product. |
|||
Respirator |
Supply pressure required in order to achieve the airflow necessary to properly use this respirator |
85400A Series - Pressure Demand Airline Respirator |
The supply pressure must be set between 70 and 90 psig. |
85500A Series - Pressure Demand Airline Respirator |
The supply pressure must be set between 70 and 90 psig. |
85700 Series - Combination Pressure Demand Airline and Air-Purifying Full Facepiece Respirator |
The supply pressure must be set between 78 and 80 psig. |
| WSP home page | Products page | Suppliers page | |
| Respiratory Protection | North Respirator Index | Previous North Respirator Page | Next North Respirator Page |