| Supplied air respirators are used to provide air to workers in contaminated atmospheres found in paint spraying, sand blasting, asbestos abatement and other applications. They are usually supplied by oil-lubricated air compressors. Contaminants such as oil, rust, water, dirt, scale and deadly carbon monoxide gas can find their way into the intake of the compressor, or be produced by the compressor itself, turning a protective breathing apparatus into a hazardous accessory. Even oil-less type compressors can intake carbon monoxide and other contaminants. Chemicals found in various paints and other adhesives and solvents require the use of supplied air respirators. In many instances, the use of cartridge type negative pressure respirators are no longer "permissible practices". (Consult NIOSH "Pocket Guide to Chemical Hazards" for information regarding the use of supplied air type respirators) |
| OSHA Regulations: OSHA states in 29 CFR1910.134(d) that air quality for "Breathing air shall meet at least the requirements of the specification for Grade D breathing air as described in Compressed Gas Association Commodity Specification G-7.1-1989...Compressors shall be constructed and situated so as to avoid entray of contaminated into the system and suitable in-line air purifying sorbent beds and filters to further assure breathing air quality". The Compressed Gas Association (according to G-7.1-1989) lists the following maximum allowable contaminant levels in Grade D air: Carbon Monoxide - 10 ppm Carbon Dioxide - 1000 ppm Condensed Hydrocarbons - 5 mg/m3 |
| Don't Just Filter...Purify with MST's Low Temperature Catalyst to Remove CO
MST's unique LT CAT low temperature catalyst offers significant benefits over all other CO removal systems. Because MST uses a precious metal catalyst, the Respiratory Protector series Breathing Air Purification Systems convert CO to Carbon Dioxide without the limitations you find with every other CO removal system on the market today. |
The four stages of air purification with MST purifiers are:
WARNING: MST's Air Purification Systems will not increase the oxygen content of an air supply and should not be used when air entering the system is oxygen deficient. |
![]() |
![]() |
||
|
|||
| These are the only truly portable, continuous-use CO removal systems available. Operators enjoy extra freedom while breathing cleaner, humidified air. In addition to weighing a mere 19 or 31 lbs., these Respiratory Protector systems come complete with CO monitor standard on all models. You can choose between the Model 5701 CO and oxygen monitor or the Model 5700 monitor with LCD display of CO in ppm. | |||
| Specifications | Model RP010 | Model RP050 | Model RP008 |
| Rated air flow (max) @ 100 psi | 10 SCFM | 50 SCFM | 8 SCFM |
| Operating pressure | 100 psig dynamic | 100 psig dynamic | 100 psig dynamic |
| Inlet pressure (max) | 150 psig static | 150 psig static | 150 psig static |
| Outlet pressure range | 0-125 psig | 0-125 psig | 0-125 psig |
| Operating temp. range | 68-150ºF | 68-150ºF | 68-150ºF |
| Operating relative humidity (inlet air - non condensing) | 30-100% RH | 30-100% RH | 30-100% RH |
| Outside dimensions | 13.5"L x 12.87"W x 6"D | 23.25"L x 20.75"W x 9"D | 8.5"L x 7"W x 4"D |
| Weight (including monitor) | 19 lbs. | 31 lbs. | 3.5 lbs. |
| Replacement filter set | RCRP010 | FX050 | 8026901 |
![]() |
|||||
| Like all Respiratory Protector systems, MST's wall-mount units employ LT CAT low-temperature catalyst, removing CO while eliminating the cost of desicant dryers and providing a continuous stream of moist, comfortable breathing air. We offer wall-mount systems with capacities from 10 to 1000 SCFM. If space considerations allow, our Twin 50 Model offers significantly lower replacement catalyst cartridge costs for larger systems. Respiratory Protector wall-mount systems are available with four types of electrochemical carbon monoxide monitors. Model 2002 has a LED display for CO and comes in a heavy duty enclosure. Model 5701 monitors both CO and oxygen. The 5700 has an LCD display for CO in ppm. The model 5800 has green and red LED indicator lights for CO. |
|||||
| Specifications | Model RP010 | Model RP050 | Model RP050 (twin 50) |
Model RP100 | Model RP200 |
| Rated air flow (max) @ 100 psi | 10 SCFM | 50 SCFM | 100 SCFM | 100 SCFM | 200 SCFM |
| Operating pressure | 100 psig dynamic | 100 psig dynamic | 100 psig dynamic | 100 psig dynamic | 100 psig dynamic |
| Inlet pressure (max) | 150 psig static | 150 psig static | 150 psig static | 150 psig static | 150 psig static |
| Outlet pressure range | 1-125 psig | 1-125 psig | 1-125 psig | 1-125 psig | 1-125 psig |
| Operating temp. range | 68-150ºF | 68-150ºF | 68-150ºF | 68-150ºF | 68-150ºF |
| Operating relative humidity (inlet air - non condensing) |
30 - 100% RH | 30 - 100% RH | 30 - 100% RH | 30 - 100% RH | 30 - 100% RH |
| Outside dimensions | 24"L x 18"W x 5.75"D | 23.25"L x 20.75"W x 9"D | 48"L x 24"W x 5.75"D | 24"L x 36"W x 7.75"D | 36"L x 36"W x 7.57"D |
| Weight (including monitor) | 18 lbs. | 31 lbs. | 53 lbs. | 86 lbs. | 125 lbs. |
| Replacment filter set | RCRP010 | FX050 | FX050/2 | FX100 | FX200C |
![]() |
||
![]() |
||
| MST's four stage filtration system is standard on every portable model and provides extra protection for longer filter life and better filtering capabilities than most other comparable filtering systems. Prefilter dual stage element removes particulates down to 0.3 microns and coalesces liquids down to 0.75 microns, at an efficiency rating of 99.97% (D. O. P.) A carbon monoxide monitor is available on every breathing air filter system we make to continuously monitor your breathing air for compliance with applicable standards. Monitors offer digital display with both audio and visual alarms. All monitors utilize an electrochemical sensor to measure CO levels. The MST Breathing Air Panel Series can be supplied with or without carbon monoxide monitors, depending on end users' specific situation. This option is available upon request. |
||
| Specifications | Model BA050 | Model BA100 |
| Rated air flow (max) @ 100 psi | 50 SCFM | 100 SCFM |
| Operating pressure | 100 psig dynamic | 100 psig dynamic |
| Inlet pressure (max) | 150 psig static | 150 psig static |
| Outlet pressure range | 0-125 psig | 0-125 psig |
| Operating temp. range | 68-150ºF | 68-150ºF |
| Outside dimensions | 20.5"L x 16.75"W x 8.5"D | 23.5"L x 20.75"W x 9"D |
| Weight (including monitor) | 25 lbs. | 36 lbs. |
| Replacement filter set | FB050 | FB100 |
![]() |
![]() |
||||
| For larger capacity requirements, MST's wall mount systems provide extra activated charcoal to remove particulates and coalesce liquids. Breathing air wall mount systems are available with four types of electrochemical carbon monoxide monitors. Model 2002 has a LED display for CO and comes in a heavy duty enclosure. The model 5701 monitors both CO and oxygen. The 5700 has an LCD display for CO in ppm. The model 5800 has green and red LED indicator lights for CO | |||||
| Specifications | BA020 | BA50 | BA100 | BA200 | BA600 |
| Rated air flow (max) @ 100 psi | 20 SCFM | 50 SCFM | 100 SCFM | 200 SCFM | 600 SCFM |
| Operating pressure | 100 psig dynamic | 100 psig dynamic | 100 psig dynamic | 100 psig dynamic | 100 psig dynamic |
| Inlet pressure (max) | 150 psig static | 150 psig static | 150 psig static | 150 psig static | 150 psig static |
| Outlet pressure range | 0-125 psig | 0-125 psig | 0-125 psig | 0-125 psig | 0-125 psig |
| Operating temp range | 68-150ºF | 68-150ºF | 68-150ºF | 68-150ºF | 68-150ºF |
| Outside dimensions | 16"L x 16"W x 5"D | 24"L x 18"W x 5.5"D | 24"L x 24"W x 5.5"D | 36"L x 36"W x 17"D | 36"L x 36"W x 17"D |
| Weight (including monitor) | 10 lbs. | 18 lbs. | 25 lbs. | 72 lbs. | 87 lbs. |
| Replacement filter set | FB020 | FB050 | FB100 | FB200 | FB600 |
| Low Pressure Alarm System | |
![]() |
|
| This is an air distribution system that will alarm when the supplied air falls below a preset air pressure setting. When the inlet air pressure falls below the preset level specified in the model number, a pressure switch connects the internal 9 volt battery to the alarm (rated 119 dB(A). The alarm will continue to operate until the pressure in the system exceeds the preset level. | |
| Specifications | 8021101-(XX) |
| Unit model designation | 8021101_PSIG (+/-5 PSIG) |
| Power requirements | Internal 9 volt transistor battery (Eveready No. 522 or equal) |
| Standard pressure set alarm point | 83.75 and 65 PSIG (+/-5) |
| Operating temperature | 14º to 122ºF |
| Maximum inlet pressure | 150 psig static |
| Operating pressure | 100 psig dynamic |
| Inlet fitting supplied | (1) plug, 3.8" II x 3/8" MPT |
| Outlet fittings supplied, standard | (4) quick-disconnect, 1/4" II x 3/8" MPT |
| Optional | (4) quick-disconnect, 1/4" schrader x 3/8" MPT (MST P.N. 80166) |
| Size | 10.75"W x 9.75"H x 7"D |
| Weight (with fittings) | 7 lbs. |
| Point of Attachment Panel | |
![]() |
|
| The point of attachment panel removes any contaminants introduced between the purification/filtration panel and the point of attachment panel | |
| Specifications | Model 8042601 |
| Rated air flow | 133 SCFM (rated on dynamic pressure at 100 psi) |
| Size | 16"L x 16"W x 5.75"D |
| Weight | 11 lbs. |
| Maximum inlet pressure | 125 psig |
| Outlet pressure range | 0-125 psig |
| Replacement filter | 80066 |
| Automatic Shut-off / Back-up Diverter Device (ASODD) | |
![]() |
|
| MST's Automatic Shut-Off Diverter Device, (ASODD) is designed to supply compressed air from a main source and divert to a secondary air source when an outside signal has energized the ASODD's solenoid valve. The main air source enters at 1/2" FPT and exits at 1/2" FPT. The ASODD's power requirements is 120 VAC and can be supplied through a supplied power cord. When an outside signal source energizes the ASODD's switching relay through the signal cord/plug, the ASODD's solenoid valve shuts off the main air source and allows the secondary air source to flow to the outlet. When the signal source de-energizes, the air flow will be diverted back to the main air source. The signal source can be any 1.0 amp maximum at 12 VDC. | |
| Specifications | Model 8026201 ASODD |
| Size | 16"L x 13"W x 7"D |
| Weight | 12 lbs. |
| Temperature range | -20º to 130ºF |
| Main air supply max inlet pressure | 150 psig |
| Secondar air supply pressure range | Equal or greater than main air supply and not greater than 150 psig |
| Response time | 9 ms at 90 psig |
| Main power supply | 120 VAC |
| Switching signal | 1.0 amp max at 12 VDC |
| Air Shut-Off Device (not shown) | |
| The MST Model 8010501 Air Shut-Off Device (ASOD) is a small, compact valving system designed to interrupt the air supply to MST's Breathing Air Filtration and/or Purification Systems should the carbon monoxide monitoring system in the Filtration and/or Purification system go in an alarm condition | |
| Specifications | Model 8010501 ASOD |
| Power requirements | 12 VDC |
| Main voltage | 0.17 amp |
| Maximum inlet pressure | 150 psi |
| Maximum flow rate | 100 SCFM |
| Operating temperature range | -20º to 120ºF |
![]() |
||
| MST offers CO air line monitors with LCD's, all employing an electrochemical sensor. You can select between a flow meter type or pressure regulator type, in 110 VAC or 12 VDC operation. All systems let you check carbon monoxide levels througout your compressed air system. | ||
| Specifications | 5700-1 (110 VAC) or 5700-2 (12 VDC) | 5700-3 (110 VAC) or 5700-4 (12 VDC) |
| Size | 10.75"W x 9.75"H x 7"D | 13.25"W x 11"H x 5.5"D |
| Weight | Less than 7 lbs. | Less than 7 lbs. |
| Operating pressure (max) | 100 psi max. (flow meter to be set at 1 SCFH) | 100 psi max. |
| Sensor type | Electrochemical | Electrochemical |
| Range | 0-199 ppm CO | 0-199 ppm CO |
| Accuracy | +/- 5% of reading | +/- 5% of reading |
| Alarm type | Piezoelectric ~85 dB(A) at 1 ft. (Optional 119 dB(A) at 10 ft.) |
Piezoelectric ~85 dB(A) at 1 ft. (Optional 119 dB(A) at 10 ft.) |
| Alarm level setting | User adjustable factory setting: 10 ppm (5 ppm if specified) | User adjustable factory setting: 10 ppm (5 ppm if specified) |
| Air sample | Non filtered | Regulated / filtered |
| Other features | Protective enclosure, Adjustable sample flow meter, External remote alarm jack, Low battery indicator, Red alarm indicator, 9 VDC battery back up | Protective enclosure, External remote alarm jack, Low battery indicator, Red alarm indicator, 9 VDC battery back up |
| LCD CO / O2 Airline Monitors | |
| MST offers two models, each employing an electrochemical sensor. You can select between 110 VAC or 12 VDC operation. Either let you check carbon monoxide and oxygen levels throughout your compressed air system. | |
| Specifications | 5701-1 (110 VAC) or 5701-2 (12 VDC) |
| Size | 13.25"W x 11"H x 5.5"D |
| Weight | 7 lbs. |
| Operating pressure (max) | 100 psi |
| Sensor type | Electrochemical |
| Range | 0-199 ppm CO |
| Accuracy | +/- 5% of reading |
| Alarm type | Piezoelectric ~85 dB(A) at 1 ft. (Optional 119 dB(A) at 10 ft.) |
| Alarm level setting | User adjustable factory setting: 10 ppm (5 ppm if specifed); 19.5% O2 |
| Ambient operating temp. range | 32º to 104ºF |
| Air sample | Regulated / Filtered |
| Other features | Protective enclosure, External remote alarm jack, Low battery indicator, Red alarm indicator, 9 VDC battery back up |
| CO Monitoring System | |
| MST's airline carbon monoxide monitoring system is designed to take a continuous air source sample from the compressed air line and monitor for levels of carbon monoxide. If pre-set alarm level is reached, a visual and audible alarm will be energized and a red alarm indicator will light. The system is housed in a corrosion resistant carrying case. | |
| Specifications | Model 5800 |
| Size | 10.5"W x 9.5"H x 4/75"D |
| Weight | 5.5 lbs. |
| Operating pressure (max) | 100 psig dynamic (flow meter is set to 1 SCFH) |
| Sensor type | Electrochemical |
| Range | 0-199 ppm CO |
| Accuracy | +/- 5% of reading |
| Alarm type | Piezoelectric ~85 dB(A) at 1 ft. (Optional 119 dB(A) at 10 ft.) |
| Alarm level setting | User adjustable factory setting: 10 ppm (5 ppm if specified) |
| Ambient operating temp. range | 32º to 104ºF |
| Other features | Adj. sample flow meter, Red alarm indicator, 9 VDC battery back up |
![]() |
|
| The model 2002 toxic gas monitor system is a cost effective single point, fixed monitoring system for gas analysis. The monitor is housed in a NEMA 12 enclosure with clear front panel and digital readout, and is designed to operate in forced air, diffusion or remote sensing modes, allowing the instrument to fit many applications for gas detection in non-flammable atmospheres. Designed originally to meet OSHA CFR 29 1910.134 standards for the measurement of carbon monoxide in Grade D breathing air, the 2002 has been upgraded to meet not only Grade D breathing air application; but applications such as ambient air monitoring in factories, parking garages, boiler rooms, or other areas where single point gas detection is required. The sensor can be located directly in the housing or installed in a remote sensing head. The 2002 is a fully enclosed monitor complete with digital readout, dual stage alarm relays and a clear front panel for easy viewing of gas conditions. Calibration ports are secured behind the clear panel for easy access. Alarm relay contacts and sensor chamber are secured behind the lower access panel, allowing full service and wiring of the system while mounted ready for use. Audible and visual alarms can be mounted on the inside or outside of the housing, or located remotely according to user needs. |
|
| Specifications | Model 2002 |
| Dimensions | 8"W x 6.2"L x 3.7"D |
| Weight | 2.2 lbs. Monitor with diffusion sensor only |
| Enclosure | NEMA 12 rated with latching cover |
| Display | 11 mm LCD; single line display |
| Accuracy | +/- 5% of reading |
| Measuring range: CO, H2S, SO2, CL2 Range O2 Range |
0-999 ppm in 1 ppm increments 0-25% in 1% increments |
| Power supply | 12 VDC, 120 / 240 VAC |
| Alarm relays | Two, non-voltage, normally open and normally closed contacts |
| Maximum relay load (Dry contact only) | 5 amp 250 VAC, 5 amp 30 VDC |
| Sensor type | Electrochemical |
| Rating | Non-intrinsic safe design, NEMA 4 rating only |
![]() |
|
| Affordable compact toxic gas and oxygen detection monitors, designed for field use. They are accurate, rugged, reliable, water and EMI resistant and easy to read. Unlike models with digital displays, the MST monitors utilize a unique series of amber and red lights, along with audible alarms, to warn of increasingly dangerous levels of toxic gases or inadequate levels of oxygen. In addition, the MST TS6500-CO, the TS6500-H2S and TS6500-O2 are virtually maintenance free, and guaranteed for one year. Once turned on, the monitors are designed to remain on for a full year with the only user maintenance being periodic calibration. As the monitors contain no field serviceable parts, they should be returned to MST after one year for service and a new one year warranty. |
|
| Specifications | TS6500 Series |
| Size | 4.25"W x 2.5"L x 1"D |
| Weight | 3.8 oz. |
| Alarm/display levels | CO: 15, 35, 50, 100 ppm H2S: 5, 10, 15, 30 ppm O2: 16, 18, 19.5, 21, 22% |
| Sensors | Electrochemical |
| Battery | 3.5 VDC lithium - factory installed |
![]() |
![]() |
| 8008403 Remote alarm offers added protection (119 dB(A) in noisy environments. (standard on all S1 models) |
8008503 Remote strobe offers added visual protection in high noise areas. Can only be used when monitor is powered by optional power accessories |
![]() |
![]() |
| 8039601 Air horn alarm system is used for explosive atmospheres. Operating pressure 20-30 psi using a 100 psi regulator |
Y-Jack adapter easily allows operating two external devices |
![]() |
![]() |
| 8025601 External relay assembly provides normally open or normally closed terminals to activate or deactivate an external device |
8022801 Electronic filter life timer records actual filter use for easy maintenance scheduling |
![]() |
![]() |
| 8021601 Humidifier prefilters |
8009002 (66 SCFM) and 8010401 (133 SCFM) External coalescing prefilters |
![]() |
![]() |
| 8023301 Low pressure warning system to alert operators when inlet air pressure falls below safe levels |
MST monitor power accessories: 80247, 120 VAC adapter 8013501 Rechargeable battery system 80123 12 VDC battery adapter (9 volt replaceable batteries are standard) Provides up to 250 hour of continuous operation |
![]() |
![]() |
| 80123 12 VDC battery adapter with red and black clips, 6 ft. black cord and a 2.5 mm center positive (DC) inside socket |
8003101 Small calibration kit (10 calibrations) and 8003102 large calibration kit (50-60 calibrations) available for MST monitor. Includes zero and span gases, regulator, calibration tool, case and instructions |
![]() |
|
| Replacement filter kits include all elements for complete filter change. Be sure to have correct part number for your unit. Contact local distributor or MST for assistance | |
![]() |
|
| Ambient air compressor MST, Inc. now has available a portable ambient air compressor for painters who do not have enough volume in their current compressed air system to accommodate the additional load required to operate a respirator. MST's Fresh-Air pump is small, quiet, lightweight and ready to supply clean breathing air to one worker. The pump comes with an on-off switch and is wired for 120 VAC power, however, the pump can also be wired to operate from 220 VAC. The pump has replaceable filters to keep your air clean and help protect your workers from breathing contaminated air. Intake hose extensions are also available, if the pump cannot easily be placed in a non-contaminated atmosphere, to assure clean breathable air. |
|