For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
Ultra Filter Respirators are full-face, single cartridge respirators, designed for protection against particulate hazards, especially in the nuclear and abatement industries. The Ultra Filter Respirator uses a compact round filter cartridge that has a large effective filter area to provide low breathing resistance and high loading capacity. The round Ultra Filter Cartridge has a P100 classification for high efficiency protection against oil and non-oil containing hazards or hazard specific standards requiring HEPA filters, such as the Lead and Asbestos Standards |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
The OptimAir MM Powered Air Purifying Respirator (PAPR) is designed for work in abatement projects. The unit filters particulates and provides respirable air directly to the Ultravue or Ultra Elite Facepieces. Because it does not have a breathing tube, the unit is more compact than other PAPRs, enhancing the user's maneuverability and simplifiying decontamination. The unit designed for long life, low maintenance, maneuverability, comfort and ease of decontamination. The Ultravue facepiece and Type H OptiFilter XL cartridge are interchangeable with other MSA respirators. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
The OptimAir 6A Powered Air Purifying Respirator (PAPR) provides respiratory protection by filtering contaminants from ambient air and providing air flow to either a facepiece or hood (with HEPA filters only) at a rate equal to or exceeding NIOSH standards. It can be used with an entire family of filters, chemical cartridges and combination cartridges for protection against particulates, toxic gases and vapors, or a combination of these hazards. It requires two filters. The unit is available with full or half-mask facepieces, or a hood. Applications include hazardous materials cleanup, asbestos and lead paint abatement, chemical processing, foundry, smelter and coke oven applications and nuclear facilities work. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
OptimAir® Replacement Parts and Accessories
| Facepieces for OptimAir 6A | ||||||
| Black Hycar | Black Silicone | |||||
| Description | Small | Medium | Large | Small | Medium | Large |
| Ultravue | 471218 | 457126 | 471230 | 480251 | 480247 | 480255 |
| Comfo | 480127 | 480122 | 480132 | 480130 | 480125 | 480135 |
| Comfo Welder's | 484204 | 484198 | 484210 | 484206 | 484200 | 484212 |
| Ultra Elite Facepieces | ||||||
| Black Hycar | Black Silicone | |||||
| Description | Small | Medium | Large | Small | Medium | Large |
| SoftFeel Black | 810223 | 810151 | 810295 | 810231 | 810159 | 810303 |
| Replacement Hoods | |
| Tyvek Hood Shell only | 488721 |
| Tyvek Hood Assembly | 486485 |
| Breathing Tube Assemblies | |
| For tight fitting facepieces, 30" | 486364 |
| For Tyvek Hood | 481980 |
| 36" Breathing Tube for tight fitting facepieces | 492197 |
| Flow Tester
The Flow Tester is a thin plate orifice meter for testing the volumetric flow rate delivered by an MSA OptimAir PAPR |
|
| Flow Tester | 488903 |
| Support Belts for PAPRs
MSA offers polyurethane coated nylon and polychloride belts that are easy to decontiminate. If decontamination is not a factor, users may opt for an uncoated nylon web belt. Optional Shoulder suppport strap may be used with PAPR Belts. |
|
| Polyurethane coated nylon support belt | 492827 |
| PVC support belt | 473902 |
| Web support belt, uncoated | 9961 |
| Shoulder support strap | 803903 |
| Field Test Unit
Quickly evaluates the electrical components of an OptimAir 6A PAPR |
|
| Field Test Unit | 468486 |
| Protective Cover
Protects PAPR from water (such as in Asbestos decontamination shower) or particulate contamination |
|
| Package of 5 for OptimAir 6A | 808494 |
| Flow Check Devices
MSA flow check devices allow users of PAPRs to quickly and conveniently verify that their unit is providing the required air flow |
|
| E-Z Chek Flow Indicator | 800340 |
| Flow Check Meter | 487995 |
| Adapter for Flow Check Meter for use with Tyvek Hoods | 489999 |
| Adapter for Flow Check Meter for use with OptimAir MM PAPR | 491046 |
| Ordering Info for OptiFilter XL / OptiFilter Cartridges for OptimAir 6A PAPR | ||||||
| MSA Purifying Element | Protect Code | Respiratory Hazards | Part No. | In Box | NIOSH App. No. |
|
| OptiFilter XL Type H | HE | Particulate filter (99.97% filter efficiency). Effective against all particulate aerosols |
496080 | 50 | TC-21C-512 Ultravue TC-21C516 |
TC-21C-513 Comfo |
| 496081 | 6 | |||||
| Optional Type H Sparkfoe |
HE | 491009 | 50 | |||
| 491010 | 6 | |||||
| OptiFilter GMA | OV | Approved for not more than 1000 ppm organic vapors. *1,2,3,4 |
800375 | 10 | TC-23C-1262 (Ultravue) |
TC-23C-1256 (Comfo) |
| OptiFilter GMA-H | OV / HE | Approved for not more than 1000 ppm organic vapors; (99.97% efficiency filter) for particulate aerosols*1,2,3,4,5 | 800376 | 6 | TC-23C-1263 (Ultravue) |
TC-23C-1257 (Comfo) |
| OptiFilter GMB | AG | Approved for chlorine, chlorine dioxide, hydrogen chloride, sulfur dioxide. *1,2,4 | 800372 | 10 | TC-23C-1315 (Ultravue) |
TC-23C-1312 (Comfo) |
| OtiFilter GMB-H | AG / HE | Approved for chlorine, chlorine dioxide, hydrogen chloride, sulfur dioxide; (99.97% efficiency filter) for particulate aerosols. *1,2,4,5 | 800373 | 6 | TC-23C-1316 (Ultravue) |
TC-23C-1313 (Comfo) |
| OptiFilter GMC | OV / AG | Approved for not more than 1000 ppm organic vapors; chlorine, chlorine dioxide, hydrogen chloride, sulfur dioxide and escape only from hydrogen sulfide. *1,2,3,4 |
494215 | 10 | TC-23C-1054 (Ultravue) |
TC-23C-1250 (Comfo) |
| OptiFilter GMC-H | OV/AG/HE | Approved for not more than 1000 ppm organic vapors; chlorine, chlorine dioxide, hydrogen chloride, sulfur dioxide and escape only from hydrogen sulfide. (99.97% efficiency filter) for particulate aerosols. *1,2,3,4,5 |
494217 | 6 | TC-23C-1056 (Ultravue) |
TC-23C-1252 (Comfo) |
| OptiFilter GMD | AM / MA | Approved for Ammonia and Methylamine. *1,2,4 | 494216 | 10 | TC-23C-1055 (Ultravue) |
TC-23C-1251 (Comfo) |
| OptiFilter GMD-H | AM/MA/HE | Approved for Ammonia and Methylamine. (99.97% efficiency filter) for particulate aerosols. *1,2,4,5 | 494219 | 6 | TC-23C-1058 (Ultravue) |
TC-23C-1254 (Comfo) |
| OptiFilter Mersorb-H | MV / HE | Approved for metallic mercury vapor and chloriine. (99.97% efficiency filter) for particulate aerosols. *1,2,4,5 | 803523 | 6 | TC-23C-1365 (Ultravue) |
TC-23C-1364 (Comfo) |
| *1: Cannot be used with Prefilter / Cover Assembly P/N 497098. | ||||||
| *2: Do not use in atmospheres containing less than 19.5% oxygen or in atmospheres immediately dangerous to life and health. | ||||||
| *3: Do not wear for protection against organic vapors with poor warning properties or those which generate high heats of reaction with the sorbent materials in the cartridge. | ||||||
| *4: Cannot be used on PAPRs with Tyvek Hood. | ||||||
| *5: 99.97 per cent efficient against 0.3 micron DOP. | ||||||
![]() |
|
The OptimAir 6HC PAPR is specifically designed to protect health care professionals from residual Chemical/Biological/Radiological agents when they are performing first responder duties during homeland security or terrorist situations. The system features a lightweight, chemical resistant Tychem SL hood and belt mounted blower with two HC cartridges. The canisters contain a pleated high efficiency (P100) filter to remove aerosols, radionuclides and solid particulates, and an impregnated activated carbon bed to adsorb gases and vapors. The carbon bed is the same as used in military canisters and is effective against Mustard (HD), Sarin (GB), DMMP (a Sarin simulant), HCN and CK.
|
|
| OptimAir 6HC PAPR with Tychem SL Hood | |
| OptimAir 6HC PAPR with Tychem SL hood includes motor/blower module, lithium battery, hood, breathing tube, belt and 2 HC cartridges | 10041550 |
| HC cartridges, package of 6 | 10042448 |
| Tychem SL hood | 10048179 |
| Breathing tube for hood | 481980 |
| Single use lithium battery | 10048180 |
| Ni-Cad battery for training use | 491120 |
| Single unit, single rate battery charger for Ni-Cad battery | 463471 |
| Motor/blower module | 10048178 |
| Polyurethane coated nylon belt | 492827 |
| Other OptimAir 6A and/or 6HC Replacement Parts & Accessories | |
| Breathing Tube Assemblies | |
| For tight fitting facepieces, 30" | 486364 |
| 36" breathing tube for tight fitting facepieces | 492197 |
| For Tyvek hood | 481980 |
| Protective Cover | |
| Protects PAPR from water (such as in asbestos decontamination shower) or particulate contamination. Pkg. of 5 for OptimAir 6A | 808494 |
| Flow Check Devices | |
| MSA flow check devices allow users of PAPRs to quickly and conveniently verify that their unit is providing the required air flow | |
| Flow check meter | 487995 |
| Adabper for flow check meter for use with Tyvek hood | 489999 |
| Adapter for flow check meter for use with OptimAir MM PAPR | 491046 |
![]() |
| The OptimAir MM 2K PAPR is designed for abatement, nuclear, lead and other hazardous particulate environments. The PAPR filters particulates from ambient air and provides a constant flow of respirable air to the Advantage 3000 Ultravue or Ultra Elite facepiece. The mask mounted motor/blower with HEPA filter has a low profile design that enhances user maneuverability and simplifies decontamination. The PAPR includes a small, lightweight, water resistant nickle metal hydride (NiMH) battery pack that will operate for 8 hours of continuous use. Weighing only 12.5 oz., it measures only 3" X 5" X 1". The low profile unit fits close to the wearer's body. The sealed battery pack is water resistant for easy shower decontamination. The NiMH battery does not have the "memory effect" associated with Ni-Cad batteries. The standard dual-rate battery charger will recharge a fully discharged battery in less than 3 hours. |
| All assemblies include: motor/blower, NiMH battery, dual-rate charger, cable, one type HE OptiFilter XL cartridge, belt and choice of Advantage 3000, Ultravue or Ultra Elite facepiece. | |||
| Advantage 3000 PAPR | |||
| Small | Medium | Large | |
| With rubber harness | 100034152 | 10034150 | 10034151 |
| With Advantage harness | 10034155 | 10034153 | 10034154 |
| Ultravue PAPR | |||
| Black silicone | 10023881 | 10023859 | 10023880 |
| Black hycar (nitrile rubber) | 10023858 | 10023569 | 10023857 |
| Ultra Elite PAPR | |||
| Black silicone | 10023886 | 10023887 | 10023885 |
| Black hycar | 10023882 | 10023883 | 10023884 |
| Replacement Facepieces | |||
| Advantage 3100 Single-Port Respirator Facepiece | |||
| With rubber harness | 10028999 | 10028998 | 10029000 |
| With Advantage harness | 10031343 | 10031342 | 10031344 |
| Ultravue PAPR | |||
| Black silicone | 480251 | 480247 | 480255 |
| Black hycar | 471218 | 457126 | 471230 |
| Ultra Elite PAPR | |||
| Black silicone | 493072 | 493028 | 493116 |
| Black hycar | 493064 | 493020 | 493108 |
| OptiFilter Cartridges for OptimAir MM 2K PAPR | |||
| MSA Purifying Element | Protection Code | No. in Box | Part No. |
| OptiFilter XL, Type HE | HE | 20 | 10042346 |
| OptiFilter XL, Type HE | HE | 6 | 496081 |
| Type HE OptiFilter XL Prefilter/Cover for use with OptimAir MM 2K PAPR. Designed to reduce filter loading in asbestos abatement and other high dust applications |
|
| OptiFilter XL prefilter cover | 497098 |
| Prefilters, box of 50 | 493524 |
| Flow check meter | 487995 |
| Adapter for flow check meter for use with OptimAir MM PAPR | 491046 |
| OptimAir MM 2K PAPR Upgrade Kit | |
| Upgrade kit includes: motor/blower module, NiMH battery, dual-rate charger, cable, one Type HE OptiFilter cartridge, and belt. Use your present demand style Ultravue or Ultra Elite facepiece or order facepiece separately | |
| OptimAir MM 2K PAPR Upgrade Kit | 10025945 |
| Replacement Parts | |
| NiMH battery pack for OptimAir MM 2K PAPR | 10023481 |
| Motor/blower assembly | 10023482 |
| Cable assembly | 10023480 |
| Dual-rate battery charger for OptimAir MM 2K | 10023483 |
![]() |
||
The OptimAir TL PAPR is designed for loose-fitting hoods to protect against particulates, toxic gases and vapors, or a combination. "Smart" features set flow rates automatically through built-in sensors. Unit offers audible and visual alarms for added worker safety. Audible alarms travel up the breathing tube close to the user's ear. Smart Design Features |
||
| OptimAir TL PAPR | ||
| OptimAir Kit with standard battery for hoods | 10081116 | |
| Tychem QC Hoods | ||
With suspension, 4-pack |
Single bib | Double bib |
| Threaded connector | 10083329 | 10083330 |
| Standard | 10083383 | 10083384 |
| With suspension, 4-pack, yellow | Single bib | Double bib |
| Threaded connector | 10086925 | 10086926 |
| Tychem SL Hoods | ||
| With suspension, 4-pack | Single bib | Double bib |
| Threaded connector | 10083381 | 10083382 |
| Standard | 10083385 | 10083386 |
| Hood Accessories | ||
| Hose clamp for standard hood, 6-pack | 10083843 | |
| Hood hose | 10049631 | |
| Suspension only, for Tyvek hood | 10078469 | |
| Sweatband for hood suspension, 10-pack | 10083618 | |
| "O" Ring replacement, hose hood, 10-pack | 10085084 |
|
| OptimAir TL PAPR Accessories | ||
| Cartridges | ||
| HE cartridge, 6-pack, Hi-efficiency particulate | 10080455 | |
| GMC HE cartridge, 6-pack, (organic vapors, acid gases, HE) | 10080454 | |
| GME HE cartridge, 6-pack, (acid gases, ammonia, formaldehyde, HE) | 10080456 | |
| Cartridge receptacle cover | 10081414 | |
| Battery and Charger | ||
| Standard battery for OptimAir TL PAPR | 10076108 | |
| Standard battery charger for OptimAir TL PAPR | 10076110 | |
| Long-life battery for OptimAir TL PAPR | 10076109 | |
| Long-life battery charger for OptimAir TL PAPR | 10076107 | |
| Decon Accessories | ||
| Decon cover for OptimAir TL PAPR, 5-pack, clear | 10075799 | |
| Decon cover for OptimAir TL PAPR, 5-pack, yellow | 10087152 | |
| Decon belt (backpack buckle) | 10078201 | |
| Decon belt (cam lock buckle) | 10074725 | |
| WARNING! | |||
| An appropriate cartridge change-out schedule must be developed by a qualified professional unless the cartridge / canister utilizes an end-of-service-life indicator. The change-out schedule must take into account all factors that may influence respiratory protection including specific work practices and other conditions unique to the worker's environment. If using against substances having poor warning properties, there is no secondary means of knowing when to replace the cartridges/canister. In such cases, take appropriate additional precautions to prevent overexposure, which may include a more conservative change-out schedule or using an air-supplied respirator or SCBA. Failure to follow this warning can result in serious personal injury or death. As a reference, below is a partial list of substances having poor warning properties. | |||
| Acrolein | Hydrogen Cyanide | Nitric Acid | Phosphorous Trichloride |
| Aniline | Hydrogen Selenide | Nitro Compounds (below) | Stibine |
| Arsine | Methanol | Nitrogen Oxides | Sulfur Chloride |
| Bromine | Methyl Bromide | Nitroglycerin | Urethane or other Diisocyanate containing paints |
| Carbon Monoxide | Methyl Chloride | Nitromethane | Vinyl Chloride |
| Diisocyanates | Methylene Chloride | Phosgene | |
| Dimethyl Sulfate | Nickle Carbonyl | Phosphine | |
| WSP home | Products | Suppliers |
| MSA index page | Previous MSA page | Next MSA page |