MSA SAFESITE® Multi-Threat Detection System & HAZMATCAD

For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

Credit Card Images

SAFEMTX Multi-Threat Detector SAFECOM Command Center
SAFESITE multi-threat detection system; typical installation and components

The SAFESITE Multi-Threat Detection System monitors, detects and communicates the presence of up to six potential threats, including chemical warfare agents (CWAs), gamma radiation, volatile organic compounds (VOCs), toxic industrial chemicals (TICs), combustible gases and oxygen deficiency - all within a wireless network.
The SAFESITE System combines state-of-the-art detection technology with advanced wireless communications capabilities to provide superior preventative and counter-measure solutions for:

• Homeland Security
• Emergency Response
• Public Events
• Building Protection
• Mass Transportation Centers
• Perimeter Monitoring
• Hazardous Response
• Port Surveillance
• Confined Space Monitoring

The SAFESITE System consists of two main components, the SAFEMTX™ Multi-Threat Detector and the SAFECOM™ Command Center. The system can be installed permanently (wired or wireless) for continual monitoring or deployed as a portable system.
The SAFEMTX Multi-Threat Detector utilizes multi-sensing technologies to detect up to six potential threats; helping first responders, law enforcement and government agents reduce the risk of exposure and facilitate consequence management.

Threat Technology Benefit
Chemical warfare agents Surface acoustic wave (SAW) Low false positive and false alarms, differentiates nerve and blister agents
Gamma radiation Cadmium zinc telluride (CZT) Sensitive with adjustable threshold and 2 ranges. (0 - 100 mR/hr, 0.1 mR/hr resolution & 0 - 1000 mR/hr, 1 mR/hr resolution)
Volatile organic compounds Photo-ionization detector (PID) 10.6 eV lamp provides ppm readings for broadband toxics and VOC detection
Toxic industrial chemicals Electro-chemical Detects many specific toxic gases such as chlorine, ammonia, hydrogen cyanide and hydrogen chloride
Oxygen deficiency/enrichment Electro-chemical Oxygen monitoring for confined space
Combustible gas Catalytic bead Wide range detection for hydrocarbons

The SAFECOM Command Center receives mission-critical information from the SAFEMTX Detectors and permits this crucial and wide-ranging data to be quickly converted to practical information for rapid decision-making through an uncomplicated graphical user interface. The SAFECOM Command Center can manage up to two systems with 16 SAFEMTX Detectors per system, integrating SAFEMTX data, including:
• Gas readings
• Relative CWA Threat Level
• Radiation dose rate
• Alarm status
• GPS location
• Battery run time
• RF signal strength
• Fault conditions
• SAFEMTX min, max, and average values
Through the SAFECOM Command Center, alarms are identified with both visual and audible alarms; alarms can then be acknowledged and silenced, detectors can be enabled and disabled, event logs and event log history can be viewed, plus units can be customized to suit specific deployment scenarios.
The SAFECOM Command Center maps SAFEMTX Detectors through GPS technology, specific address input or “click and dragging” icons onto images. The SAFECOM Command Center is also a TCP/IP hub, allowing all information to be placed on a network for remote viewing.
Wireless Technology:
The SAFESITE System provides two miles of wireless communication between any SAFEMTX Detector and SAFECOM Command Center and when necessary, the SAFECOM Command Center can configure any SAFEMTX Detector as a repeater to ensure maximum signal strength and reliable deployment without the need to move units.
SAFEPAC™ Perimeter Area Command Kit
SAFESITE SAFEPAC Perimeter Area Command Kit provides a basic kit for quick deployment and monitoring of an event or a location. The kit includes two Pelican Cases with an internal battery charger, 4 SAFEMTX Multi-Threat Detectors, 1 SAFECOM Command Center, all necessary PC Interface software plus 4 extra batteries. A laptop PC is also available as an option or you can use an existing PC.
1: Case – weather-resistant case provides for safe storage of system components
2: Internal battery charger – allows charging of system batteries while in storage. Charges 4 back-up lithium-ion batteries
3: SAFEMTX Detectors – stores up to 4 customer specified units and powers them through AC connection
4: SAFECOM Command Center – storage for SAFECOM Command Center plus laptop PC
5: Calibration kit – storage for calibration kits in SAFECOM box (kit is optional)
6: Storage compartments – storage for all power cords, adapters, manuals, calibration cylinders and other relevant equipment

SAFEMTX Multi-Threat Detector Specifications
Operating Temperature -20° to +50°C (-4° to +122°F)
Operating Humidity 0-95% RH, non-condensing
Dimensions 12"W x 12.5"H x 7.75"D
Weight 11 lbs.
Power 110 VAC or 12 VDC
Radio 900 mHz, 1W, spread spectrum, frequency-hopping
Battery Type Lithium-ion or alkaline
Battery Run-Time
Lithium-ion with SAW 7 hours
Lithium-ion without SAW 24 hours
Gamma Radiation Detector Specifications & Sensitivity
CZT 0-100 mRem/hr. / 0.1 mRem/hr. resolution
CZT 0-1000 mRem/hr. / 1.0 mRem/hr. resolution
CWA Sensor Specifications
Technology Surface Acoustic Wave Microsensor
Sensor Analysis Time 30 seconds
Warm-up Time <5 minutes
Alarm Thresholds
Nerve Agents 0.5 mg/m3
Blister Agents 2.0 mg/m3
Operating Temperature 0° to +40°C (32° to +104°F)
VOC, Toxic and Oxygen Sensor Specifications
Drift
Zero Drift <5%/Yr., typically
Span Drift <10%/Yr., typically
Noise <1% full scale
Accuracy
Repeatability ±1% FS or 2 ppm (VOC)
Linearity ±2% FS (combustible; O2; CO)
±10% FS or 2 ppm (others)
Step Change Response T50 O2 and toxics <30 sec. (typical)
T50 Combustibles & VOCs <15 sec. (typical)
Approvals
Hazardous Location Class I, Division 2, Groups A, B, C, D
Ingress Protection IP 65; totally protected against dust and protected against low pressure jets of water from all directions
SAFECOM Command Center Specifications
Power 110 VAC or 12 VDC
Weight 7 lbs
Dimensions 12"W x 12.5"H x 7.75"D
Radio 900 MHz, 1W, spread spectrum, frequency-hopping
Connectivity TCP/IP hub
Note: This Data Sheet contains only a general description of the product shown. While uses and performance capabilities are described, under no circumstances should the product be used except by qualified, trained personnel, and not until the instructions, labels or other literature accompanying the product have been carefully read and understood and the precautions therein set forth followed. Only they contain the complete and detailed information concerning this product.

Specific Sensors Available for SAFEMTX
Sensor Type Range & Full Scale (Sensors separated by slashes - /)
Ammonia 0-100 PPM / 0-1000 PPM
Arsine 0-2 PPM
Bromine 0-5 PPM
Carbon monoxide 0-100 PPM / 0-500 PPM / 0-1000 PPM
CWA See Specs above
Chlorine 0-5 PPM / 0-10 PPM / 0-20 PPM
Chlorine dioxide 0-3 PPM
Combustible gases 0-100% LEL
Diborane 0-50 PPM
Ethylene oxide 0-10 PPM
Fluorine 0-5 PPM
Gamma radiation See Specs above
Germane 0-3 PPM
Hydrogen fluoride 0-10 PPM
Hydrogen 0-1000 PPM
Hydrogen chloride 0-50 PPM
Hydrogen cyanide 0-50 PPM
Hydrogen sulfide 0-10 PPM / 0-50 PPM / 0-100 PPM / 0-500 PPM
Nitric oxide 0-100 PPM
Nitrogen dioxide 0-10 PPM
Oxygen 0-10% / 0-25%
Phosphine 0-2 PPM
Silane 0-25 PPM
Sulfur dioxide 0-25 PPM / 0-100 PPM
VOC PID 0-200 PPM / 0-1500 PPM

SafeConnect Belt-Bridge
The SAFECONNECT™ Belt-Bridge works with the Sirius Detector for integration into the MSA SAFESITE® Multi-Threat Detection System. These new system components offer up to two miles of wireless communication plus an updated Graphical User Interface (GUI) which provides all mission-critical information in one uncomplicated format.
SAFECONNECT Belt-Bridge
  • Interfaces wirelessly to existing Sirius Multigas PID Detector
  • Provides GPS location tracking in real time
  • Utilizes the same 1-watt, 900 MHz, spread spectrum, frequency hopping radio of the SAFEMTX™ detector and enables up to two miles communication between the SAFECONNECT wireless belt-bridge and the SAFESITE command center
  • Includes a 15-minute quick charger that rapidly restores the AA NiMH rechargeable batteries
Specifications: SAFECONNECT™ Belt-Bridge
Size 6.5"x4.5"x2.5"
Weight 1.2 lbs
Ingress Protection Rating IP54
Temperature -20 to +50C (-4 to +122F)
Humidity Operating humidity range 0-95% RH, non-condensing
Wireless Interface 902 - 928 MHz, 1 watt, spread spectrum, frequency-hopping radio
Communication Range 2 miles line-of-site back to command station
GPS Location Standard
Battery Type 4 AA NiMH rechargeable or alkaline batteries
Battery Charge Time 15 minutes
Battery Runtime 12 hours nominal
Warranty One year parts and labor standard
Specifications: Sirius® Wireless Interface
Size 3.5"x2.1"x1.0"
Weight 0.15 lbs
Ingress Protection Rating IP54
Temperature -20 to +50C (-4 to +122F)
Humidity Operating humidity range 0-95% RH, non-condensing
Wireless interface Bluetooth technology
Communication Range 6 feet to SAFECONNECT Belt-Bridge
Battery Type CR2477 1000mAH replaceable coin cell
Battery Runtime 18 months (50 hours per week operation)
Warranty One year parts and labor standard
Ordering Information
Part Number Description
10071439 SAFECONNECT Belt-Bridge Assembly
10073837 Sirius Wireless Kit, includes extended boot and wireless module
10073312 SAFECONFIG Installation Software

SAFECONFIG Software
SAFECONFIG Software
  • Configures SAFEMTX™ Detectors or SAFECONNECT Belt-Bridges as repeaters, ensuring maximum signal strength
  • Modifies system assignment of SAFEMTX Detectors
  • Greatly expands detection distance of SAFESITE System
  • Allows the setup of two repeaters per SAFESITE Sysem
  • Enables detection units to move from one system to another
  • Runs independently of the SAFESITE System


HAZMATCAD Chemical Agent Detectors
HAZMATCAD

HAZMATCAD™ and HAZMATCAD Plus Hazardous Material Chemical Agent Detectors
HAZMATCAD Detector
The HAZMATCAD Hazardous Material Chemical Agent Detector is a handheld instrument that detects and classifies Chemical Warfare Agents (CWA). When compared to other technologies, the HAZMATCAD Detector offers more capabilities and greater reliability at a lower cost.
Features

  • Compact, light-weight and portable
  • Self-diagnostic check during rapid warm-up
  • Alphanumeric display with LED alarms
  • Dual-Mode SAW Operation-Fast or High Sensitivity
  • Operates between 8 and 12 hours on rechargeable Li-Ion batteries
  • Vapor-diffusion check source verifies system performance
  • Unit can be hand-carried or worn on belt
  • RS-232 and IrDA communication ports; stores up to 8 hours of data
  • Inlet design protects against dust and particulates

HAZMATCAD Plus Detector
The HAZMATCAD Plus Detector detects for Chemical Warfare Agents ICWAj and selected Toxic Industrial Chemicals (TICs). It is a portable instrument designed for one-hand operation. It is very easy to operate and requires limited training for effective use.
Features

  • Self-diagnostic check during rapid warm-up
  • Alphanumeric display with LED alarms
  • Dual-Mode SAW Operation - Fast or High Sensitivity
  • Electrochemical Cells - Real time analysis
  • Operates between 8 and 12 hours on rechargeable Li-Ion batteries
  • Vapor-diffusion check source verifies system performance
  • RS-232 and IrDA communication ports; stores up to 8 hours of data
  • Inlet design protects against dust and particulates
Kits include: HAZMATCAD Detector; battery charger; belt clip; two Sony rechargeable batteries; hard, water-resistant carrying case; operating manual; vapor check source
Part No. Instrument Chemical Agents Detected
10055094 HAZMATCAD Detector Nerve and Blister
10055095 HAZMATCAD Detector Nerve, Blister and Hydrogen Cyanide
10055096 HAZMATCAD Detector Nerve, Blister and Phosgene
10055097 HAZMATCAD Plus Detector Nerve and Blister agents and TICs (phosgene, hydrogen cyanide, halogen and hydride gas)

HazMat Response Kit
HazMat Response Kit

HazMat Response Kit
The HazMat Response Detector Tube Kit can be used by firefighters, HazMat Response Teams and other workers to help classify unknown chemical gases and vapors at accident or spill sites. A Quad-Port Sampler allows four chemical classes to be tested simultaneously. The portable kit contains 12 types of De­tector Tubes (each with sufficient tubes for 10 complete tests!, a Kwik-Draw Pump to draw the sample through the tubes, the multiple tube holder and a convenient, easy-to-follow interpretation guide.
Features & Benefits

  • Quickly classifies unknown chemical gases and vapors
  • Quad-Port Sampler allows simultaneous testing with four detector tubes, meaning less time in IDLH atmosphere
  • Flow-limiting orifices ensure even sample flow
  • Portable and easy to handle
  • Includes simple interpretation guide
807472 Includes 12 types of detector tubes, multiple tube holder, Kwik-Draw pump and interpretation guide
485233 Extra Quad-Port Sampler


BIOSENSOR 2200R Biological Agent Detector
BIOSENSOR 2200R Biological Agent Detector  BIOSENSOR 2200R in use

BIOSENSOR™ 2200R Biological Agent Detector
The new BIOSENSOR 2200R Biological Agent Detector from MSA is a handheld, portable, on-site instrument for rapid detection, analysis, and identification of biological agents. Unique bioassay technology offers excellent sensitivity and low false positives while offering ease of use during white powder response calls. This highly accurate detection method provides rapid measurement of biohazards such as anthrax, ricin, botulism, SEB, and plague.
Exclusive five minute time-to-answer allows first responders to make informed critical decisions more rapidly than any other biological agent detector. The BIOSENSOR 2200R employs dynamic surface generation, a patent pending type of immunoassay detection technology. This technology offers significant advantages over other field-based assay methods by combining the benefits of both the free solution and lateral flow types. The result is more rapid analysis, a user-friendly format, and detector stability within a wide range of climates.
Both wet and dry samples may be tested and results are displayed with a simple red (target presentl or green (no target presentl indication. As tests are nondestructive, samples may
be retained as evidence. Single-test, disposable cartridges with on-board reagents have a 12-month shelf life. This instrument is permanently housed in a sturdy, lightweight Pelican case.
Instrument Features and Benefits

  • 5 minute time-to-answer
  • Uses positive and negative control cartridges
  • Battery-operated with ability to run 50 tests on a single charge
  • Fully deconable housing; IP67 rated
  • Visual and audible alarms provide clear indication of status
  • Extremely easy to use with a training time of one hour
  • Integrated RFID (radio frequency identificationl for automatic cartridge recognition

Targets

  • Anthrax/ricin duplex-one test, two agents
  • Anthrax
  • Ricin
  • SEB (staphylococcal enterotoxin B)
  • Botulism*
  • Plague*
  • Smallpox*
  • Tularemia*
  • Cholera*
  • West Nile virus*
    * Additional agent in development
10084834 MSA BIOSENSOR 2200R Biological Agent Detector Kit*, includes carry case, charger, cartridge starter kit (10084758), instruction manual, and quick start guide
BIOSENSOR Cartridge Plans
10084758

MSA BIOSENSOR cartridge starter kit includes 3 Anthrax/Ricin dual kits**,
1 Anthrax, 1 Ricin, 3 positive control, 2 negative control cartridges, and 2 wet sample kits

10084753 MSA BIOSENSOR Low volume cartridge plan includes 6 Anthrax/Ricin dual kits**,
2 Anthrax, 2 Ricin, 6 positive control, 2 negative control cartridges, and 2 wet sample kits
10084754 MSA BIOSENSOR Medium volume cartridge plan includes 24 Anthrax/Ricin dual kits**,
6 Anthrax, 6 Ricin, 24 positive control. 6 negative control cartridges, and 4 wet sample kits
10084755 MSA BIOSENSOR High volume cartridge plan includes 60 Anthrax/Ricin dual kits**,
8 Anthrax, 8 Ricin, 60 positive control. 8 negative control cartridges, and 6 wet sample kits .
* Extended warranties available
** Each biohazard cartridge test kit includes a dry sample kit.

WSP home Products Suppliers