For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.
![]() |
![]() |
| SAFEMTX Multi-Threat Detector | SAFECOM Command Center |
![]() |
|
| SAFESITE multi-threat detection system; typical installation and components | |
| The SAFESITE Multi-Threat Detection System monitors, detects and communicates the presence of up to six potential threats, including chemical warfare agents (CWAs), gamma radiation, volatile organic compounds (VOCs), toxic industrial chemicals (TICs), combustible gases and oxygen deficiency - all within a wireless network. The SAFESITE System combines state-of-the-art detection technology with advanced wireless communications capabilities to provide superior preventative and counter-measure solutions for: • Homeland Security The SAFESITE System consists of two main components, the SAFEMTX Multi-Threat Detector and the SAFECOM Command Center. The system can be installed permanently (wired or wireless) for continual monitoring or deployed as a portable system. |
||
| Threat | Technology | Benefit |
| Chemical warfare agents | Surface acoustic wave (SAW) | Low false positive and false alarms, differentiates nerve and blister agents |
| Gamma radiation | Cadmium zinc telluride (CZT) | Sensitive with adjustable threshold and 2 ranges. (0 - 100 mR/hr, 0.1 mR/hr resolution & 0 - 1000 mR/hr, 1 mR/hr resolution) |
| Volatile organic compounds | Photo-ionization detector (PID) | 10.6 eV lamp provides ppm readings for broadband toxics and VOC detection |
| Toxic industrial chemicals | Electro-chemical | Detects many specific toxic gases such as chlorine, ammonia, hydrogen cyanide and hydrogen chloride |
| Oxygen deficiency/enrichment | Electro-chemical | Oxygen monitoring for confined space |
| Combustible gas | Catalytic bead | Wide range detection for hydrocarbons |
| The SAFECOM Command Center receives mission-critical information from the SAFEMTX Detectors and permits this crucial and wide-ranging data to be quickly converted to practical information for rapid decision-making through an uncomplicated graphical user interface. The SAFECOM Command Center can manage up to two systems with 16 SAFEMTX Detectors per system, integrating SAFEMTX data, including: • Gas readings • Relative CWA Threat Level • Radiation dose rate • Alarm status • GPS location • Battery run time • RF signal strength • Fault conditions • SAFEMTX min, max, and average values Through the SAFECOM Command Center, alarms are identified with both visual and audible alarms; alarms can then be acknowledged and silenced, detectors can be enabled and disabled, event logs and event log history can be viewed, plus units can be customized to suit specific deployment scenarios. The SAFECOM Command Center maps SAFEMTX Detectors through GPS technology, specific address input or “click and dragging” icons onto images. The SAFECOM Command Center is also a TCP/IP hub, allowing all information to be placed on a network for remote viewing. Wireless Technology: The SAFESITE System provides two miles of wireless communication between any SAFEMTX Detector and SAFECOM Command Center and when necessary, the SAFECOM Command Center can configure any SAFEMTX Detector as a repeater to ensure maximum signal strength and reliable deployment without the need to move units. |
|
| SAFEPAC Perimeter Area Command Kit SAFESITE SAFEPAC Perimeter Area Command Kit provides a basic kit for quick deployment and monitoring of an event or a location. The kit includes two Pelican Cases with an internal battery charger, 4 SAFEMTX Multi-Threat Detectors, 1 SAFECOM Command Center, all necessary PC Interface software plus 4 extra batteries. A laptop PC is also available as an option or you can use an existing PC. 1: Case weather-resistant case provides for safe storage of system components 2: Internal battery charger allows charging of system batteries while in storage. Charges 4 back-up lithium-ion batteries 3: SAFEMTX Detectors stores up to 4 customer specified units and powers them through AC connection 4: SAFECOM Command Center storage for SAFECOM Command Center plus laptop PC 5: Calibration kit storage for calibration kits in SAFECOM box (kit is optional) 6: Storage compartments storage for all power cords, adapters, manuals, calibration cylinders and other relevant equipment |
|
![]() |
![]() |
![]() |
|
| Operating Temperature | -20° to +50°C (-4° to +122°F) |
| Operating Humidity | 0-95% RH, non-condensing |
| Dimensions | 12"W x 12.5"H x 7.75"D |
| Weight | 11 lbs. |
| Power | 110 VAC or 12 VDC |
| Radio | 900 mHz, 1W, spread spectrum, frequency-hopping |
| Battery Type | Lithium-ion or alkaline |
| Battery Run-Time | |
| Lithium-ion with SAW | 7 hours |
| Lithium-ion without SAW | 24 hours |
| Gamma Radiation Detector Specifications & Sensitivity | |
| CZT | 0-100 mRem/hr. / 0.1 mRem/hr. resolution |
| CZT | 0-1000 mRem/hr. / 1.0 mRem/hr. resolution |
| CWA Sensor Specifications | |
| Technology | Surface Acoustic Wave Microsensor |
| Sensor Analysis Time | 30 seconds |
| Warm-up Time | <5 minutes |
| Alarm Thresholds | |
| Nerve Agents | 0.5 mg/m3 |
| Blister Agents | 2.0 mg/m3 |
| Operating Temperature | 0° to +40°C (32° to +104°F) |
| VOC, Toxic and Oxygen Sensor Specifications | |
| Drift | |
| Zero Drift | <5%/Yr., typically |
| Span Drift | <10%/Yr., typically |
| Noise | <1% full scale |
| Accuracy | |
| Repeatability | ±1% FS or 2 ppm (VOC) |
| Linearity | ±2% FS (combustible; O2; CO) ±10% FS or 2 ppm (others) |
| Step Change Response | T50 O2 and toxics <30 sec. (typical) T50 Combustibles & VOCs <15 sec. (typical) |
| Approvals | |
| Hazardous Location | Class I, Division 2, Groups A, B, C, D |
| Ingress Protection | IP 65; totally protected against dust and protected against low pressure jets of water from all directions |
| SAFECOM Command Center Specifications | |
| Power | 110 VAC or 12 VDC |
| Weight | 7 lbs |
| Dimensions | 12"W x 12.5"H x 7.75"D |
| Radio | 900 MHz, 1W, spread spectrum, frequency-hopping |
| Connectivity | TCP/IP hub |
| Note: This Data Sheet contains only a general description of the product shown. While uses and performance capabilities are described, under no circumstances should the product be used except by qualified, trained personnel, and not until the instructions, labels or other literature accompanying the product have been carefully read and understood and the precautions therein set forth followed. Only they contain the complete and detailed information concerning this product. | |
| Sensor Type | Range & Full Scale (Sensors separated by slashes - /) |
| Ammonia | 0-100 PPM / 0-1000 PPM |
| Arsine | 0-2 PPM |
| Bromine | 0-5 PPM |
| Carbon monoxide | 0-100 PPM / 0-500 PPM / 0-1000 PPM |
| CWA | See Specs above |
| Chlorine | 0-5 PPM / 0-10 PPM / 0-20 PPM |
| Chlorine dioxide | 0-3 PPM |
| Combustible gases | 0-100% LEL |
| Diborane | 0-50 PPM |
| Ethylene oxide | 0-10 PPM |
| Fluorine | 0-5 PPM |
| Gamma radiation | See Specs above |
| Germane | 0-3 PPM |
| Hydrogen fluoride | 0-10 PPM |
| Hydrogen | 0-1000 PPM |
| Hydrogen chloride | 0-50 PPM |
| Hydrogen cyanide | 0-50 PPM |
| Hydrogen sulfide | 0-10 PPM / 0-50 PPM / 0-100 PPM / 0-500 PPM |
| Nitric oxide | 0-100 PPM |
| Nitrogen dioxide | 0-10 PPM |
| Oxygen | 0-10% / 0-25% |
| Phosphine | 0-2 PPM |
| Silane | 0-25 PPM |
| Sulfur dioxide | 0-25 PPM / 0-100 PPM |
| VOC PID | 0-200 PPM / 0-1500 PPM |
![]() |
![]() |
| The SAFECONNECT Belt-Bridge works with the Sirius Detector for integration into the MSA SAFESITE® Multi-Threat Detection System. These new system components offer up to two miles of wireless communication plus an updated Graphical User Interface (GUI) which provides all mission-critical information in one uncomplicated format. SAFECONNECT Belt-Bridge
|
|
| Specifications: SAFECONNECT Belt-Bridge | |
| Size | 6.5"x4.5"x2.5" |
| Weight | 1.2 lbs |
| Ingress Protection Rating | IP54 |
| Temperature | -20 to +50C (-4 to +122F) |
| Humidity | Operating humidity range 0-95% RH, non-condensing |
| Wireless Interface | 902 - 928 MHz, 1 watt, spread spectrum, frequency-hopping radio |
| Communication Range | 2 miles line-of-site back to command station |
| GPS Location | Standard |
| Battery Type | 4 AA NiMH rechargeable or alkaline batteries |
| Battery Charge Time | 15 minutes |
| Battery Runtime | 12 hours nominal |
| Warranty | One year parts and labor standard |
| Specifications: Sirius® Wireless Interface | |
| Size | 3.5"x2.1"x1.0" |
| Weight | 0.15 lbs |
| Ingress Protection Rating | IP54 |
| Temperature | -20 to +50C (-4 to +122F) |
| Humidity | Operating humidity range 0-95% RH, non-condensing |
| Wireless interface | Bluetooth technology |
| Communication Range | 6 feet to SAFECONNECT Belt-Bridge |
| Battery Type | CR2477 1000mAH replaceable coin cell |
| Battery Runtime | 18 months (50 hours per week operation) |
| Warranty | One year parts and labor standard |
| Ordering Information | |
| Part Number | Description |
| 10071439 | SAFECONNECT Belt-Bridge Assembly |
| 10073837 | Sirius Wireless Kit, includes extended boot and wireless module |
| 10073312 | SAFECONFIG Installation Software |
SAFECONFIG Software
|
![]() |
||
HAZMATCAD™ and HAZMATCAD Plus Hazardous Material Chemical Agent Detectors
HAZMATCAD Plus Detector
|
||
| Kits include: HAZMATCAD Detector; battery charger; belt clip; two Sony rechargeable batteries; hard, water-resistant carrying case; operating manual; vapor check source | ||
| Part No. | Instrument | Chemical Agents Detected |
| 10055094 | HAZMATCAD Detector | Nerve and Blister |
| 10055095 | HAZMATCAD Detector | Nerve, Blister and Hydrogen Cyanide |
| 10055096 | HAZMATCAD Detector | Nerve, Blister and Phosgene |
| 10055097 | HAZMATCAD Plus Detector | Nerve and Blister agents and TICs (phosgene, hydrogen cyanide, halogen and hydride gas) |
![]() |
|
HazMat Response Kit
|
|
| 807472 | Includes 12 types of detector tubes, multiple tube holder, Kwik-Draw pump and interpretation guide |
| 485233 | Extra Quad-Port Sampler |
![]() |
|
BIOSENSOR™ 2200R Biological Agent Detector
Targets
|
|
| 10084834 | MSA BIOSENSOR 2200R Biological Agent Detector Kit*, includes carry case, charger, cartridge starter kit (10084758), instruction manual, and quick start guide |
| BIOSENSOR Cartridge Plans | |
| 10084758 | MSA BIOSENSOR cartridge starter kit includes 3 Anthrax/Ricin dual kits**, |
| 10084753 | MSA BIOSENSOR Low volume cartridge plan includes 6 Anthrax/Ricin dual kits**, 2 Anthrax, 2 Ricin, 6 positive control, 2 negative control cartridges, and 2 wet sample kits |
| 10084754 | MSA BIOSENSOR Medium volume cartridge plan includes 24 Anthrax/Ricin dual kits**, 6 Anthrax, 6 Ricin, 24 positive control. 6 negative control cartridges, and 4 wet sample kits |
| 10084755 | MSA BIOSENSOR High volume cartridge plan includes 60 Anthrax/Ricin dual kits**, 8 Anthrax, 8 Ricin, 60 positive control. 8 negative control cartridges, and 6 wet sample kits . |
| * Extended warranties available ** Each biohazard cartridge test kit includes a dry sample kit. |
|
| WSP home | Products | Suppliers |
| MSA Index | Previous MSA Page |