MSA Advantage 200 & 1000 Respirators

For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

Credit Card Images

Advantage Respirators & Accessories
Advantage 200 Respirator Comfo Classic Cartridge adapter
for Advantage 200 Respirators
Advantage 1000 Respirator
The Advantage 200 Respirator is unlike any other half mask respirator. Offering unmatched fit and comfort, it is the first respirator to feature MSA's patented MultiFlix® System, a soft, pliable combination of rubber and plastic that provides a customized fit. The result is a respirator that feels great on any face because it works to remove the pressure points from the face seal area. At the same time, the MultiFlex® System delivers exceptional stability which means the Advantage 200 respirator won't collapse during wear.

The MultiFlex® System also includes the AnthroCurve™ Sealing Surface, which equalizes pressure on the face seal area, thereby eliminating unwelcome pressure points. This design results in an effective sealing surface that instantly conforms to the wearer's unique facial characteristics.

Advantage cartridges are compatible with 42 CFR 84 NIOSH approved Advantage 200 and Advantage 1000 Respirators.

Part No. 809999

Allows use of Comfo Cartridges on Advantage 200 and Advantage 1000 respirators.

The Advantage 1000 Full Face Respirator features a wraparound flexible lens that offers excellent fit and comfort with increased vision. It weighs 40% less than conventional full face respirators and uses the same cartridges as the Advantage 200 half mask respirator.

The Advantage 1000 respirator is constructed of super soft Hycar (nitrile rubber) that provides the feel and comfort of silicone but has better permeation resistance. The facepiece, which is available in three sizes, has a unique inturned lip seal that provides an exceptional seal against a wide range of facial contours. The Advantage 1000 facepiece also features a distinctive, flexible urethane lens that is integrally bonded to the facepiece, eliminating the need for rigid lens retainers that can cause unwanted pressure points.

Standard equipment includes a speaking diaphragm, for clear, short range communications, and a nose cup to reduce lens fogging in low temperature of high humidity conditions.

Advantage 200 Respirator Accessories
Description 2-Piece Neckstrap Single Neckstrap
Advantage 200 small 815696 815448
Advantage 200 medium 815692 815444
Advantage 200 large 815700 815452
Advantage 200 Respirators preassembled with cartridges and filters
Description Cartridge Part No.
Advantage 200 small OV-N95 816943
Advantage 200 medium OV-N95 816939
Advantage 200 large OV-N95 816947
Advantage 200 small Multigas R95 816701
Advantage 200 medium Multigas R95 816697
Advantage 200 large Multigas R95 816705
Advantage 1000 Respirators (Black, with speaking diaphragm and nosecup)
Small (Part No.) Medium (Part No.) Large (Part No.)
805414 805408 805420

 

Advantage 3000 Respirators
MSA Advantage 3000 Full Facepiece Respirator

The Advantage 3000 Full-Face Respirator incorporates MSA's global engineering expertise and is designed to meet NIOSH and EN standards.
The respirator features a wraparound lens combined with a soft, pliable silicone facepiece that provides a total solution to your air-purifying respirator needs.
Its fit technology is based on the proven faceseal of the Ultra Elite Facepiece, which was based on facial measurements from more than B,OOO people.
For the utmost in convenience, the Advantage 3000 uses the same cartridges and filters as the Advantage 200 LS Respirator.
The Advantage 3000 Respirator enhances worker performance through a new design that allows even lower breathing resistance and includes a standard nosecup that reduces fogging in low temperatures or high humidity conditions.
In addition, the facepiece lens has a scratch resistant coating and has been engineered to be optically correct, giving you superior visibility and peripheral vision. The Advantage 3000 Respirator meets all performance requirements of ANSI ZB7.1.2003 (protective eye and face protection).
Donning the mask is made easier with pre-adjustable rubber straps. With the Advantage 3000 Respirator, you can set the position of the upper straps to receive a consistent fit, time after time. In addition, the preset upper straps prevent uncomfortable snags during donning and doffing, and also provide a tighter, more secure seal. Wearers also can choose the new European-style Advantage harness, which dons like a catcher's mask.

Advantage 3000 Facepieces
Description Small Medium Large
Advantage 3200 Twin Port Respirator, w/rubber harness 10028996 10028995 10028997
Advantage 3200 Twin Port Respirator, w/Advantage European-style harness 10031340 10031309 10031341
Spectacle Kits for Full-Facepiece Respirators. For use by workers who must wear corrective lenses.
Spectacle Kit for Advantage 3000 10029298
Cover Lens for Advantage 3000. This clear, flexible cover lens protects the facepiece lens from scratches during storage, handling & use.
Cover Lens Clear, box of 25 10031542
Cover Lens Smoke, box of 25 10031543
Advantage Fit Test Adapter
Advantage Fit Test Adapter 10056424

Advantage 4000 Respirators
MSA Advantage 4000 Full Facepiece Respirator
The new Advantage 4000 Twin Port Full-Face Respirator raises the performance of industrial full-facepiece respirators to a new level. Based on the Advantage 3000 Facepiece, the respirator features a wraparound lens combined with a soft, pliable Hycar or silicone facepiece that provides a total solution to your air-purifying needs.
Its fit technology is based on the proven face seal of the Ultra Elite Facepiece. For the utmost in convenience, the Advantage 4000 uses the same cartridges and filters as the Advantage 200 LS and Advantage 3000 Respirator.
In addition, the facepiece lens has scratch-resistant coating and has been engineered to be optically correct, giving you superior visibility and peripheral vision. The Advantage 4200 Respirator also meets the performance requirements of ANSI ZB7.1.2003.
The Advantage 4000 Respirator enhances worker performance through a new design that allows low breathing resistance and includes a standard nosecup that reduces fogging in low temperatures or high humidity conditions.
Options include spectacle kits for corrective lenses, cover lens and welders adapter.
Donning the mask is made easier with a comfortable net-type harness with a four-point adjustable suspension. Wearers also can choose pre-adjustable rubber straps.
Advantage 4000 Facepieces
Description Small Medium Large
Advantage 4200 Twin Port Respirator, w/net head harness, Hycar 10083797 10083793 10083801
Advantage 4200 Twin Port Respirator, w/rubber head harness, Hycar 10083799 10083795 10083803
Advantage 4200 Twin Port Respirator, w/net head harness, Hycar 10083796 10083792 10083800
Advantage 4200 Twin Port Respirator, w/rubber head harness, Hycar 10083798 10083794 10083802
Spectacle Kits for Full-Facepiece Respirators. For use by workers who must wear corrective lenses.
Spectacle Kit for Advantage 4000 10029298
Cover Lens for Advantage 4000. This flexible cover lens protects the face piece lens during storage, handling and use.
Cover Lens Clear, box of 25 10031542
Cover Lens Smoke, box of 25 10031543
Welders Adapter
Clip-On Welders Adapter for Advantage 4000 Twin Port Facepiece, with cover lens, less filter plate 10065328

 

Flexi-Filter Pads for Advantage Respirators
These low-profile, flexible pads will fit well under a welding hood and with other personal protective equipment. The offer great balance and weight distribution for maintaining a good face seal, while their swept back design provides improved vision and comfort. In addition, their multi-layer composite construction gives them better durability and spark resistance. Finger tabs provide easy installation and prevent possible filter damage

Flexi-Filter pads are available in a wide range of filter classes and efficiencies. The P100 classification is for high efficiency protection against oil and non-oil containing hazards or hazard specific standards requiring HEPA filters such as OSHA's Lead and Asbestos standards.

Ordering Information
P100 818342
P100 OV, Ozone 818343
P100 AG, HF 818344
P100 HG, CL 818345
N95, pkg of 2 818346
N95, OV, pkg of 2 818347
N95 AG, HF 818348
N95 HG, CL 818349
P95, pkg of 2 818354
P95 OV pkg of 2 818355
P95 AG, HF 818356
P95 HG, CL 818357

Definitions for Chart below this table
OV = Organic Vapor CL = Chlorine SD = Sulfur Dioxide
CD = Chlorine Dioxide HC = Hydrogen Chloride HS = Hydrogen Sulfide
AM = Ammonia MA = Methylamine FM = Formaldehyde
HF = Hydrogen Fluoride MV = Mercury Vapor AG = Acid Gas
* = For Escape Only ** Effective against Iodine; Not NIOSH approved - = No (Not Applicable)

Cartridge
Designation
Part
No.
  Acid Gases           Filter Type & Efficiency  
OV CL SD CD HC HS AM MA FM HF MV P100 R95 N95 Notes
GMA (OV) 815355 Yes - - - - - - - - - - - Yes Yes 2,3
GMA (P100) 815362 Yes - - - - - - - - - - Yes - - 2,3,4
GMB (AG) 815356 - Yes Yes Yes Yes Yes - - - - - - Yes Yes 2
GMB (P100) 815363 - Yes Yes Yes Yes Yes - - - - - Yes - - 2,4
GMC (OV/AG) 815357 Yes Yes Yes Yes Yes Yes - - - - - - Yes Yes 2,3
GMC (P100) 815364 Yes Yes Yes Yes Yes Yes - - - - - Yes - - 2,3,4
GMD (AM/MA) 815358 - - - - - - Yes Yes - - - - Yes Yes 2,3
GMD (P100) 815365 - - - - - - Yes Yes - - - Yes - - 2,3,4
GME (multigas) 815359 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes - - Yes Yes 2,3
GME (P100) 815366 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes - Yes - - 2,3,4
GMI (P100) ** 815641 Yes - - - - - - - - - - Yes - - 2,4
Mersorb * 815361 - Yes - - - - - - - - Yes - Yes Yes 2,4
Mersorb (P100) 815368 - Yes - - - - - - - - Yes Yes - - 2,4
Low Profile P100 815369 - - - - - - - - - - - Yes - - 1,4
Stand alone
Flexi-Filter
818346 - - - - - - - - - - - - - Yes 1
Note 1 Do not use in atmospheres containing less than 19.5% oxygen, in atmospheres containing gases or vapors or in atmospheres immediately dagerous to life and health
Note 2 Do not use in atmospheres containing less than 19.5% oxygen, or in atmospheres immediately dagerous to life and health
Note 3 Do not wear for protection against organic vapors with poor warning properties or those which generate high heats of reaction with the sorbent material in the cartridge
Note 4 99.97% efficient against 0.3 micron DOP

WARNING!
An appropriate cartridge change-out schedule must be developed by a qualified professional unless the cartridge / canister utilizes an end-of-service-life indicator. The change-out schedule must take into account all factors that may influence respiratory protection including specific work practices and other conditions unique to the worker's environment. If using against substances having poor warning properties, there is no secondary means of knowing when to replace the cartridges/canister. In such cases, take appropriate additional precautions to prevent overexposure, which may include a more conservative change-out schedule or using an air-supplied respirator or SCBA. Failure to follow this warning can result in serious personal injury or death. As a reference, below is a partial list of substances having poor warning properties.
Acrolein Hydrogen Cyanide Nitric Acid Phosphorous Trichloride
Aniline Hydrogen Selenide Nitro Compounds (below) Stibine
Arsine Methanol Nitrogen Oxides Sulfur Chloride
Bromine Methyl Bromide Nitroglycerin Urethane or other Diisocyanate containing paints
Carbon Monoxide Methyl Chloride Nitromethane Vinyl Chloride
Diisocyanates Methylene Chloride Phosgene  
Dimethyl Sulfate Nickle Carbonyl Phosphine

WSP home Products Suppliers