For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.
We accept VISA and Mastercharge.
![]() Escort ELF Sampling Pump |
| The patented Escort ELF Sampling Pump can be used for personal and area sampling. The state-of-the-art electronic laminar flow sensor, consisting of a laminar flow element and pressure sensor, provides constant flow (volume) control with +/- 2.5% regulation of air flow rate (from 1 to 3 lpm) and automatic compensation for changes in battery voltage, temperature, altitude, and sample load.
An internal secondary standard calibrates the pump continously and needs to be checked against a primary standard only once a month (or every 200 hours for coal mine dust sampling). Approvals: |
| Escort ELF Pump with flow fault indicator, 110V single unit charger, Gemini® Twin Port Sampler, and standard packaging | 805559 |
| Escort ELF Pump with flow fault indicator, 110V single unit charger, sampling line, and standard packaging | 805560 |
| Replacement Parts | |
| Battery Pack with O-ring | 497702 |
| One replacement inlet water stop filter | 802897 |
| Escort Pump overhaul kit with common components for routine maintenance | 802922 |
| Inlet dust filter (package of 5) | 808935 |
![]() |
|
| The Escort LC Sampling Pump can be used with a variety of personal and area sampling devices to collect such airborne contaminants as asbestos fibers, toxic gases, vapors, particulates, fumes and mists. It can also be used to sample silica dust, coal dust, and organic vapors.
The Escort LC pump is exceptionally compact, lightweight and quiet in operation. Engineered for use in "hostile" enviroments, the unit can be sprayed with water while it is operating without being damaged. Approvals: |
|
| Escort LC Pump with 110V single unit charger, sampling line and standard packaging. | 711400 |
![]() MSA Jacket |
![]() MSA Sampling Equipment |
![]() MSA Omega Chargers |
| MSA Sampling Pump accessories and air sampling equipment allow monitoring of many different contaminants in various applications. Sampling pump accessories can be used in personal and area sampling for a wide variety of airborne contaminants such as asbestos fibers, toxic gases, vapors, particulates, mists and fumes.
Accessories for MSA sampling pumps include filter media, a cyclone assembly, preweighed filter cassettes, filter holder assemblies, impingers, the Gemini® Twin-Port Sampler, sorbent tubes and calibrators. |
||
| 811741 Leather Jacket for Sampling Pumps |
456226 Sampling Line Only |
494716 120 VAC 50/60 Hz |
| 456243 10 mm Cyclone Assembly to separate respirable dust from non-respirable dust |
495965 220 VAC 50/60 Hz |
|
| 497697 Gemini Twin-Port Sampler for sorbent tubes |
801759 120 / 240 VAC 50/60 Hz (five-unit charger) |
|
![]() |
|
| The NIOSH respirator certification standard 42 CFR Part 84, has introduced new ways to select non-powered air purifying particulate respirators. One of the primary concerns of the standard is oil-mist exposure. According to this NIOSH Standard, there are three levels of respiratory protection: N = Not resistant to oil; R = Resistant to oil; P = Oil proof. But how do you know whether oil mist is present in the workplace? MSA's 42 CFR Sampling Pump Kits can help you answer this question by providing convenience and flexiblility in oil-mist sampling. | |
Kit includes:
|
|
| Ordering Information | |
| Escort ELF 42 CFR Sampling Pump Kit | 711585 |
| Escort LC 42 CFR Sampling Pump Kit | 711586 |
![]() |
|
| The general purpose cassette is a sample cassette that can be used for silica sampliing. This cassette can also be used for all airborne particulate collection not limited to quartz or silica. This cassette is individually packaged in a sealed plastic bag. The cassette inlet contains a tamper proof deflector plate, and the outlet contains an anti-blow-back check valve. Both the inlet and outlet openings are capped to ensure cleanness. The perimeter of the cassette housing is sealed with tamper proof sealing tape. Because of the extreme accuracy of the MSA weighing process, users of this cassette can sample the atmosphere for dust particulates and have the analytical analysis performed with complete confidence in its accuracy. |
|
| General Purpose Cassette | 711361 |
![]() |
|
| The PAS-500 Micro Air Sampler Pump has the sampling tube, battery, pump and electronics all in one light (4 oz.), flame retardant case. Its flow range is 20 - 200 cc/minute. A low cost alkaline or zinc-carbon battery powers the unit for a 40 hour work week. Accepts many tube sizes and types. ETL Class I, Division 1 approved. | |
| Ordering Information | |
| PAS-500 Micro Air Sampler with holder for 6mm charcoal tube, two batteries | 697236 |
| Accessories | |
| Multi-Pump Carrying Case (holds 8) | 697237 |
| ATH-6 Holder for 6mm Charcoal Tubes | 697238 |
| ATH-8 Holder for 8mm Tubes, Perkin-Elmer Absorber Tubes | 697239 |
| ATH-10 Holder for Colorimetric or two 6mm Charcoal Tubes in Series for Methylene Chloride | 697240 |
| Low Flow Accessory for 20 to 55 cc/minute | 655646 |
![]() |
|
| Gemini® Twin-Port Sampler For low flow control when sorbent tubes are used, the patented Gemini Twin-Port Sampler is a valved mechanism that allows flow adjustment down to 1 mlpm (0.001 lpm to 500 mlpm total between both tubes). US Patent No. 5,370,004. As an added benefit, the Gemini accessory permits simultaneous sampling from sorbent tubes, with independently controlled flow rates of each. Dual sampling means two like sorbent tubes can be attached for simultaneous sampling at different flow rates, or two different tubes can be used to sample two types of substances at once. |
|
| Ordering Information | |
| Gemini Twin-Port Sampling Kit -- includes Gemini Sampler, tube protectors, Y-connector, clips and carrying case | 497697 |
| Charcoal Sampling Tubes (150 mg), 50 tubes | 697169 |
| Charcoal Sampling Tubes (600 mg), 50 tubes | 697170 |
| Silica Tubes (225 mg), 50 tubes | 697171 |
| Silica Tubes (600 mg), 50 tubes | 697172 |
| Amberlite XAD-2, 50 tubes | 697175 |
| Hopcalite, 50 tubes | 697176 |
| Carbotrap, 25 tubes | 697174 |
| Carbosieve, 25 tubes | 697173 |
| Tenax/CMS | 491165 |
![]() |
![]() |
| General Purpose Filter Cassettes Fifty complete 3-piece preloaded filter cassettes with MCE filters |
|
| With 25 mm, 0.8 micron pore size | 695677 |
| With 37 mm, 0.8 micron pore size | 695676 |
| MCE Filter Discs for Asbestos and Nuisance Dust | |
| 25 mm, 0.8 micron pore size, 100 / pack | 695674 |
| 37 mm, 0.8 micron pore size, 50 / pack | 463797 |
| 37 mm, 0.45 micron pore size, 50 / pack | 463796 |
| Silver Membrane Filters for Silica, Coke Oven Emmissions and Carbon Black | |
| Silver Membrane, 0.8 micron pore size, 50 / pack | 464324 |
| Filter Discs for Nuisance Dust Sampling Used with 37 mm cassettes |
|
| PVC, 0.5 micron pore size, 100 / pack | 459733 |
| PVC, 0.8 micron pore size, 50 / pack | 812805 |
| PVC, 5.0 micron pore size, 50 / pack | 625413 |
| Glass Fiber | 463784 |
![]() |
|
| All units include 50 complete filter cassettes preloaded with 25 mm MCE filters | |
| With 0.8 micron pore size and 50 mm anti-static cowl | 695679 |
| With 0.45 micron pore size and 5.0 micron pore size and 50 mm anti-static cowl | 696172 |
![]() |
|
| Preweighed filter cassette with 5 micron pore size PVC filter and Mine Data Card | 803462 |
| 10 mm Cyclone Assembly | 456243 |
![]() Couplers and Supplementary Parts Kit |
![]() Impinger assemblies & accessories |
![]() Gas Sampling Bags |
| MSA's complete line allows users to load sampling cassette cases and select your own combination of sampling media. Your MSA distributor can help you select the accessories that best suit your application requirements. | |
| Filter Cassette Case, 2-piece, 25 mm, pack of 50 | 695681 |
| Filter Cassette Case, 2-piece, 37 mm, pack of 12 | 625412 |
| Filter Cassette Case, 3-piece, 37 mm, pack of 10 | 449347 |
| 50 mm long Cowl for 25 mm Filter Cassette Case, pack of 5 | 695683 |
| 25 mm Support Pad (felt backup disc), pack of 100 | 695684 |
| 37 mm Support Pad (felt backup disc), pack of 25 | 449375 |
| 25 mm Cellulose Bands, jar of 60 | 484683 |
| 37 mm Cellulose Bands, jar of 60 | 625415 |
| 37 mm Stainless Steel Coupler for 3-piece filter cassette sampling used with cyclone assembly | 457392 |
| Plastic coupler for preweighed filter cassette sampling used with cyclone assembly | 457391 |
| Sampling Line Assembly (use with all pumps and filter cassette cases) | 456226 |
| 25 mm Filter Cassette Case Sampling Line Coupler, package of 10 | 695685 |
| 37 mm Filter Cassette Case Sampling Line Coupler, package of 3 | 459743 |
| Charcoal Filter Tubes (for use in in-line sampling to protect pumps from vapor damage) | 804403 |
| Supplemenarty Parts Kit (includes 3 Stainless Steel support screens, small brush, tweezers and press/pry tool) | 456246 |
| All-Glass Impinger Assembly (includes fritted-glass flask, inlet cap, nozzle and cap) | 10008396 |
| Bubbler for Fritted-Glass Flask | 10008397 |
| Flask Holster | 10008398 |
| Tubing for Flask | 93495 |
| Gas Sampling Bags | |
| Teflon Sample Bag Assembly | 471667 |
| Tedlar Sample Bag Assembly | 472992 |
![]() |
|
| A primary calibration device, the DigiCal Calibrator provides instantaneous calibration for instruments like the MSA Escort LC or the secondary flow standard inside the Escort ELF Sampling Pumps. Just press the plunger and the DigiCal Calibrator does the work. Its unique flow cell replaces conventional bubble tubes and makes calibration easier. The DigiCal Calibrator achieves extreme accuracy by utilizing a computerized flow meter that provides instantaneous flow readouts on a digital display. Accurate measurements are possible within +/- 0.5% at any altitude. |
|
| Primary Calibration Devices | |
| DigiCal Calibrator | 655101 |
| Air Inlet Caps, pkg of 2 | 655102 |
| 110 V Charger with AC Adapter | 655112 |
| Bubble Solution, 4 oz. bottle | 655273 |
| Sub C Battery Pack | 655169 |
| Secondary Calibration Devices | |
| Flowmeter for use with Flow-Lite and Escort Sampling Pumps, 0.2 to 4 lpm | 490197 |
| Flowmeter for use with Flow-Lite and Escort Sampling Pump with Gemini Twin-Port Sampler, 30 to 300 mlpm | 490198 |
![]() |
|
| This new MSA/SupelCo guide to sorbent tube sampling lists MSA part numbers. It is a very comprehensive guide to all types of air sampling using personal sampling pumps. | |
| MSA/SupelCo Sampling Chart | 814473 |
![]() |
|
| MSA's Ventilation Smoke Tube Kits are for use where controlled generation of a visible smoke is desired in order to determine the velocity of slow moving air currents and establish their direction and flow patterns in shafts, mines and tunnels. They can also be used in commercial buildings and industrial processing plants to determine velocity and flow patterns of heating, ventilating and air-conditioning systems. | |
| Ventilation Smoke Kit, including aspirator bulb, two rubber plugs, and six smoke producing tubes contained in plastic carrying case | 458481 |
| Ventilation Smoke Kit, including aspirator bulb, siz tube caps and two glass smoke producing tubes contained in plastic carrying case | 5607 |
| Ventilation Smoke Tubes, package of 12 | 458480 |
| Glass Smoke Tubes, package of 10 | 5645 |
| WSP home | Products | Suppliers |
| MSA index page | Previous MSA page | Next MSA page |