MSA SCBA Accessories

For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

Credit Card Images

MSA SCBA Traditional Part Number Ordering Information
SCBA Facepiece Cylinder EBS PASS/Redundant Alarm Carrier & Harness Part No.
Ultralite MMR Ultra Elite Medium 30 min. Stealth - Dragonfly IP w/ heat sensor Vulcan 10018584
Ultralite MMR Ultra Elite Medium 30 min. Stealth Quick-Fill Dragonfly IP w/ heat sensor Vulcan 10018585
Ultralite MMR Ultra Elite Medium 30 min. Stealth - ICM 2000 w/ heat sensor Vulcan 10024214
Ultralite MMR Ultra Elite Medium 30 min. Stealth - ICM 2000 Plus w/ heat sensor Vulcan 10024215
Custom 4500 MMR Ultra Elite Medium 30 min. Stealth - Dragonfly IP w/ heat sensor Vulcan 10018586
Custom 4500 MMR Ultra Elite Medium 30 min. Stealth Quick-Fill Dragonfly IP w/ heat sensor Vulcan 10018587
Custom 4500 MMR Ultra Elite Medium 30 min. Stealth - ICM 2000 w/ heat sensor Vulcan 10024216
Custom 4500 MMR Ultra Elite Medium 30 min. Stealth - ICM 2000 Plus w/ heat sensor Vulcan 10024217
Custom 4500 MMR Ultra Elite Medium 30 min. Stealth Quick-Fill ICM 2000 Plus w/ heat sensor Vulcan 10024218

More MSA SCBA Units
SCBA Facepiece Cylinder Head Harness Case Part No.
WorkMask MMR 2216 Ultra Elite Medium Aluminum - 10018488 -
WorkMask MMR 2216 Ultra Elite Medium 30 min. Fiberglass EZ-Don - 10018487
WorkMask II MMR 2216 Ultra Elite Medium Aluminum - 10024219 -
WorkMask II MMR 2216 Ultra Elite Medium Aluminum yes 10024270 -

MSA SCBA Accessories: Quick-Fill System
The patented Quick-Fill system lets MSA Air Mask users refill and trans-fill air cylinders while the SCBA is worn, without removing the air cylinder, even in IDLH atmospheres. Use this MSA exclusive option to:
  • Fill an SCBA cylinder from a mobile air compressor or cascade system in less than a minute
  • Trans-fill between two cylinders, providing an emergency Breathing System
  • Extend the air supply over longer duration, using a remote compressed air device

Because performance is not affected, MSA air masks retain NIOSH certification during use of the Quick-Fill System. It is available on Ultralite II and MMR and Custom 4500 II and MMR air masks, including dual purpose models

The Quick-Fill system uses a special adapter assembly. On belt mounted units, it's located on the regulator, while MMR units have a junction block and fitting installed on the gauge line. A Quick-Fill hose with a quick disconnect connects the air source to the adaper for air transfers.

Quick-Fill System ordering information
Description Part No.
Ultralite MMR Quick-Fill Kit (shoulder) for units purchased after 12/98 10020382
Custom 4500 MMR Quick-Fill Kit (shoulder) for unit purchased after 12/98 10020383
Quick-Fill adapter block only for shoulder mounted units purchased after 12/98 10020515
Ultralite MMR Quick-Fill Kit (shoulder) for units purchased before 12/98 495172
Custom 4500 MMR Quick-Fill Kit (shoulder) for units purchased before 12/98 495173
Quick-Fill male adapter assembly for Ultralite II 485417
Quick-Fill male adapter assembly for Custom 4500 II 485416
Quick-Fill Kit for ICM, Ultralite 10020382
Quick-Fill Kit for ICM, Custom 4500 10020383
Quick-Fill adapter only for ICM (less coupling) 10020515
Replacement Parts for the Quick-Fill System
EBS hose package, includes 3 foot emergency transfill hose in kevlar pouch 485366
Emergency transfill hose, less kevlar pouch 485331
Kevlar pouch 485390
Male stainless steel quick-disconnect with SAE-10 thread, complete with dust cover (also for use as a fitting for customized refilling systems) 485391
Female quick-disconnect with SAE-4 thread, complete with dust cover 485392

Quick-Fill Hoses
25 ft. lengths are stocked, other "custom lengths" are available upon a special material basis. All SAE fittings are for high pressure service. Female quick-disconnect fittings have dust covers.
Item 25 ft. 12 ft. 10 ft. 8 ft. 6 ft. 3 ft.
FQD X FQD 485332 802690 802689 802688 802687 485331
FQD X CGA-347 Outlet 487907 802677 802675 802673 802671 492796
FQD X CGA-347 CN 487909 802685 802683 802681 802679 487427
FQD X SAE-4 487906 802704 802703 802702 802701 802705K
FQD X CGA-346 Outlet 487908 802678 802676 802674 802672 492797
FQD X CGA-346 CN 487910 802686 802684 802682 802680 487428

Audi-Larm™ Assemblies Ordering Information
Description Part No.
Audi-Larm Assembly for Ultralite MMR Air Mask with Vulcan carrier 10012995
Audi-Larm Assembly for Ultralite MMR Air Mask with Black Rhino carrier 488897
Audi-Larm Assembly for Custom 4500 MMR Air Mask with Vulcan carrier 10012996
Audi-Larm Assembly for Custom 4500 MMR Air Mask with Black Rhino carrier 485851
Audi-Larm Assembly for Ultralite II BMR Air Mask with shoulder gauge line 10013338
Audi-Larm Assembly for Ultralite II BMR Air Mask less shoulder gauge line 807494
Audi-Larm Assembly for Custom 4500 II BMR Air Mask with shoulder gauge line 10013339
Audi-Larm Assembly for Custom 4500 II BMR Air Mask less shoulder gauge line 807492

Ordering Information for Breathing Tube Assemblies for Ultralite II and Custom 4500 II Air Masks
Description Part No.
PBI Neck Strap 801156
Breathing Tube Assembly 801165
DIN Thread Breathing Tube 803506
Wire-reinforced Breathing Tube 803433

Walkaway Mounting Bracket
This storage unit can be mounted with screws on rescue or fire vehicles or any permanent surface. The spring clips permit the wearer to strap on the apparatus unassisted. By stepping forward, the wearer steps out of the bracket.
Walkaway Mounting Bracket for Ultralite MMR or Custom 4500 II or Custom 4500 MMR Air Masks with 30 minute cylinder
Part No. 39851

Wall Mounted Case
Corrosion resistant, tough plastic case has a leakproof synthetic rubber bulb seal gasket. It protects breathing apparatus from sunlight, weather, dust and corrosive atmospheres.
Wall mounted case for Ultralite II and Ultralite MMR, 30 minute cylinder 695308
Wall mounted case for Custom 4500 II and Custom 4500 MMR, 30 minute cylinder 695796
Wall mounted case for Custom 4500 II and Custom 4500 MMR, 60 minute cylinder 695797

High Pressure Filling Hose
Provides a convenient means to connect and charge high pressure air into a high pressure 4500 psig cylinder
High Pressure Filling Hose Assembly 476105

Accessories for Filling Low-Pressure (2216 psig) Cylinders
Air Outlet Connection, complete with Gauge 68846
Air Coupler Tee 68850
Air Pigtail 68851
Low Pressure Air Filling Hose, 5 feet long 476156

RescueAire™ Portable Air Supply System
The RescueAire Portable Air Supply System is an emergency breathing system for use by Rapid Intervention Teams (RITs). This system consists of a 60 minute lightweight Stealth carbon cylinder with Quick-Fill® emergency breathing system supported by a flame and heat resistant carrying harness (made from Nomex and Kevlar materials). An optional use shoulder strap is provided for hands free carrying
RescueAire Portable Air Supply System 10020934

Personal Alert Safety Systems (PASS)
ICM 2000 & ICM 2000 Plus Dragonfly PASS
The ICM 2000 and ICM 2000 Plus are integrated Computer modules designed to meet the new NFPA-1982, 1998 Edition PASS standard and NFPA-1981, 1997 Edition SCBA requirements for redundant End-of-Service Time indicators (EOST).

The ICM 2000 is an all in one combination PASS and redundant alarm module that can be added to any MSA MMR or BMR SCBA. Simply remove the shoulder mounted pressure gauge and replace it with the ICM module.

The ICM 2000 Plus is an all in one combination PASS and redundant alarm with a built in computer system that digitally displays SCBA performance information. The ICM 2000 Plus also offers a data logging and data downloading capability to retrieve up to 30 hours of SCBA usage information. The data provides information about the time of use, air consumption rate, ambient temperature and alarm activation. Through the device's IR (Infrared) port, the data can be downloaded to a personal computer for future evaluation.

The Dragonfly PASS from MSA was among the first PASS devices designed to meet the stringent NFPA-1982, 1998 Edition standard.

This standard calls for automatic (hands off) activation of stand alone PASS devices as well as two jumps in pre-alarm volume. The Dragonfly PASS exceeds the standard by offering a range of pre-alarm volumes and tones to help users avoid unnecessary progression to full alarm. Super bright LED indicators provide visual indicators: green indicates normal operation; red "wig-wag" indicates pre-alarm; and continuous red indicate full alarm. In addtion, an easily accessible activation button allows users to summon help manually.

Integrated directly into your SCBA, the low profile Dragonfly IP PASS automatically activates when your MSA Air Mask's cylinder is opened. Because the pressure switch and all electronics are housed within the PASS, assembly is as easy as changing a pressure gauge. Note: for BMR SCBA manufactured before September 1999, an Audi-Larm, shoulder pads, and shoulder mounted gauge line must be purchased.

The stand alone Dragonfly PASS features a tethered key designed to be attached to your jump seat, locker or vehicle interior. Whe you jump to action, the key snaps off, and your Dragonfly SA PASS activates and is on guard, monitoring your every move. Once the job is complete, you can turn off your stand alone PASS simply by replacing the key and pressing reset twice.

Redundant Alarm
At the request of firefighters nationwide, the NFPA requires two low pressure warning indicators for SCBA to comply with NFPA-1981, 1997 Edition. The redundant low-pressure warning requirements was effective in September 1999.

When you open your Air Mask's cylinder valve, the Redundant Alarm activates, displaying pressure readings through an analog gauge. The Redundant Alarm is low profile and easily accessible, because it is built into your Air Mask and conveniently positioned at chest level.

Should cylinder pressure levels decrease to 1100 psig on high pressure Air Masks or 540 psig on low pressure, both audible and visual indicators activate. Alternately flashing red and amber LEDs, a flashing electroluminescent backlight and piercing 85 decibel bursts of sound continuously warn of low pressure levels.

Note: for BMR SCBA manufactured prior to September 1999, an Audi-Larm assembly, shoulder pads, and shoulder mounted gauge line must be purchased.

PASS & Redundant Alarm Ordering Information
ICM 2000 Plus
MMR SCBA Thermistor Part No. BMR SCBA Thermistor Part No.
Custom 4500 inactivated 10019875 Custom 4500 II inactivated 10019879
Custom 4500 activated 10019876 Custom 4500 II activated 10019880
Ultralite inactivated 10019877 Ultralite II inactivated 10019881
Ultralite activated 10019878 Ultralite II activated 10019882
ICM 2000
Custom 4500 without 10019857 Custom 4500 II without 10019871
Custom 4500 with 10019858 Custom 4500 II with 10019872
Ultralite without 10019859 Ultralite II without 10019873
Ultralite with 10019870 Ultralite II with 10019874
ICM 2000 Plus Kit
ICM 2000 Plus Kit, includes software and jeteye reader 10020979

Dragonfly PASS Units and Redundant Alarm Ordering Information
Dragonfly PASS Units
Dragonfly IP PASS, with heat sensor 10005048
Dragonfly IP PASS without heat sensor 10005049
Dragonfly SA PASS with heat sensor 10005071
Dragonfly SA PASS without heat sensor 10005072
Replacement key for SA (10 pack) 10013073
Replacement REHAB Key (10 pack) 10013072
Replacement key (less tether) 1 per 10018830
Redundant Alarm Kits
For MMR 2216 / 3000 psig Air Mask 10009770
For MMR 4500 psig Air Mask 10009771
For Ultralite II BMR Air Mask 10013249
For Custom 4500 BMR Air Mask 10013300
Rubber Gauge Line Tether 10016029

WSP home Products Suppliers
MSA index page Previous MSA page Next MSA page