Toximeter II Automatic Detector Tube Pump
Toximeter II Automatic Detector Tube Pump
The Toximeter II Automatic Detector Tube Pump makes the sampling process easier, allowing the user to preset the number of pump strokes from 1 to 250. Intrinsically safe, the automatic pump works with all MSA detector tubes. It can also be used as a sampling pump.
655585

Taximeter II Automatic Detector Tube Pump

Kwik-Draw Detector Tube Pumps
Kwik-Draw Tube Pump

MSA's Kwik-Draw and Kwik-Draw Deluxe Pumps can be used with an assortment of MSA's detector tubes to spot-test atmospheres for a wide variety of toxic substances. They are designed for one­hand operation and consistent delivery of a sample draw volume of 100 milliliters (ml).

488543

Kwik-Draw Basic Pump, with remote sampling adapter and carrying pouch

487500

Kwik-Draw Deluxe Pump, with remote sampling adapter, carrying pouch and end-of-stroke indicator

Accessories

73067

Sampling line, 10ft

73068

Sampling line, 25 ft

73069

Sampling line, 50 ft

87970

Remote Sampling Adapter, required for above sampling line

488780

Solvent-Resistant Sampling Line, 25 ft, with reel

488872

Tube Holder, required for 488780 line above

470321

Flue Gas Kit

Gas-Tester II H Detector Tube Pump
Gas-Tester 2 Detector Tube Pump
The Gas-Tester II H Pump is set for action by compressing the bellows. A pump stroke is started by pressing the release button. When the sample (100ml) is drawn through the tube, the end-of-stroke indicator changes color. An accurate measurement is obtained because the sample draw procedure itself is controlled only by the specifications of the pump and the flow resistance of the detector tube.

696944

Gas Tester II H Detector Tube Pump

Detector Tube Handbook
Detector Tube Handbook
813929 Detector Tube Handbook

Detector Tube Industry Action Sets
Industrial Detector Tube Sets

Agricultural Set
4 x Phosphine
2 x Sulfur Dioxide
4 x Methyl Bromide
2 x Hydrogen Cyanide
Pulp & Paper Set
3 x Chlorine Dioxide
2 x Sulfur Dioxide
3 x Hydrogen Sulfide
2 x Chlorine
2 x Ozone
Indoor Air Quality Set
2 x Carbon Monoxide
2 x Carbon Dioxide
2 x Formaldehyde
2 x Ozone
2 x H2O (relative humidity)
Pharmaceutical Set
3 x Acetic Acid
3 x Aromatic HC
3 x Qualitest
3 x Hydrogen Cyanide
Petroleum Set
2 x Hydrogen Sulfide
2 x Carbon Monoxide
2 x Qualitest
4x Benzene
2x Hexane
Mining Set
3 x Carbon Monoxide
2 x Nitrogen Dioxide
3 x Nitrous fumes
4 x Natural Gas/Methane
Synthetics Manufacturing Set
2 x Toluene
4 x Qualitest
2 x Ethanol
2 x Vinyl Chloride
2 x Trichloroethylene
Semiconductor Sets
Chemical Vapor Deposition Process

3 x Ammonia tubes
3x CO2 tubes
3 x Nitrous fumes tubes
3 x H2S tubes
Etching Process
4 x Ammonia tubes
4 x Chlorine tubes
4 x Hydrogen Chloride tubes
Epitaxy Process
3 x CO tubes
3 x Hydrogen Chloride tubes
3 x Phosphine tubes
3 x Phosgene tubes
Crystal Growth Process
6 x Phosgene tubes
6 x Phosphine tubes

Note: All sets are boxes of 12 tubes.

Agricultural Set

655864

Pulp and Paper Set

655868

Indoor Air Quality Set

710981

Pharmaceutical Set

655869

Petroleum Set

655865

Mining Set

655867

Synthetics Manufacturing Set

655866

Chemical Vapor Deposition Process Set

655933

Etching Process Set

655934

Epitaxy Process Set

655935

Crystal Growth Process Set

655931

Chemical Warfare Agent Detector Tubes
Chemica Warfare Agent Detector Tubes

Detect a wide range of nerve, blister, blood, and choking agents.

  • Quick, simple to use, easy to interpret results
  • "Go/No Go" style
  • Can be used with MSA's full line of pumps
  • All sold in boxes of 10 tubes
  • Important: Sold only in the U.S.

10007654

Nerve (Sarin, VX, GA, GO, etc.)

10007653

Blister (Mustard Gas)

10007650

Blister (Lewisite)

10007652

Blister (variety, including Mustard Gas)

10007651

Blood and Choking (CG, DP, AC, CK)

Chemical Warfare Agent Detector Tube Kits
Chemica Warfare Agent Detector Tube Kits

Chemical Warfare Kits are available in a Single CWA Tube Sampler and a Multi CWA Tube Sampler. The Single CWA Tube Sampler will only sample one CWA tube at a time. The Multi CWA Tube Sampler allows the user to simultaneously sample up to four CWA tubes at the same time without making adjustments. The kit is supplied with an MSA Escort ELF pump, which maintains constant flow with a built-in "Run/Hold" feature that allows the user to start/stop the pump and still maintain an accurate sampling timer. The four-port manifold tube holder is pre-set for the proper flow rate for CWA tube sampling.

10049765

Multi CWA Tube Sampler with Escort ELF Pump

10044998 Single CWA Tube Sampler with Kwik-Draw Pump

MSA Detector Tubes - Acetaldehyde through Chlorine

Substance Measured

Detector Tube
applicable

Part No.
(1 box of 10 tubes)

Measuring range
(ppm)

Threshold Limit Value
1998 ACGIH (ppm)

Acetaldehyde

Formaldehyde-0.l

497649

5-50

25 (ceiling)

Acetic Acid

Acetic Acid-l

804138

1-80

10

Acetone

Acetone-100

804141

100-10,000

500

Qualitest QL

497665

n/a

Acetylene dichloride, cis and trans
(1,2 Dichloroethylene)

Trichloroethane-5

487343

10-500

200

Qualitest QL

497665

n/a

Acetylene tetra bromide (1,1 ,2,2-Tetrabromoethane)

Trichloroethane-5

487343

5-200

1

Qualitest QL

497665

n/a

Acetylene tetrachloride (1,1,2,2- Tetrachloroethane)

Trichloroethane-5

487343

50-1000

1

Qualitest QL

497665

n/a

Ammonia

 

NH3-2

804405

2-500

25

NH3-20

800300

20-1000

NH3-0.1%

804406

0.1-10Vol.-%

n-Amyl chloride (l-Chloropentane)

Trichloroethane-5

487343

5-550

-

Benzene

 

 

Aromatic HC

804132

5-500

.5

 

 

C6H6-1

807024

1-100

C6H6-5

804411

5-100

Qualitest QL

497665

n/a

C6H6-0.5

655837*

0.5-10

Bromine

Cl2-0.2

803944

0.2-3

0.1

Bromobenzene

Aromatic HC

804132

30-720

-

Bromoethane (Ethyl bromide)

Trichloroethane-5

487343

15-400

5

Bromoform (Tribromomethane)

Trichloroethane-5

487343

7-200

0.5

Bromomethane (Methyl bromide)

Trichloroethane-5

487343

20-270

 

1,3-Butadiene

Ethylene-50

804428

100-1200

2

Qualitest QL

497665

n/a

n-Butane

Propane-200

804418

200-3800

800

Qualitest QL

497665

n/a

n-Butanol (Butyl Alcohol)

Ethanol-100

804136

100-3900

50 (ceiling)

sec. Butanol (sec-Butyl Alcohol)

Ethanol-100

804136

300-5100

100

l-Butene (l-Butylene)

Ethylene-50

804428

100-5000

 

Qualitest QL

497665

n/a

2-Butylene, cis and trans

Ethylene-50

804428

200-5000

-

(2-Butylene)

Qualitest QL

497665

n/a

 

Butyl Alcohol (n-Butanol)

Ethanol-100

804136

100-3900

50 (ceiling)

sec-Butyl Alcohol (sec-Butanol)

Ethanol-100

804136

300-5100

100

n-Butylamine

Triethylamine-5

804134

2-28

5 (ceiling)

iso-Butylamine

Triethylamine-5

804134

3-36

-

sec-Butylamine

Triethylamine-5

804134

2-18

-

t-Butylamine

Triethylamine-5

804134

2-14

-

n-Butylchloride (l-Chlorobutane)

Trichloroethane-5

487343

5-170

-

Qualitest QL

497665

n/a

l-Butylene (l-Butene)

Ethylene-50

804428

100-5000

-

Qualitest QL

497665

n/a

2-Butylene (2-Butene, cis and trans)

Ethylene-50

804428

200-5000

-

Qualitest QL

497665

n/a

n-Butyl mercaptan

Ethylmercaptan-0.5

804589

1.5-15

0.5

t-Butyl mercaptan

Ethylmercaptan-0.5

804589

0.8-5

 

Carbon Dioxide

CO2-100

497606

100-3000

5000

CO2-0.1%

487333

0.1-7.0 Vol.-%

CO2-1%

804419

1-20Vol.-%

Carbon Disulfide

CS2-2

492514

2-300

10

Qualitest QL

497665

n/a

Carbon Monoxide

CO-0.001 %

804421

0.001-0.3 Vol.-%

25

 

 

 

 

CO-5

803943

5-1000

CO-10

487334

10-3000

CO-3000

815507

3000-70000

CO-0.1%

804423

0.1-1.0Vol.-%

CO-0.3%

487335

0.3-7.0 Vol.-%

CO-10/color

47134

10-1000

(special orifice assembly for CO-10/color)

497652

 

Qualitest QL

497665

n/a

Chlorine

Cl2-0.2

803944

0.2-30

0.5

 

ClO2-0.05

804133

1-46

Cl2-50

655862

50-500