For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
||||
The Comfo Classic Respirator features SoftFeel facepiece material, which is an MSA-exclusive formulation that improves pliability and softness. Like earlier Comfo respirator models, the Comfo Classic Respirator features a unique face seal design that gives wearers an exceptional fit. NIOSH certified. |
||||
Comfo Classic Respirator |
||||
Material |
Color |
Small |
Medium |
Large |
Soft Feel Hycar |
Black |
808075 |
808074 |
808076 |
Soft Feel Silicone |
Black |
808072 |
808071 |
808073 |
![]() |
||||
The Comfo Elite Respirator provides protection against a variety of respiratory hazards. The Comfo Elite Respirator, available in black silicone, has a unique sealing surface designed to reduce facepiece slippage. The Comfo Elite Respirator comes in small, medium, and large sizes. NIOSH-certified. |
||||
Comfo Elite Respirator |
||||
Silicone |
Black |
490492 |
490491 |
490493 |
![]() |
||||
Ultra- Twin® Respirators |
||||
Material |
Color |
Small |
Medium |
Large |
Hycar |
Black |
471298 |
471286 |
471310 |
Silicone |
Black |
480263 |
480259 |
480267 |
![]() |
||||
The demand version of the Ultra Elite Facepiece from MSA can be used as a twin-cartridge airpurifying respirator for full-face respiratory protection. The unique lens design provides a high level of peripheral and downward vision. It is available in three sizes and has large adjustment tabs for easy donning and doffing. Choose one of two facepiece materials SoftFeel® Hycar Rubber or Silicone - to enhance wearer comfort. A speaking diaphragm in front of the wearer's mouth improves communication so that speech is not blocked. A nosecup reduces lens fogging in low temperatures or high-humidity conditions. NIOSH-certified. |
||||
Ultra Elite Facepiece |
||||
With Twin-Cartridge Adapter |
||||
Material |
Color |
Small |
Medium |
Large |
SoftFeel silicone |
Black |
10016755 |
10016756 |
10016757 |
Less Twin-Cartridge Adapter |
||||
Material |
Color |
Small |
Medium |
Large |
SoftFeel Hycar rubber |
Black |
493064 |
493020 |
493108 |
SoftFeel silicone |
Black |
493072 |
493028 |
493116 |
Note: Ultra Elite Facepieces must be fitted with a Twin-Cartridge Adapter to be used as a twin-cartridge respirator. |
|
|||
Twin-Cartridge Adapter - Converts demand Ultra Elite or Ultravue facepieces to twin-cartridge respirators. |
||||
Twin-Cartridge Adapter for Ultra Elite/Ultravue Facepieces |
803622 |
|||
The Comfo line of particulate, chemical and combination cartridges is NIOSH-approved (to 42 CFR, Part 84). Cartridges fit Comfo Classic, Comfo Elite, Ultra-Twin, Ultra Elite Twin-Cartridge and Duo-Twin Respirators. |
||||||||||||||||||
| Acid Gases | ||||||||||||||||||
MSA Cartridge Description |
Re-Order Part Number |
Color Coding |
Organic Vapor |
Chlorine | Sulfur Dioxide |
Chlorine Dioxide |
Hydrogen Chloride |
Hydrogen Sulfide |
Ammonia | Methyl Amine |
Form Aldehyde |
Hydrogen Fluoride |
Mercury Vapor |
Filter Types & Efficiency |
See Notes |
|||
| OV | CL | SD | CD | HC | HS* | AM | MA | FM | HF | MV | P100 | R95 | N95 | |||||
GMA(OV) |
464031 (10 in pkg.) |
X | X | X | 2,3 | |||||||||||||
GMA P100 |
815178 (6 in pkg.) |
X | X | 2,3,4 | ||||||||||||||
GMA P100 Short Stack |
815186 (6 in box) |
X | X | 2.3.4 | ||||||||||||||
GMB (AG) |
464032 (10 in box) |
X | X | X | X | X | X | 2 | ||||||||||
GMB P100 |
815179 (6 in box) |
X | X | X | X | X | 2,4 | |||||||||||
GMC (OV/AG) |
464046 (10 in pkg.) |
X | X | X | X | X | X | X | X | 2,3 | ||||||||
GMC P100 |
815180 (6 in box) |
X | X | X | X | X | X | X | 2,3,4 | |||||||||
GMC P100 Short Stack |
815188 (6 in box) |
X | X | X | X | X | X | X | 2,3,4 | |||||||||
GMD |
464033 (10 in box) |
X | X | X | X | 2,3 | ||||||||||||
GMD P100 |
815181 (6 in box) |
X | X | X | 2,3,4 | |||||||||||||
GME (Multigas) |
492790 (10 in box) |
X | X | X | X | X | X | X | X | X | X | X | X | 2,3 | ||||
GME P100 |
815182 (6 in box) |
X | X | X | X | X | X | X | X | X | X | X | 2,3,4 | |||||
GMI P100 |
815184 (6 in box) |
X | X | 2,4 | ||||||||||||||
Mersorb® |
466204 (10 in box) |
X | X | X | X | 2,4 | ||||||||||||
Mersorb P100 |
815185 (6 in box) |
X | X | X | 2,4 | |||||||||||||
P100 |
815175 (lOin box) |
X | 1,4 | |||||||||||||||
Sparkfoe® P100 |
815176 (10 in box) |
X | 1,4 | |||||||||||||||
Low-Profile P100 |
815177 (10 in box) |
X | 1,4 | |||||||||||||||
Stand-alone and cover |
816662 N95 (10 in pkg.) |
1 | ||||||||||||||||
Prefilter and Cover N95 |
816662 N95 (10 in pkg.) |
1 | ||||||||||||||||
Prefilter and Cover R95 |
816287 R95 (20 in box) |
1 | ||||||||||||||||
| Definitions N95-Particulate Filter (95% filter efficiency level) effective against particulate aerosols free of oil; time use restrictions may apply. R95-Particulate Filter (95% filter efficiency level) effective against all particulate aerosols; time use restrictions may apply. P100-Particulate Filter (99.97% filter efficiency level) effective against all particulate aerosols. |
||||||||||||||||||
Notes
|
||||||||||||||||||
* Escape only. |
||||||||||||||||||
An appropriate cartridge change-out schedule must be developed by a qualified professional, unless the cartridge/canister utilizes an end-of-service-life indicator. The change-out schedule must take into account all factors that may influence respiratory protection including specific work practices and other conditions unique to the worker's environment. If using against substances having poor warning properties, there is no secondary means of knowing when to replace the cartridges/canister. In such cases, take appropriate additional |
|||
Acrolein |
Hydrogen cyanide |
Nitric acid |
Phosphorus trichloride |
Aniline |
Hydrogen selenide |
Nitro compounds |
Stibine |
Arsine |
Methanol |
Nitrogen oxides |
Sulfur chloride |
Bromine |
Methyl bromide |
Nitroglycerin |
Urethane or other diisocyanate- containing paints |
Carbon monoxide |
Methyl chloride |
Nitromethane |
Vinyl chloride |
Diisocyanates |
Methylene chloride |
Phosgene |
|
Dimethyl sulfate |
Nickel carbonyl |
Phosphine |
|
![]() |
|||
| Cover Lens for Full Facepiece Respirators. Protects the facepiece lens from scratches during storage, handling and use. (top row, above) | |||
| Lens Shield for Advantage 1000. For added impact protection, a polycarbonate lens shield snaps into place. For nuclear personnel, the lens shield provides an additional level of eye protection and increased betaradiation protection. (bottom row, above) | |||
Cover Lens for Full Facepiece Respirators |
|||
Color |
No./Box |
Facepiece |
Part No. |
Clear |
25 |
Ultra Elite |
491500 |
Smoke-tinted |
25 |
Ultra Elite |
805456 |
Clear |
25 |
Ultravue |
456975 |
Smoke-tinted |
25 |
Ultravue |
480326 |
Clear |
25 |
Advantage 1000 |
813832 |
Clear |
25 |
Advantage |
10031542 |
Smoke-tinted |
25 |
Advantage |
10031543 |
Lens Shield for Advantage 1000 |
|||
Lens Color |
|
Small |
Medium/large |
Clear |
|
806463 |
806462 |
Tinted |
|
806465 |
806464 |
For simple, snap-on replacement of elastic headstraps with a cradle headband, for Comfo Classic and Comfo II Respirators. |
|
Cradle conversion kit |
479875 |
![]() |
|
Carrying Pouches |
|
Respirator Carrying Pouches and Carrying/Storage Case |
|
Carrying pouch for half-mask respirators |
468730 |
Carrying pouch for Advantage 1000 Respirator, black |
817040 |
![]() |
|
Respirator Carrying/Storage Case |
|
Black plastic carrying/storage case |
02056734 |
![]() |
|
The Twin-Cartridge Adapter converts demand Ultravue or Ultra Elite Facepieces to twin-cartridge respirators. The Cartridge Adapter allows use of threaded Comfo Cartridges on |
|
Cartridge Adapters |
|
Twin-Cartridge Adapter |
803622 |
Cartridge Adapter, package of 2 |
809999 |
![]() |
|
For use by workers who must wear corrective lenses, the Spectacle Kit can be easily inserted into the facepiece. The kit includes a wire support, rubber guide, and pair of metal-frame spectacles. Desired adjustment is obtained by moving the spectacles in and out of the rubber guide and up and down the wire support. The Advantage 1000 and the Ultravue/Ultra- Twin kits (S-7 shape, 44-mm lens size) and the Ultra Elite kit (S-7 shape, 48-mm lens size) fit Universal Bridge Corrective Lenses that can be obtained from local sources. The Spectacle Kit can be used with a nosecup. |
|
Ultra Elite Spectacle Kit (side wire support) |
804638 |
Ultra Elite Spectacle Kit (center support) |
493581 |
Advantage 1000 Spectacle Kit (side wire support) |
816137 |
Ultravue/Ultra- Twin Facepiece Spectacle Kit (side wire support) |
454819 |
![]() |
|
MSA Confidence Plus® Germicidal Cleaner Mix with warm water for a germicidal cleaner that is effective against various micro-organisms including immunodeficiency virus Type 1 (HIV-1, associated with AIDS). EPA-approved for use on safety equipment. |
|
Cleaning Accessories |
|
Canister with 220 towelettes, 4-1/4" x 6" |
697382 |
Box of 100 individually wrapped towelettes, 7-1/4" x 5" |
697383 |
"The Big Ones," Box of 50 individually wrapped towelettes, 8" x 11" |
10022871 |
MSA Confidence Plus Germicidal Cleaner, in 32 oz. bottle (not shown) |
10009971 |
![]() |
|
MSA Welder's Adapters are molded of polycarbonate plastic, which has high resistance to impact, heat, and welding splatter. The clip-on adapter attaches to the facepiece by molded-in clips. The integral adapter is attached by removing the facepiece lens and replacing it with the adapter. A large vision area - 4-1/2" x 5-1/4"- provides an unobstructed view of work. The Welder's Adapter is supplied with an impact-resistant cover lens; the desired filter plate is ordered separately. Rayfoe™ Filter Plates are available in four standard shades- 6,10,12,14. |
|
Clip-On Welder's Adapter for Ultravue and Ultra Twin Facepiece; with cover lens, less filter plate |
472859 |
Integral Welder's Adapter for Ultravue and Ultra Twin Facepiece; with cover lens, less filter plate |
470786 |
Clip-On Welder's Adapter for Ultra Elite Facepiece; with cover lens, less filter plate |
806482 |
Clip-On Welder's Adapter for Advantage 4200 Twin Port Facepiece; with cover lens, less filter plate |
10077063 |
Clip-On Welder's Adapterfor Advantage 4100 Single PORT 68,178,7,209,130,14648 |
|
Cover Lens |
88379 |
Welder's Hood, Kevlar |
486328 |
![]() |
|||
Molded from a soft rubber compound that is resistant to facial oils, the optional nosecup helps reduce lens fogging. |
|||
Nosecup (to reduce fogging) |
|||
Facepiece |
Small |
Medium |
Large |
Ultravue/Ultra- Twin, Black |
813138 |
813139 |
813140 |
Advantage 1000, Black |
806468 |
806466 |
806470 |
![]() |
|
The Occupational Safety and Health Administration (OSHA) requires fit tests to ensure proper fit for workers who use respirators. Quantitative testing methods rely on objective data to determine a proper fit. Qualitative fit-test methods are subjective in nature and rely on the judgment of the test subject. |
|
Bitrex Qualitative Fit-Test Kit |
|
Bitrex QLFT Kit |
697444 |
Replacement Fit-Test Solution |
697446 |
Sensitivity Solution |
697445 |
Replacement Hood |
697448 |
"Using the Qualitative Fit-Test Kit" videotape |
697449 |
Saccharin Qualitative Fit-Test Kit |
|
The Saccharin Qualitative Fit-Test Kit eliminates the need for special filters and is especially useful for dust/mist respirators. |
|
Saccharin QlFT Kit |
697287 |
Replacement Sensitivity Test Solution, 55 ml bottle |
697285 |
Replacement Fit-Test Solution, 55 ml bottle |
697286 |
Replacement Hood |
697448 |
"Using the Qualitative Fit Test Kit" videotape |
697325 |
Banana Oil Qualitative Fit-Test Kit |
|
MSA's Banana Oil Fit-Test Kit relies on a test subject's ability to detect a 95% pure solution of Isoamyl Acetate (banana oil). |
|
Qualitative Fit Test Kit |
801628 |
Qualitative Fit Test Kit, in rugged Pelican case |
801629 |
![]() |
|
All Models Available |
|
![]() |
|
| Above, left to right: QuikChek I Adapter QuikChek II Adapter QuikCheck III Adapter QuikChek IV Adapter |
|
OuikChek® I Adapter |
|
QuikChek I Fit-Test Adapter |
802710 |
Replacement Kit with 25 ft of sampling tubing and 25 connectors, clips, and suction cups |
803196 |
QuikChek II Fit-Test Adapter |
812022 |
Replacement Kit with 25 feet of sampling tubing and 25 connectors, clips and suction cups |
803196 |
OuikChek III FitTest Adapter |
805078 |
Replacement Kit with 25 ft of sampling tubing, 25 connectors, clip and suction cups |
803196 |
OptiFilter XL Cartridge (box of 6) |
496081 |
QuikChek IV Fit-Test Kit |
817446 |
Type H OptiFilter Cartridge (box of 6) |
491010 |
QuikChek Adapter for Advantage 1000 |
10006227 |
Advantage Fit Test Adapter (200 LS and 3200) |
10056424 |
![]() |
|
QuikChek® Adapter for Advantage 1000 Facepiece QuikChek Adapter converts a standard Advantage 1000 Facepiece to a probed respirator by replacing the speaking diap/p> |
|
QuikChek IV Fit-Test Kit |
817446 |
Type H OptiFilter Cartridge (box of 6) |
491010 |
QuikChek Adapter for Advantage 1000 |
10006227 |
Advantage Fit Test Adapter (200 LS and 3200) |
10056424 |
![]() |
|
QuikChek® Adapter for Advantage 1000 Facepiece QuikChek Adapter converts a standard Advantage 1000 Facepiece to a probed respirator by replacing the speaking diaphragm. (shown above left). |
|