For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
| • Small, lightweight design • Simultaneously monitors up to five atmospheric hazards: VOCs, H2S, CO, CO2, O2, PH#, NH3, NO2, HCN, CI2, CIO2, O2, SO2, PH3 and NH3 • Compatible with MicroDock II, Honeywell’s automatic test/calibration docking station • Available PID sensor enables sensitive broad spectrum monitoring of volatile organic compounds • Water-resistant, concussion-proof enclosure • User friendly—easy to operate and maintain with self-test, menu-driven interface, single-touch calibration • Audible, vibrating and visual alarms, with four alarm levels: instantaneous Low and High Alarm for all gases, TWA (time-weighted average) and STEL (short-term exposure limit) for VOCs and toxics • Continuous LCD shows simultaneous gas concentrations for five gases • Simple, user selectable field options including PID / combustible correction factor, language selection, confidence beep, span level, set TWA/STEL calculation choice, set calibration due date, pass code protection, latching alarm, “SAFE” display function, stealth mode, and selectable ppm resolution for some gases |
| DETECTOR: | 1 , 2, 3, 4, or 5 -gas detector | ||||||
| Gas / Sensor | Measuring Range | Default Resolution | High Resolution | TWA *** | STEL*** | LOW *** | HIGH*** |
| O2 | 0-30.0% | 0.50% | N/A | N/A | N/A | 19.5 | 23.5 |
| H2S | 0-500 ppm | 1.0 ppm | N/A | 10 | 15 | 10 | 15 |
| CO | 0-999 ppm | 1.0 ppm | N/A | 35 | 50 | 35 | 200 |
| TwinTox (H2S) | 0-500 ppm | 1.0 ppm | N/A | 10 | 15 | 10 | 15 |
| TwinTox (CO) | 0-500 ppm | 1.0 ppm | N/A | 35 | 50 | 35 | 200 |
| PH3 | 0-5.0 ppm | 1.0 ppm | 0.1 ppm | 0.3 | 1.0 | 0.3 | 1.0 |
| SO2 | 0-150 ppm | 1.0 ppm | 0.1 ppm | 2 | 5 | 2 | 5 |
| NO2 | 0-99.9 ppm | 1.0 ppm | 0.1 ppm | 2.0 | 5.0 | 2.0 | 5.0 |
| HCN | 0-30.0 ppm | 1.0 ppm | 0.1 ppm | 4.7 | 10.0 | 4.7 | 10.0 |
| Cl2 | 0-50.0 ppm | 1.0 ppm | 0.1 ppm | 0.5 | 1.0 | 0.5 | 1.0 |
| NH3 | 0-100 ppm | 1.0 ppm | 0.1 ppm | 25 | 35 | 25 | 50 |
| ClO2 | 0-1.00 ppm | 0.1 ppm | 0.01 ppm | 0.1 | 0.3 | 0.1 | 0.3 |
| O3 | 0-1.00 ppm | 0.1 ppm | 0.01 ppm | 0.1 | 0.1 | 0.1 | 0.1 |
| CO2 / IR | 0-50,000 ppm | 50 ppm | N/A | 5,000 | 30,000 | 5,000 | 30,000 |
| 0-5.0% v/v | 0.01% | N/A | 0.5% | 3.0% | 0.5% | 3.0% | |
| VOC / PID | 0-1000 ppm | 1 ppm | N/A | 50 | 100 | 50 | 100 |
| LEL | 0-100% LEL | 1% | N/A | N/A | N/A | 10% | 20% |
| 0-5.0% v/v | 0.1% | N/A | N/A | N/A | 0.5% | 1.0% | |
| Use: | Portable 5-gas monitor for the protection of personnel against gas hazards | ||||||
| Sensor Configuration*: | One oxygen, one flammable, one toxic (can be TwinTox CO/H2S sensor or other); final position is either toxic, PID or IR sensor | ||||||
| Display: | Custom LCD; Backlight: Low light (auto); alarm condition (auto); reactivation on demand | ||||||
| Weight: | 13.1 oz / 370 g | ||||||
| Dimensions: | 5.7 x 2.9 x 1.5 in/ 14.5 x 7.4 x 3.8 cm | ||||||
| Battery: | Alkaline or optional Lithium Polymer rechargeable battery | ||||||
| Audible Alarm: | 95 dB at 1 ft./30 cm at variable pulsed audible alarm | ||||||
| Vibrating Alarm: | Pulses warning in gas alarm conditions, or for any status alarms | ||||||
| Visual Alarm: | Two flashing alarm bars visible from all angles | ||||||
| Sensor Type: | Electrochemical, catalytic bead and optional Infrared or PID | ||||||
| Calibration: | Automatic (stand alone or with MicroDock II) | ||||||
| Data recording: | All events and occurrences (calibration zero adjustment, calibration span adjustment, gas readings, TWA, STEL, alarm condition, failures detected by the microprocessor) | ||||||
| Intrinsic Safety: | X5 and X5PID are II 1 G Ga Exia IIC T4 for ATEX and Ga Exia IIC T4 for IECEx; X5IR CO2 is II 2 G Ga Ex d ia IIC T4 for ATEX and Ga Ex d ia IIC T4 for IECEx; Canada and the U.S. : Class I, Div.1 Gr. A,B,C, D T4. Certified for combustible gas environments for Canada and the US: CAN/CSA C22.2 No.152 and ANSI ISA S12.13.1 |
||||||
| Warranty: | Two years including sensor except NH3 (one year) | ||||||
| * Contact Honeywell Analytics or a Honeywell Analytics distributor for allowable configurations *** Note: alarm setpoints may vary by region |
|||||||
| WSP home page | Products page | Suppliers page | |
| Gas Detectors | Lumidor Index | Previous Lumidor Page | Next Lumidor Page |