Lumidor Gas Detectors - New - Page 3

For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

Credit Card Images

To order this gas detector online, click this link: http://www.westernsafetystore.com/lumixpsigasd.html

MiniMAX XP Single Gas Detector
The MiniMAX XP is all about preferences. It delivers advanced, full feature functionality, user configurability with cost effective serviceability for a wide range of toxic gases. The market demands more than small size and good looks in a new generation single gas monitor.
A compact and rugged design, maintenance that's easy while providing simple operation is essential. With loud, ultrabright audiovisual alarm, XP demands attention when gas is detected. For noisy environments, a built-in vibrating alarm is supplied as standard.
XP delivers all of the above while still ensuring reliable, accurate readings and no false alarms from radio frequency interference (RFI). In addition, XP provides continuous gas readings, TWA/STEL and two instantaneous alarms with peak hold facility.
By using #SureCell™ sensors with TempraSURE™ thermal shock correction and Reflex™ sensor protection, XP ensures improved accuracy and reliability in adverse operating conditions.
Maintenance could not be easier. Built-in Cell Decay Compensation extends the time between calibrations to 12 months. With typical sensor life in excess of two years and three year battery life, operational costs are minimized. Batteries and sensors can be easily replaced by the user. Alternatively, Lumidor offers a wide range of service programs to meet customer needs.

Tough, durable housing
• Small and lightweight
• Rugged, impact and weather resistant
• Includes belt clip and lanyard or optional crocodile clip

Easy to use
• Works straight out of the box
• Single button on/off operation
• Intuitive icons suitable for all languages
• User configurable via menu
• Interactive product training guide available

Ultra clear backlight display
• Continuous reading of gas levels
• TWA/STEL and two instantaneous alarm levels
• Battery life, calibration and self-test status

Effective gas alarm indication
• Alarm and backlight combine to demand attention
• Distinctive 95 dB two-tone alarm
• Vibrating alarm supplied as standard

Reliable operation
• Self-test on start up or on demand checks display, battery, sensor, audiovisual and vibrating alarms
• Uses patented #SureCell™ and Reflex™ sensor technology
• Includes TempraSURE™ thermal compensation and shock protection
• Periodic flash and/or beep for increased confidence

Unsurpassed RFI/EMI performance
• No false alarms due to walkie talkies or cell phones
• Exceeds the toughest industrial standards for RFI immunity

Cost effective
• Fully inclusive 2 year warranty
• Cell decay compensation enables up to 12 months between calibrations (H2S & CO only)
• Replaceable sensor and battery
• Minimum 2 years sensor life
• Typical 3 year battery life (low battery warning)
• Initial and on-going running costs minimized

Gas Detection Specifications for MiniMAX XP
  Alarm Set Points
Gases Detected Range Level 1 Level 2 STEL TWA
Oxygen (O2) 0 to 30% v/v 23.5% v/v 19.5% v/v n/a n/a
Carbon Monoxide (CO) 0 to 999 ppm 35 ppm 100 ppm 400 ppm 35 ppm
Hydrogen Sulfide (H2S) 0 to 250 ppm 10 ppm 15 ppm 15 ppm 10 ppm
Sulfur Dioxide (SO2) 0 to 150 ppm 2 ppm 5 ppm 5 ppm 2 ppm
Chlorine (Cl2) 0 to 50 ppm 0.5 ppm 1 ppm 1 ppm 0.5 ppm
Hydrogen Cyanide (HCN) 0 to 150 ppm 5 ppm 10 ppm 10 ppm 5 ppm
Nitrogen Dioxide (NO2) 0 to 150 ppm 3 ppm 5 ppm 5 ppm 3 ppm
Ammonia (NH3) 0 to 100 ppm 25 ppm 50 ppm 35 ppm 25 ppm
Hydrogen (H2) 0 to 999 ppm 100 ppm 500 ppm n/a n/a

General Specifications for MiniMAX XP
General Serviceable, portable single gas monitor for personal protection agains oxygen and toxic gas hazards
Calibration Time between calibrations is minimized utilizing cell decay compensation facility. The maximum time between calibrations is 12 months
Operating Life Sensor (replaceable): Minimum of two years
Battery (replaceable): Three years
Operating Temperature -20ºC to +50ºC (-4ºF to +122ºF)
Humidity 5 - 95% RH (non-condensing)
Audible Alarm 95 dB at 10 cm (4 inches)
Visual Alarm High intensity red LEDs
Vibrating Alarm Standard
Display Ultra clear backlit LCD displays gas levels and instrument status
Sensor Type Electrochemical (replaceable)
Battery Type Lithium CR2, 3.0 volts (replaceable)
Diagnostics Self test of circuitry, battery, LCD and software. Sensor test using patented Reflex™ sensor technology
IP Rating IP54 (minimum)
Intrinsic Safety North America: Class 1, Div 1, Groups A, B, C, D, T4 (UL/cUL)
Europe: EEx ia IIB T4 (CENELEC) II 2G EEx ia IIC T4 (ATEX pending)
RFI/EMI EC EN50270:1999 and EN55011
Dimensions 93mm H x 50mm W x 27mm D
Weight Toxic: 81.5g (2.8 oz)
Oxygen: 93.0g (3.3 oz.)

WSP home page Products page Suppliers page  