For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
| Model 6518FR is a freeze resistant valve system with push button activation for use on all Haws single bubbler freeze resistant pedestal mounted fountains. Reliable, fully engineered sytem with pneumatic operated valve installed below frost line to drain water to non-freezing depth allowing fountain to function year-round. Assembly can be lifted to surface and lowered back into casing for easy maintenance without disturbing fountain. Automatic stream regulation with .45 GPM flow control assembly. Five cubic feet of porous gravel fill (see drawing below) is required for water left in supply line between valve and bubbler when valve is in off position to drain through check valve into ground. (If high water table, poor drainage or surface flooding is a consideration, see Haws Model 6519FR patented freeze resistant valve system). 1/2" NPT(M) inlet. Haws manufatures drinking fountains, electric water coolers and electric drinking fountains to be lead free by all known definitions including ANSI/NSF Standard 61, Section 9, California Proposition 65 and the Federal Safe Drinking Water Act.
Components: Valve: Model 5815, lead free, plastic check valve used on most Haws pedestal freeze resistant drinking fountain valve. 1/8" NPT(M) inlet. Options & Accessories (Additional Cost) Valve Box: Model 6625, ground box with lid for freeze resistant valve models 6518FR and 6518.2FR. |
![]() |
![]() |
| Model 6518.2FR is a freeze resistant valve system with push button activation for use on all Haws dual height two bubbler freeze resistant pedestal mounted fountains. Reliable, fully engineered system with two pneumatic operated valve installed below frost line to drain water to non-freezing depth allowing fountain to function year-round. Assembly can be lifted to surface and lowered back into casing for easy maintenance without disturbing fountain. Automatic stream regulation with two .40 GPM flow control assemblies. Five cubic feet of porous gravel fill is required for water left in supply line between valve and bubbler when valve is in off position to drain water through check valve into ground. 1/2" NPT(M) inlet. Haws manufatures drinking fountains, electric water coolers and electric drinking fountains to be lead free by all known definitions including ANSI/NSF Standard 61, Section 9, California Proposition 65 and the Federal Safe Drinking Water Act.
Components: Valve: Model 5815, lead free, plastic check valve used on most Haws pedestal freeze resistant drinking fountain valves. 1/8" NPT(M) inlet. Options & Accessories (Additional Cost) Valve Box: Model 6625, ground box with lid for freeze resistant valve models 6518FR and 6518.2FR. |
![]() |
![]() |
| Model 6519FR Enviro-Guard freeze resistant valve system is specially designed for areas with a high water table, poor drainage or surface flooding. This system can be used on all Haws outdoor single bubbler pedestal mounted fountains. Model 6519FR includes a main on-off valve for coupling an underground water supply conduit via a standpipe to a fountain head to dispense water. It comprises a sump chamber installed below the frost line with a piston mounted for reciprocal movement between advanced and retracted positions. It comes with a quick disconnect for rapid troubleshooting. When the main valve is turned off, the piston retracts by gravity within the sump chamber and residual water remaining within the standpipe drains to the sump chamber at low pressure through a normally open pressure valve mounted on the piston. When the main valve is turned on, the pressure valve is closed by water pressure and the piston is advanced with the sump chamber to expel the water previously collect through a discharge conduit coupled to the main fountain drain. Model 6519FR is made of corrosion reistant materials, and includes an air gap waste fitting assembly. Any residual water is not reused but is expelled to the waste line. Haws manufatures drinking fountains, electric water coolers and electric drinking fountains to be lead free by all known definitions including ANSI/NSF Standard 61, Section 9, California Proposition 65 and the Federal Safe Drinking Water Act.
Components: Valve: Model 5881, push button activated air valve. |
![]() |
![]() |
| Model 6521FR is a freeze resistant valve system with push buton activation for use on all Haws single bubbler freeze resistant wall mounted fountains. It is fully engineered with pneumatic operated valve installed on the inside wall where room temperature does not drop below 50ºF. When the valve goes to off position, water left in supply line between valve and bubbler drains back into waste inside cabinet. Allows fountain on outside to function year-round. Automatic stream regulation with .40 GPM flow control assembly. Included in cabinet is 1/2" NPT screwdriver stop and 1-1/4 NPT trap. Unit is efficient and easy to maintain. Haws manufatures drinking fountains, electric water coolers and electric drinking fountains to be lead free by all known definitions including ANSI/NSF Standard 61, Section 9, California Proposition 65 and the Federal Safe Drinking Water Act.
Components: Valve: Model 5881, push button activated air valve. |
![]() |
![]() |
| Model 6522FR is a freeze resistant valve system with push button activation for use on all Haws two bubbler freeze resistant wall mounted fountains. It is fully engineered with pneumatic operated valves installed on the inside wall (see drawing below) where room temperature does not drop below 50ºF. When valve goes to off positon, water left in supply line between valve and bubbler drains back into waste inside cabinet. Allows two bubbler fountain on outside to function year-round. Automatic stream regulation with two .40 GPM flow control assemblies. Included in cabinet is 1/2" NPT screwdriver stop and 1-1/4 NPT trap. Unit is efficient and easy to maintain. Haws manufatures drinking fountains, electric water coolers and electric drinking fountains to be lead free by all known definitions including ANSI/NSF Standard 61, Section 9, California Proposition 65 and the Federal Safe Drinking Water Act.
Components: Valve: Model 5881, push button activated air valve. |
![]() |
| WSP home page | Products page | Suppliers page | Emergency Showers & Eyewash |
| Haws Index | Previous Haws Page | Next Haws Page |