For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
| Model HRC remote chiller provides .5 gallon per hour of cold water. Chiller is designed to supply glassfiller in residential or office use where a minimal demand of cold water is required. The unit is manufactured with 1.5 quart stainless steel tank and water lines. A static condenser guarantees quiet operation. Model HRC includes a heavy gauge galvanized steel cabinet. The refrigeration system is balanced to provide low energy usage and a longer life assured by utilizing a high displacement compressor, a counterflow evaporator/chiller, efficient capillary sizing, a large capacity dryer-strainer and a fan cooled condenser with maximum heat exchange. A wire service cord and polarized plug are furnished. 115 V, 60 Hz. Environmentally friendly R134a refrigerant is controlled by a calibrated capillary tube. Air cooled remote chillers require air circulation for proper operation. Any chiller mounted under a counter must also be provided with adequate ventilation. When chiller is installed in wall, be certain that it can always be removed through opening without damaging either chiller or wall. Allow minimum 1" clearance and minimum 4" clearance on back side. Capacity is based on ARI standard rating condition of 50ºF drinking water, 80ºF inlet water and 90ºF room temperature. Multiple outlets: HRC is capable of supplying a maximum of 1 station (bubbler, glassfiller). Supply line to station should be adequately insulated and no farther than 7 feet from chiller. Components: Evaporator Chiller: Model HPD035920-SP, evaporator/chiller combination coil and tank type provides for a double wall construction. The combination tank/coil type evaporator is designed to store chilled water to meet peak demands for chilled water. Options & Accessories (Additional Cost) Remote Chiller: Model HRC21, 2.5 GPH remote chiller. |
![]() |
![]() |
| Model HCR8 remote chiller provides 8 gallons per hour of cold water. This remote can provide chilled water to a wide variety of fountains with modern styling. Chiller can be concealed under a counter, between or within walls (check local codes), or high on a wall or column. Ideally suited for factories, cafeterias, restaurants, schools and offices. Other uses could be for precooling for beverage dispensers and fountains, machine coolant cooling, photo and X-ray processing, laboratory experimental work, or a capacity booster for ice cube makers. Model HCR8 includes a heavy gauge galvanized steel cabinet. The refrigeration system is balanced to provide low energy usage and a longer life assured by utilizing a high displacement compressor, a counterflow evaporator/chiller, efficient capillary sizing, a large capacity dryer-strainer and a fan cooled condenser with maximum heat exchange. A wire service cord and polarized plug are furnished. 115 V, 60 Hz. Environmentally friendly R134a refrigerant is controlled by a calibrated capillary tube. Air cooled remote chillers require air circulation for proper operation. Any chiller mounted under a counter must also be provided with adequate ventilation. When chiller is installed in wall, be certain that it can always be removed through opening without damaging either chiller or wall. Allow minimum 1" clearance and minimum 4" clearance on back side. Capacity is based on ARI standard rating condition of 50ºF drinking water, 80ºF inlet water and 90ºF room temperature. Multiple outlets: HCR8 is capable of supplying a maximum of 2 stations (bubbler, glassfiller). Supply line to station should be adequately insulated and no farther than 7 feet from chiller.
Components: Evaporator Chiller: Model HPD035947-SP, evaporator/chiller with a design that combines counterflow cooling with efficient bonding of refrigerant coil and water coil for maximum heat transfer. All copper double wall construction meets government and commercial standards. Coil on coil evaporator/chiller is designed to provide for instantaneous cooling to meet a continuous demand for chilled water. Options & Accessories (Additional Cost) Remote Chiller: Model HCR10, 10 GPH remote chiller. |
![]() |
![]() |
| Model HCR10 remote chiller provides 10 gallons per hour of cold water. This remote can provide chilled water to a wide variety of fountains with modern styling. Chiller can be concealed under a counter, between or within walls (check local codes), or high on a wall or column. Ideally suited for factories, cafeterias, restaurants, schools and offices. Other uses could be for precooling for beverage dispensers and fountains, machine coolant cooling, photo and X-ray processing, laboratory experimental work, or a capacity booster for ice cube makers. Model HCR10 includes a heavy gauge galvanized steel cabinet. The refrigeration system is balanced to provide low energy usage and a longer life assured by utilizing a high displacement compressor, a counterflow evaporator/chiller, efficient capillary sizing, a large capacity dryer-strainer and a fan cooled condenser with maximum heat exchange. A wire service cord and polarized plug are furnished. 115 V, 60 Hz. Environmentally friendly R134a refrigerant is controlled by a calibrated capillary tube. Air cooled remote chillers require air circulation for proper operation. Any chiller mounted under a counter must also be provided with adequate ventilation. When chiller is installed in wall, be certain that it can always be removed through opening without damaging either chiller or wall. Allow minimum 1" clearance and minimum 4" clearance on back side. Capacity is based on ARI standard rating condition of 50ºF drinking water, 80ºF inlet water and 90ºF room temperature. Multiple outlets: HCR10 is capable of supplying a maximum of 2 stations (bubbler, glassfiller). Supply line to station should be adequately insulated and no farther than 7 feet from chiller.
Components: Evaporator Chiller: Model HPD035947-SP, evaporator/chiller with a design that combines counterflow cooling with efficient bonding of refrigerant coil and water coil for maximum heat transfer. All copper, double wall construction meets government and commercial standards. Coil on coil evaporator/chiller is designed to provide for instantaneous cooling to meet a continuous demand for chilled water. Options & Accessories (Additional Cost) Remote Chiller: Model HCR10.50, 220 volt 10 GPH remote chiller. |
![]() |