| INSTALLATION If remote chiller unit is physically placed against barrier or in enclosure of any kind, 4" air space must be allowed on all sides. For optimum performance locate chiller within 15 feet of fountain. OPERATING PRESSURES: Supply water - 105 psi maximum Dimensions 171/8"W x 71/16"D x 14"H Shipping weight: 35 lbs. NOTE: A service stop (not included) should be installed at the cooler inlet line. |
| CABINET Manufactured of rust-resistant heavy gauge galvanized steel. Front and rear panels removable for servicing. PLUMBING CONNECTIONS 1⁄4" O.D. stainless steel tubing inlet and outlet. ELECTRICAL CONNECTION 7⁄8" diameter opening for conduit connection. COOLING UNIT Tank style evaporator. Tank is stainless steel, with drain plug. Fully insulated. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of evaporator/chiller storage water. Factory set for 40°F water. Adjustable to 50°. CONDENSER Copper/aluminum construction. REFRIGERATION SYSTEM Completely sealed; refrigerant R134A. Finned tube condenser air-cooled by fan motor. Hermetically sealed motor-compressor; lifetime lubricated; built-in overload protector. Test pressures, highside 325 psig., lowside 140 psig. Protected by the Halsey Taylor 5-year warranty. VENTILATION This unit is suitable for installation underneath a conventional kitchen sink, in a cabinet not less than 36" (914mm) wide (inside dimension). Two air openings with a minimum of 40" square (1016mm/square) each, minimum of 75% open area, must be provided in the cabinet. One opening must be in the overhang of the toe space and the other opening near the top of the cabinet. The remote unit must be installed with a minimum of 3" clearance between the unit and the rear wall of the cabinet. It can be installed flush against either side wall of the cabinet. The side louvers which are not against the cabinet must not be blocked by objects located within 4" (102mm) of the louvers. In addition, a minimum of 1" to 2" (25 to 51mm) clearance must be provided between the toe space air opening and the front of the unit. NOTE: Continued product improvement makes specifications subject to change without notice. ELECTRICAL Furnished with 6" leads enclosed in junction box for direct connection to standard 115 volt, 60 Hz, single phase. SUGGESTED SPECIFICATIONS Shall deliver 1.3 GPH of 50°F water at 90°F ambient and 80°F inlet water. Designed for use with any drinking fountain. Compressor shall be hermetically sealed. Manufacturer shall certify unit to be lead free as defined by the Safe Drinking Water Act. System controlled by adjustable thermostat. Complies with ARI Standard 1010. Unit can service 1 fountain. Locate chiller within 15 feet of fountain for optimum performance. |
![]() SJ5-Q |
![]() SJ8-Q |
![]() SJ10-Q |
![]() |
| CABINET Manufactured of rust-resistant heavy gauge galvanized steel. Removable service panels. PLUMBING CONNECTIONS 3⁄8" O.D. inlet and outlet (SJ5-Q and SJ10-Q) 1⁄4" O.D. inlet and outlet (SJ8-Q) ELECTRICAL CONNECTION 7⁄8" diameter opening for conduit connection. COOLING COIL AND STORAGE TANK Combination tube/tank type. Tube portion is continuous coil of copper-tubing. TEMPERATURE CONTROL Thermostat for cooling and storage tank is factory set for 50° F water. Adjustable ± 5° F. FAN MOTOR Unit bearing self-lubricating type for maintenance-free longer life. CONDENSER Copper/aluminum construction with associated shroud. REFRIGERATION SYSTEM Completely sealed; refrigerant R134A. Finned tube condenser air-cooled by fan motor. Hermetically sealed motor-compressor; lifetime lubricated; built-in overload protector. Test pressures, highside 325 psig., lowside 140 psig. Protected by the Halsey Taylor 5-year warranty. ELECTRICAL Furnished with 6" leads enclosed in junction box for direct connection to standard 115 volt, 60 Hz, single phase. VENTILATION SJ8-Q When mounting unit in an open area, to insure proper ventilation, maintain a 4" (102mm) clearance from cabinet louvers on each side of cooler. When mounting unit in a cavity or behind a wall, maintain a minumum space of 4" (102mm) on each side, 4" (102mm) on the top and a depth of 12" (305mm). SJ5-Q and SJ10-Q It is important to insure proper ventilation. Allow a minimum clearace of 6" (152mm) in front and 3" (76mm) in the rear of the unit. If unit is to be installed in an enclosure, allow the following clearances around unit: 1 inch (25mm) on each side, 3 inches (76mm) in the rear and 3 inches (76mm) inches above wall. NOTE: Continued product improvement makes specifications subject to change without notice. SUGGESTED SPECIFICATIONS Shall deliver ( ) GPH of 50°F water at 90°F ambient and 80°F inlet water. Designed for use with any drinking fountain. Compressor shall be hermetically sealed. Manufacturer shall certify unit to be lead free as defined by the Safe Drinking Water Act. System controlled by adjustable thermostat. Complies with ARI Standard 1010. SJ5 can serve 1 fountain SJ8 can serve 2 fountains SJ10 can serve 3 fountains Locate chiller within 15 feet of fountain for optimum performance. |
![]() |
![]() |
| MODEL: SJ19-Q Dimensions 23˝ W x 101/4˝D x 253/4˝H Minimum Wall Opening 261/4˝ W x 14˝D x 30˝H Shipping weight: 130 lbs. OPERATING PRESSURES: Supply water - 105 psi maximum NOTE: A service supply stop (not included) should be installed at the cooler inlet line. |
| CABINET Manufactured of rust-resistant heavy gauge galvanized steel. Removable service panels. PLUMBING CONNECTIONS 3⁄8" O.D. inlet and outlet. ELECTRICAL CONNECTION 7⁄8" diameter opening for conduit connection. COOLING COIL AND STORAGE TANK Combination tube/tank type. Tube portion is continuous coil of copper-tubing. TEMPERATURE CONTROL Thermostat for cooling and storage tank is factory set for 50° F water. Adjustable ± 5° F. FAN MOTOR Unit bearing self-lubricating type for maintenance-free longer life. CONDENSER Copper/aluminum construction with associated shroud. REFRIGERATION SYSTEM Completely sealed; refrigerant R134A. Finned tube condenser air-cooled by fan motor. Hermetically sealed motor-compressor; lifetime lubricated; built-in overload protector. Test pressures, highside 375 psig., lowside 150 psig. Protected by the Halsey Taylor 5-year warranty. ELECTRICAL Furnished with 6" leads enclosed in junction box for direct connection to standard 115 volt, 60 Hz, single phase. VENTILATION It is important to insure proper ventilation. Allow a minimum clearace of 12" (305mm) in the front and 3" (76mm) in the rear of the unit. If unit is to be installed in an enclosure, allow the following clearances around unit: 1 inch (25mm) on each side, 3 inches (76mm) in the rear and 3 inches (76mm) inches above wall. NOTE: Continued product improvement makes specifications subject to change without notice. SUGGESTED SPECIFICATIONS Shall deliver 19 GPH of 50°F water at 90°F ambient and 80°F inlet water. Designed for use with any drinking fountain. Compressor shall be hermetically sealed. Manufacturer shall certify unit to be lead free as defined by the Safe Drinking Water Act. System controlled by adjustable thermostat. Complies with ARI Standard 1010. SJ19 can serve 3 fountains Locate chiller within 15 feet of fountain for optimum performance. |
![]() |
![]() |
| INSTALLATION A minimum clearance of 6" in front and back of unit is required to insure proper ventilation. OPERATING PRESSURES: Supply water - 105 psi maximum Dimensions 331⁄4"W x 133⁄4"D x 16"H Shipping weight: 125 lbs. |
| CABINET Manufactured of rust-resistant heavy gauge galvanized steel. Removable service panels. PLUMBING CONNECTIONS 3⁄8" O.D. stainless steel tubing inlet and outlet. ELECTRICAL CONNECTION 7⁄8" diameter opening for conduit connection. COOLING UNIT Combination tube-tank type. Tube portion is continuous coil of copper tubing. Tank is stainless steel. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of evaporator/chiller storage water. Factory set for 40°F water. Adjustable to 50°. FAN MOTOR Unit bearing self-lubricating type for maintenance-free longer life. CONDENSER Copper/aluminum construction with aluminum fins. DRAIN PLUG Provided with drain plug with O-ring seal. REFRIGERATION SYSTEM Completely sealed; refrigerant R134A. Finned tube condenser air-cooled by fan motor.Hermetically sealed motor-compressor with starting capacitor; lifetime lubricated; built-in overload protector. Test pressures, highside 375 psig., lowside 150 psig. Protected by the Halsey Taylor 5-year warranty. VENTILATION It is important to insure proper ventilation. A minimum of 6 inches (152mm) to the front must be maintained, and 6 inches (152mm) to the rear of the unit. NOTE: Continued product improvement makes specifications subject to change without notice. ELECTRICAL Furnished with 6" leads enclosed in junction box for direct connection to standard 115 volt, 60 Hz, single phase. SUGGESTED SPECIFICATIONS Shall deliver 29.5 GPH of 50°F water at 90°F ambient and 80°F inlet water. Designed for use where large quantity of chilled water is required. Compressor shall be hermetically sealed. Manufacturer shall certify unit to be lead free as defined by the Safe Drinking Water Act. System controlled by adjustable thermostat. Complies with ARI Standard 1010. SJ30 can serve 3 fountains Locate chiller within 15 feet of fountain for optimum performance. |
![]() |
![]() |
| INSTALLATION A minimum clearance of 6" in front and back of unit is required to insure proper ventilation. OPERATING PRESSURES: Supply water - 105 psi maximum Dimensions 331⁄4"W x 133⁄4"D x 16"H Shipping weight: 125 |
| CABINET Manufactured of rust-resistant heavy gauge galvanized steel. Removable service panels. PLUMBING CONNECTIONS 3⁄8˝ O.D. stainless steel tubing inlet and outlet. ELECTRICAL CONNECTION 7⁄8˝ diameter opening for conduit connection. COOLING UNIT Combination tube-tank type. Tube portion is continuous coil of copper tubing. Tank is stainless steel. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of evaporator/chiller storage water. Factory set for 40°F water. Adjustable to 50°. FAN MOTOR Unit bearing self-lubricating type for maintenance-free longer life. CONDENSER Water cooled copper condenser with maximum heat exchange. DRAIN PLUG Provided with drain plug with O-ring seal. REFRIGERATION SYSTEM Completely sealed; refrigerant R134A. Finned tube condenser is water cooled. Hermetically sealed motor-compressor with starting capacitor; lifetime lubricated; built-in overload protector. Test pressures, highside 375 psig., lowside 150 psig. Protected by the Halsey Taylor 5-year warranty. VENTILATION It is important to insure proper ventilation. A minimum of 6 inches (152mm) to the front must be maintained, and 6 inches (152mm) to the rear of the unit. NOTE: Continued product improvement makes specifications subject to change without notice. ELECTRICAL Furnished with 6" leads enclosed in junction box for direct connection to standard 115 volt, 60 Hz, single phase. SUGGESTED SPECIFICATIONS Shall deliver 31.9 GPH of 50°F water at 90°F ambient and 80°F inlet water. Designed for use where large quantity of chilled water is required. Compressor shall be hermetically sealed. Manufacturer shall certify unit to be lead free as defined by the Safe Drinking Water Act. System controlled by adjustable thermostat. Complies with ARI Standard 1010. SJ32W can serve 3 fountains Locate chiller within 15 feet of fountain for optimum performance. |
![]() 26784C Grill Cover |
| 26784C / 26785C Grill • Grill for covering opening of the 42518 wall box assembly • Designed for use with the SJ5-Q, SJ10-Q and SJ19-Q chillers • Specify part number 26784C when ordering stainless steel grill • Specify part number 26785C when ordering platinum vinyl grill |
![]() 42505 Shelf and Cover |
| 42505 Shelf and Cover • Shelf and cover designed to allow SJ5-Q, SJ10-Q and SJ19-Q chillers to be mounted on a wall • Kit includes platinum vinyl cover, galvanized steel shelf, steel angle brackets, mounting bracket and screws • Shipping Weight: 44 lbs. Use part #734250548410 when ordering. |
![]() 42518 Wall Box Assembly |
| 42518 Wall Box Assembly • Galvanized steel enclosed box frame • Designed for use with the SJ5-Q, SJ10-Q and SJ19-Q chillers • Kit includes panels, screws and bracket hangar • Grill cover must be ordered separately • Shipping Weight: 38 lbs. Use part #734251843730 when ordering. |
![]() |
![]() 42612 Wall Box Assembly |
| 42612 Wall Box Assembly • Allows SJ8-Q chiller to be mounted behind a wall • Kit includes open stainless steel frame, stainless steel grill, and cradle (shelf with hooks and screws) • Shipping Weight: 20 lbs. Use part #734261251550 when ordering. |
![]() 27107 Shelf |
| 27107 Shelf • Allows SJ8-Q chiller to be mounted on a wall • Stainless steel shelf designed for use with the SJ8-Q chiller so chiller can be mounted on a wall • No cover available • Shipping Weight: 15 lbs. Use part #732710751550 when ordering. |
![]() |
![]() |
| GENERAL Kit containing all pieces necessary for field installation attachment of glass filler into the openings on all glass filler accessible Halsey Taylor units. For HAC, WM, SW, SCWT, and XP series units. Installation requires a 3/4" hole punched in basin in field. Kit may also be factory installed. Labor extra. For HTV and S Series units factory installed only. FEATURES • Bright polished stainless steel construction glass filler with push down lever handle • 3/8" NPS supply • 100% Lead Free • Dimensions: 8-1/8" height, 3-1/8" overall width • Shipping Weight: 1 lb. KIT CONSISTS OF: • Gooseneck glass filler and lever • 1/4 inch polytube • 1/4 inch tube connector • 1/4 inch tee tube connector • Bubbler nipple • Gasket • Instruction manual Use part #96852CA when ordering. |
![]() |
| GENERAL Bright polished stainless steel construction glass filler with push lever handle fits 8880, 5801, RC8, BFMR and RWM8 units. Factory installed only. FEATURES • Bright polished stainless steel construction with push lever • 3/8˝ NPS supply • 100% Lead Free Dimensions: 3-3/8˝ overall length, 1-1/4˝ overall width, and 2-1/2˝ overall height Weight: 1 lb. Use part #73-02408-51-640 when ordering. |
![]() |
| GENERAL Designed to remove cysts, such as cryptrosporidium and giardia, lead particles, chlorine, taste and odor. Features include Quick Disconnect fittings on each end of the in-line filter. The filter contains a carbon block with lead sorbent media and the housing is made of rust and corrosion free plastic. Lead and cyst reduction filter shall be Halsey Taylor Aqua Sentry HWF142. Designed specifically for use with HTV Series (Voyager) water coolers but can be used on most Halsey Taylor models where space is a concern. RECOMMENDED USE CONDITIONS Capacity ......................750 Gallons (2,800 £) Flow rate .....................0.5gpm (1.9 l/m) Temperature................40-100°F (5 - 38°C) Maximum Pressure.....105psi (7.3 Kg/cm2) Minimum Pressure......40psi (2.8 Kg/cm2) PERFORMANCE TEST CONDITIONS* Capacity ......................750 Gallons (2,800 £) Flow rate .....................0.5gpm (1.9 l/m) Pressure......................60psi (4.2 Kg/cm2) Temperature................68-70°F (20-21°C) *Performance will vary depending on local water conditions. WATER CONNECTION • Water Inlet for 1⁄4" O.D. Tube • Water Outlet for 1⁄4" O.D. Tube STANDARDS Tested and certified by NSF International, the widely recognized and respected independent certification organization for public health safety. This filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst. KIT CONSISTS OF: • Filter • Mounting Bracket and Screw • 1/4" Polytubing • 3/8" Copper Tube • Quick Connect Union • Performance Data Sheet Shipping Weight: 2 lbs. 56191C REPLACEMENT FILTER Replacement filter for Aqua Sentry. Replacement instructions included. INSTALLATION INSTRUCTIONS The filter must be installed in compliance with all state and local laws and regulations governing the installation and use of this product. Disconnect electrical power and close water supply valve before proceeding. The filter must be installed on the water inlet line. Flow indicator (arrow) on filter should point in the same direction as the water flow. After installing new filter, open water supply valve and check for leaks. Flush system sufficiently (approximately 3 minutes) to effectively remove small residue of carbon fines. NOTE: A water shutoff valve should be installed on the incoming water line to aid in future servicing of filter. CAUTION • Filter is designed to reduce lead from incoming water to levels below EPA requirements. Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. • Use on water inlet line only. Do not allow installed filter to freeze. Do not attached hot water line to filter. • Filter should be replaced every 750 gallons (2,800 liters) or approximately 6 months after installation. |
![]() |
| GENERAL Designed to remove cysts, such as cryptrosporidium and giardia, lead particles and chlorine. Also reduces odors and discoloration from incoming water. Features include Quick-Disconnect, 1⁄4 turn installation. Automatic inlet shut-off valve that closes when filter is removed. Outer protective wrap. Spun Polypropylene prefilter mesh to prevent large, coarse sediment and particles from entering and clogging filter media. High-grade filter is made with activated carbon and patented ATS lead-removal media. Radial flow-thru design provides more surface area for untreated water while final filter mesh prevents loose carbon from entering water. Cap and housing shall be made of rust and corrosion free plastic. Lead and cyst reduction filter shall be Halsey Taylor Water Sentry VII. Designed specifically for use with the following series of Halsey Taylor water coolers: HAC, HACBL, WM**, SCWT** series, S series and WMBL. Can also be used on OVLSER, OVLER, HT, HRF, RC & BFMR units but must be mounted into the wall behind the unit’s backplate. CANNOT be used in the HTV, SW, WC, HBW, RWM or the unrefrigerated versions of the HT, HRF and OVL series. **For water cooled models contact the factory. RECOMMENDED USE CONDITIONS Capacity ......................1,500 Gallons (5678 £) Flow rate .....................0.75gpm (2.8 l/m) Temperature................40-120°F (4 - 49°C) Maximum Pressure.....105psi (724 Kpa) Minimum Pressure......20psi (138 Kpa) PERFORMANCE TEST CONDITIONS* Capacity ......................1,500 Gallons (5678 £) Flow rate .....................0.75gpm (2.8 l/m) Pressure......................60psi (4.2 Kg/cm2) Temperature................68-70°F (20-21°C) *Performance will vary depending on local water conditions. WATER CONNECTION • Water Inlet for 3⁄8" O.D. Tube • Water Outlet for 1⁄4" O.D. Tube STANDARDS Tested and certified by NSF International, the widely recognized and respected independent certification organization for public health safety. This filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, Particulate, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst. KIT CONSISTS OF: • Filter • Filter head • Mounting bracket • 1/4" polytubing, connectors and screws • Installation instructions • Performance Data Sheet Shipping Weight: 4 lbs. 92640C FILTER MONITOR Optional accessory monitors the number of gallons used for determining when to change filter. Monitor operates on one 9 volt alkaline battery. Not included. Installation instructions included. 55897C REPLACEMENT FILTER Replacement filter for Water Sentry VII. Replacement instructions included. Filter should be replaced every 1,500 gallons (5678 liters) or approximately one (1) year after installation. Use part # 55897C when ordering replacement filter. INSTALLATION INSTRUCTIONS The filter must be installed in compliance with all state and local laws and regulations governing the installation and use of this product. Disconnect electrical power and close water supply valve before proceeding. The filter must be installed on the water inlet line. Flow indicator (arrow) on filter should point in the same direction as the water flow. After installing new filter, open water supply valve and check for leaks. Flush system sufficiently (approximately 3 minutes) to effectively remove small residue of carbon fines. NOTE: A water shutoff valve should be installed on the incoming water line to aid in future servicing of filter. CAUTION • Filter is designed to reduce lead from incoming water to levels below EPA requirements. Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. • Use on water inlet line only. Do not allow installed filter to freeze. Do not attached hot water line to filter. • Filter should be replaced every 1,500 gallons (5678 liters) or approximately one (1) year after installation. |
![]() |
| GENERAL For use on SCWT and S series floor model units only where natural drainage is not available. Waste water from cooler drains into reservoir and is automatically pumped out to an overhead drain or other method of drainage. Silent 1/6 hp motor delivers 28 gph (maximum) at 40 ft. height through a 1/2" O.D. copper waste tube (not supplied). Unit is furnished with knockout for conduit (hardwire) connection to 115 volt, 60 Hz single phase electrical supply. Overall dimensions: 9-1/4" H x 6" W x 12" L. Shipping Weight: 16 lbs. KIT CONSISTS OF: • Sump Pump • Mounting strap • Trap mounting plate • Copper tubing • Connection fittings • Assorted screws, nuts & washers • Installation and operating instructions Note: Power cord and plug are not included. Sump Pump is hardwired. Water cooler must be level to avoid excess vibration. Use part #73-15213-51-550 when ordering. |
|
| GENERAL This kit contains a sufficient quantity of pieces for field modification of Halsey Taylor drinking fountains and water coolers to make units more tamper-resistant. For: HTV, HAC, HT, HRF, WC, WM, SW, SCWT, and OVL series single basin units. Refer to service manual for detailed instructions specific to each series. For general installation instructions see back of this spec sheet. KIT CONSISTS OF: • Chrome plated heavy duty unleaded brass vandal-resistant bubbler • 2 Vandal-resistant lock washers • 1 Bubbler nipple • 30 Vandal-resistant screws • 2 Drive bits Use part #98030C when ordering. 1. Remove fountain or cooler panel to gain access to the bubbler fitting from underneath the basin. |
![]() |
| 09855 KIT GENERAL This kit will modify units to make them more vandal-resistant by replacing existing drain plug with vandal-resistant version. Will fit all units with 2-7/8" drain opening. KIT CONSISTS OF: • Drain plug tapped and drilled for allen-head screw (included) • Strainer plate Use part #60-09855-51-640 when ordering. 98032C KIT |
![]() |
| 14703 Foot Pedal Kit GENERAL Kit contains all necessary material for installing fully operable foot pedal on all Halsey Taylor SCWT free-standing models (except coffee bar and water cooled units). Can be installed easily on-site. KIT CONSISTS OF: • Push rod • Foot pedal • Toe plate • Mounting bracket • Assorted hardware • Installation instructions Shipping Weight: 2.75 lbs. Use part #73-14703-51-550 when |
![]() |
| Remodeling Panel Kit GENERAL Designed as an easily installed trim piece to further enhance the ability of the Halsey Taylor HTV and HAC Series of barrier-free coolers to retrofit many different styles of water coolers by Halsey Taylor and other manufacturers. FEATURES • Attractive gray color blends with any decor • Constructed of durable rust and corrosion resistant ABS • Allows for increased retrofit applications • Size: 30" H x 21" W For use with Halsey Taylor models: HTV-4-Q, HTV-8-Q, HTV-8EE-Q, HAC8FS-Q CHILD, HAC8EE-Q CHILD KIT CONSISTS OF: • Panel • Installation instructions |
|
| 1. Shut off water supply to fountain. 2. Determine location for installation of Hose Bib Accessory. Remove existing access cover plate. (This accessory is designed to replace the existing access cover). 3. Disconnect the fountain water line from the main water supply. Connect Tube (Item 8) to existing fountain strainer as shown below. 4. Connect Tee (Item 6) to Tube (Item 8). Connect main water supply to Tee using 1/2" Copper Tube (Item 9). DO NOT TURN MAIN WATER SUPPLY ON AT THIS TIME! 5. Connect Hose Bib Accessory water line to the Tee and to the Elbow (Item 5) on the Access Panel (Item 3) using 1/2" Copper Tube (Item 7) as shown below, maintain loop in coil to facilitate installation and removal of Access Panel. 6. Turn on main water supply. Check for leaks. If there are leaks, turn off main water supply and correct the water leaks as required. After insuring that all connections are leak free, leave main water supply on and replace any panels that may have been removed in the installation process. 7. Assemble Hose Bib Accessory to the main fountain body. |
![]() |
![]() |
| GENERAL Makes rough-in and installation easier for all models of non-freeze resistant Endura II tubular fountains. Opening in adaptor allows for simplified routing of water supply and drain into the fountain body. 3/4" rods provide added stability. Steel adaptor features textured powder-coat finish, and E-coat immersion which coats the outside and inside of the adaptor for the ultimate in corrosion protection. KIT CONSISTS OF: • Adapter Panel • (3) 3/4" Rods • Assorted hardware (nuts, bolts and washers) needed for installation • Installation instructions Shipping Weight: 40 lbs. Use part #97890C when ordering INSTALLATION INSTRUCTIONS |