8880 Fully Recessed Fountain
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing and for size of wall cut out. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.) Installation requires trap to be installed in wall. A service supply stop must be installed at the fountain inlet line. Trap and service stop not included. NOTE: Supply line between fountain and cuspidor to be furnished and installed by contractor.
OPERATING PRESSURES
Supply water-105 psi maximum
GENERAL
Fully recessed fountain, non-corrosive stainless steel number 300 series with brushed satin finish. One-piece, contour-formed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Ideally suited for installation in high traffic areas. Model meets state and federal requirements as defined by the Americans with Disabilities Act for side/parallel approach.
BUBBLER
Exclusive one-piece, chrome-plated twostream mound-building bubbler with nonremovable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/2" tube outlet for 1-1/2" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front, contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. Fountain shall comply with ADA for parallel approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

8880 with 10245 Fully Recessed Fountain and Cuspidor
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing and for size of wall cut out. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.) Installation requires trap to be installed in wall. A service supply stop must be installed at the fountain inlet line. Trap and service stop not included. NOTE: Supply line between fountain and cuspidor to be furnished and installed by contractor.
OPERATING PRESSURES
Supply water-105 psi maximum. Cuspidor water pressure must be 40 lbs. minimum.
GENERAL
Fully recessed fountain, non-corrosive stainless steel number 300 series with brushed satin finish. One-piece, contour-formed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Cuspidor may be mounted to right or left of fountain. Ideally suited for installation in high traffic areas. Model meets state and federal requirements as defined by the Americans with Disabilities Act for side/parallel approach.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting. Cuspidor flushing jet operates when drinking fountain is actuated.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/2" tube outlet for 1-1/2" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front, contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. Fountain shall comply with ADA for parallel approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

2634 Anniversary Fountain
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing and for size of wall cut out. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.) Installation requires trap to be installed in wall. A service stop (not included) must be installed at the fountain inlet line.
OPERATING PRESSURES
Supply water-105 psi maximum
GENERAL
Semi-recessed fountain, made of White Marblyte™ solid surface non-porous polymer. Contour-formed basin with smooth corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" trap furnished.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front, contour-formed basin to eliminate splashing and standing water, and shall have smooth corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. Fountain shall comply with ADA for parallel approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4592 Face Mounted Fountain
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing. For wall support required locations see installation instructions provided with fountain. Bolt fountain securely to wall per installation instructions. Water supply and waste line are to be assembled as required. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.) Installation requires trap to be installed in wall. A service supply stop must be installed at the fountain inlet line. Trap and service stop not included. CAUTION – Fountain must be securely bolted to wall
OPERATING PRESSURES
Supply water-105 psi maximum
GENERAL
Face-mounted, weather-resistant exposed Sierra™ stone aggregate fountain for year-round beauty with minimum maintenance. Contourformed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
BUBBLER
Exclusive one-piece, vandal-resistant chromeplated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front. Shall include contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4592 FR Freeze Resistant Stone Fountain
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of freeze-resistant system and plumbing. For wall support required locations see installation instructions provided with fountain. Bolt fountain securely to wall per installation instructions. Water supply and waste line are to be assembled as required. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.) CAUTION – Fountain must be securely bolted to wall
OPERATING PRESSURES
Supply water-105 psi maximum Freeze-resistant box must be installed on interior non-freezing wall. NOTE: A service supply stop (not included) should be installed at the fountain inlet line.
IMPORTANT: For recommended wall support see installation instructions provided with fountain.
GENERAL
Face-mounted, weather-resistant exposed Sierra™ stone aggregate fountain for year-round beauty with minimum maintenance. Contourformed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
FREEZE-RESISTANT VALVE SYSTEM
Freeze-resistant system features box that installs behind non-freezing wall for housing water connection from the stop to the strainer.
BUBBLER
Exclusive one-piece, vandal-resistant, chromeplated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing into freeze-resistant box.
DRAIN OUTLET
1-1/4" waste outlet located in freeze-resistant
valve system.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front. Shall include contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

5405 Face Mounted Fountain
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing. For wall support required locations see installation instructions provided with fountain. Water service line and waste line are to be assembled as required. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.) NOTE: A service supply stop (not included) should be installed at the fountain inlet line. CAUTION – Fountain must be securely bolted to wall.
OPERATING PRESSURES
Supply water-105 psi maximum
GENERAL
Face-mounted, one-piece fountain made of durable, non-corrosive, molded white composite material. Contour-formed basin with softly rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
BUBBLER
Single-stream angle jet bubbler. Combination self-closing push-button type, with integral automatic stream regulator and hood guard.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front, contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

5701 Wall Mounted Fountain
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing. For wall support required locations see installation instructions provided with fountain. Water service line and waste line are to be assembled as required. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.) Trap and service stop not included. CAUTION – Fountain must be securely bolted to wall
OPERATING PRESSURES
Supply water-105 psi maximum NOTE: A service supply stop (not included) must be installed at the fountain inlet line.
GENERAL
One-piece backsplash and basin made of non-corrosive stainless steel. Anti-splash ridge to reduce splatter. Contour design insures proper drainage and prevents standing waste water. Satin finish resists stains and corrosion and is easy to maintain. Model meets state and federal requirements as designed by the Americans with Disabilities Act for side/parallel approach.
BUBBLER
Exclusive two-stream mound-building bubbler with non-removable anti-squirt feature insures a more comfortable and satisfying drink of water. One-piece, chrome-plated unit has integral hood guard design to prevent contamination.
PUSHBAR ACTUATION MECHANISM
Self closing light touch push bars with raised letters for the visually impaired.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front, contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. *Fountain shall comply with ADA for parallel approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4400 Pedestal Fountain
LEGEND
A = 3/8˝ O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL (8˝ x 10˝)

MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Provide solid, well-drained surface to mount pedestal fountain (concrete pad recommended.) (6) 1⁄2" anchor bolts (not included) should be attached securely to mounting surface in order to secure fountain. (Refer to rough-in diagram.) Locate and install plumbing through ground as required. NOTE: Fountain is not furnished with service valve. Assemble mounting brackets to pedestal base with bolts provided. Position pedestal over plumbing and secure base to anchor bolts. Remove access panels and connect supply and water lines. Turn on water supply and check for leaks. Stream height is factory set at 45-50 psi. If water pressure varies greatly from this, adjust automatic stream regulator to provide drinking stream approximately 11⁄2" above projector guard. Reassemble access panels to pedestal. Trap and service stop not included.
OPERATING PRESSURES:
Supply water - 105 psi maximum

GENERAL
Pedestal, Endura II™ Steel fountain with textured powder coat finish and E-Coat immersion for year-round beauty with minimum maintenance. The E-Coat immersion process coats the outside and inside of the fountain for the ultimate in corrosion protection. Contourformed stainless steel basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Ideally suited for installation in public areas.
BUBBLER
Vandal-resistant bubbler is one-piece, chrome-plated, with integral hood guard design to prevent contamination from other users, airborne deposits and tampering.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
ACCESS PANEL
Manufactured of heavy-gauge steel with vandalresistant screws. Provides access for easy hook-up of all plumbing connections.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front. Shall include contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be chrome-plated vandal-resistant type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4400 FR Freeze Resistant Pedestal Fountain
MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Site and drainage excavation is required for fountain installation. Refer to owner’s manual for site preparation details. Provide solid, well-drained surface to mount pedestal fountain (concrete pad recommended). (6) 1⁄2" anchor bolts (not included) should be attached firmly to mounting surface in order to secure fountain. Refer to rough-in diagram and be sure to allow an opening for the freeze-resistant valve in the ground as shown in the installation instructions that accompany the fountain. Refer to local codes for any additional requirements. NOTE: Fountain is not furnished with service valve. Assemble fountain to prepared site and mounting pad. Position pedestal over plumbing and secure base to anchor bolts. Remove access panels and connect supply and water lines. Turn on water supply and check for leaks. Refer to owner’s manual for detailed instructions.
OPERATING PRESSURES:
Supply water - 105 psi maximum
GENERAL
Pedestal, Endura II™ Steel fountain with textured powder coat finish and E-Coat immersion for year-round beauty with minimum maintenance. The E-Coat immersion process coats the outside and inside of the fountain for the ultimate in corrosion protection. Contour formed stainless steel basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Ideally suited for installation in public areas.
FREEZE-RESISTANT VALVE SYSTEM
Freeze-resistant valve designed for ground installation 18˝ below the frost line. 60˝ of access tubing provided with the freeze-resistant valve system. The length of the tubing can be adjusted in the field for lesser frost depths.
BUBBLER
Vandal-resistant bubbler is one-piece, chrome-plated, with integral hood guard design to prevent contamination from other users, airborne deposits and tampering.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
WATER INLET
3/8" female NPT fitting
DRAIN OUTLET
Drain requirements are detailed in the owner’s manual.
ACCESS PANEL
Manufactured of heavy-gauge steel with vandalresistant screws. Provides access for easy hook-up of all plumbing connections.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front. Shall include contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be chrome-plated vandal-resistant type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4400 Sanitary FR Sanitary Freeze Resistant Pedestal Fountain
MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Site and drainage excavation is required for fountain installation. Refer to owner’s manual for site preparation details. Provide solid, well-drained surface to mount pedestal fountain (concrete pad recommended). (6) 1⁄2" anchor bolts (not included) should be attached firmly to mounting surface in order to secure fountain. Refer to rough-in diagram and be sure to allow an opening for the freeze-resistant valve in the ground as shown in the installation instructions that accompany the fountain. Refer to local codes for any additional requirements. NOTE: Fountain is not furnished with service valve. Assemble fountain to prepared site and mounting pad. Position pedestal over plumbing and secure base to anchor bolts. Remove access panels and connect supply and water lines. Turn on water supply and check for leaks. Refer to owner’s manual for detailed instructions.
OPERATING PRESSURES:
Supply water - 105 psi maximum
GENERAL
Pedestal, Endura II™ Steel fountain with textured powder coat finish and E-Coat immersion for year-round beauty with minimum maintenance. The E-Coat immersion process coats the outside and inside of the fountain for the ultimate in corrosion protection. Contour formed stainless steel basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Ideally suited for installation in public areas.
SANITARY FREEZE-RESISTANT VALVE SYSTEM
Fully sealed assembly minimizes chance of ground water contamination, and prevents drain water from mixing with fresh water. Freeze-resistant valve designed for ground installation 18" below the frost line.
BUBBLER
Vandal-resistant bubbler is one-piece, chrome-plated, with integral hood guard design to prevent contamination from other users, airborne deposits and tampering.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Stream height regulator is located inside sanitary freeze-resistant valve system to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
WATER INLET
1/2" male NPT fitting.
DRAIN OUTLET
Drain requirements are detailed in the owner’s manual.
ACCESS PANEL
Manufactured of heavy-gauge steel with vandalresistant screws. Provides access for easy hook-up of all plumbing connections.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front. Shall include contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be chrome-plated vandal-resistant type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
NOTE: Continued product improvement makes specifications subject to change without notice.

4400 DB Pedestal Fountain with Pet Fountain
MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Provide solid, well-drained surface to mount pedestal fountain (concrete pad recommended.) (8) 1⁄2" anchor bolts (not included) should be attached securely to mounting surface in order to secure fountain. (Refer to rough-in diagram.) Locate and install plumbing through ground as required. NOTE: Fountain is not furnished with service valve. Assemble mounting brackets to pedestal base with bolts provided. Position pedestal over plumbing and secure base to anchor bolts. Remove access panels and connect supply and water lines. Turn on water supply and check for leaks. Stream height is factory set at 45-50 psi. If water pressure varies greatly from this, adjust automatic stream regulator to provide drinking stream approximately 11⁄2" above projector guard. Modified low stream height bubbler for pet fountain. Reassemble access panels to pedestal. Trap and service stop not included.
OPERATING PRESSURES:
Supply water - 105 psi maximum
GENERAL
Pedestal, Endura II™ Steel fountain with textured powder coat finish and E-Coat immersion for year-round beauty with minimum maintenance. The E-Coat immersion process coats the outside and inside of the fountain for the ultimate in corrosion protection. Contour formed stainless steel basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Pet fountain features slow drainage for easy drinking. Ideally suited for installation in public areas.
BUBBLER
Vandal-resistant bubblers are one-piece, chrome-plated, with integral hood guard design to prevent contamination from other users, airborne deposits and tampering.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbuttons do not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
ACCESS PANEL
Manufactured of heavy-gauge steel with vandalresistant screws. Provides access for easy hook-up of all plumbing connections.
SUGGESTED SPECIFICATIONS
Fountain shall have a lower doggy bowl for use by pets and shall include pushbuttons on the front and side. Shall include contour-formed basins to eliminate splashing and standing water, and shall have rounded corners and edges. Projectors shall be chrome-plated vandalresistant type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4460 Yard Hydrant
MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Provide solid, well-drained surface to mount hydrant (concrete pad recommended.) (6) 1⁄2" anchor bolts (not included) should be attached securely to mounting surface in order to secure fountain. (Refer to rough-in diagram.) Locate and install plumbing through ground as required. NOTE: Hydrant is not furnished with service valve. Assemble mounting brackets to hydrant base with bolts provided. Position hydrant over plumbing and secure base to anchor bolts. Remove access panels and connect supply and water lines. Turn on water supply and check for leaks. Reassemble access panels to pedestal. Refer to owners’ manual for detailed instructions.
OPERATING PRESSURES:
Supply water - 105 psi maximum Hydrant is rated for inlet water pressure of 20-105 psi. A pressure reducing regulator should be used if the inlet water supply exceeds 105 psi.
NOTE: Not designed for sub-freezing applications.
GENERAL
Pedestal, Endura II™ Steel yard hydrant with textured powder coat finish and E-Coat immersion for year-round beauty with minimum maintenance. The E-Coat immersion process coats the outside and inside of the hydrant for the ultimate in corrosion protection. Hydrant provides ability to connect garden hoses or fill pails in outdoor applications. Ideal for golf courses, ball parks and swimming pools for irrigation purposes. This hydrant is rated for inlet water pressure of 20-105 psi. Model 4460 is hydrant with non-locking hose bib. Model 4461
includes panel and a door that can be secured with a standard padlock (not included).
WATER INLET
1/2" O.D. Tubing
SUGGESTED SPECIFICATIONS
Hydrant shall include 10" domed cap with vandal resistant screws. Model 4460 has access panel with recessed hose bib. Model 4461 has access panel with recessed hose bib and a door that can be secured with a standad padlock (not included). Not designed for sub-freezing applications.
Note: Continued product improvement makes specifications subject to change without notice.

4591 Stone Upright Pedestal Fountain
MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Provide solid, well-drained surface to mount pedestal fountain (concrete pad recommended). (4) 1/2" anchor bolts (not included) should be attached securely to mounting surface in order to secure fountain. (Refer to rough-in diagram.) Locate and install plumbing through ground as required. NOTE: Fountain is not furnished with service valve. Assemble mounting brackets to pedestal base with bolts provided. Position pedestal over plumbing and sure base to anchor bolts. Remove access panels and connect supply and water lines. Remember to check you local plumbing and other applicable codes before installation. Turn on water supply, check for leaks. Reassemble access panels to pedestal. Trap and service stop not included.
OPERATING PRESSURES
Supply water-105 psi maximum
GENERAL
Pedestal, weather-resistant exposed Sierra™ stone aggregate fountain for year-round beauty with minimum maintenance. Contour-formed stainless steel basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
BUBBLER
Single-stream, self-closing, pushbutton operated with integral volume control for maintaining proper stream height. Also includes hood guard and anti-squirt feature.
ACCESS PANEL
Manufactured of heavy-gauge steel with vandal-resistant self-locking screws. Baked on enamel protective coating is resistant to wear, moisture, and sunlight. Provides access for easy hookup of all plumbing connections.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall be upright pedestal with exposed Sierra™ stone aggregate. Shall include contour formed stainless steel basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be single-stream with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4715 Steel Upright Pedestal Fountain
MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Provide solid, well-drained surface to mount pedestal fountain (concrete pad recommended.) (4) 3/8" anchor bolts (not included) should be attached securely to mounting surface in order to secure fountain. (Refer to rough-in diagram.) Locate and install plumbing through ground as required. NOTE: Fountain is not furnished with service valve. Position pedestal over plumbing and secure base to anchor bolts. Remove access panels and connect supply and water lines. Turn on water supply and check for leaks. Reassemble access panels to pedestal. Trap and service stop not included.
OPERATING PRESSURES
Supply water - 20 psi minimum to 105 psi maximum.
GENERAL
Pedestal, Endura™ steel fountain with textured powder coat finish and E-Coat immersion for year-round beauty with minimum maintenance. The E-Coat immersion process coats the outside and inside of the fountain for the ultimate in corrosion protection. Contourformed stainless steel basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
BUBBLER
Exclusive one-piece, vandal-resistant, chromeplated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
ACCESS PANEL
Manufactured of heavy-gauge steel with vandal resistant screws. Provides access for easy hook-up of all plumbing connections.
SUGGESTED SPECIFICATIONS
Fountain shall be upright pedestal, Endura™ Steel with powder coat epoxy finish. Shall include pushbutton on the front. Shall include stainless steel contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be twostream, mound-building type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4715 FR Freeze Resistant Steel Upright Pedestal Fountain
MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Site and drainage excavation is required for fountain installation. Refer to owner’s manual for site preparation details. Provide solid, well-drained surface to mount pedestal fountain (concrete pad recommended). (4) 1⁄2" anchor bolts (not included) should be attached firmly to mounting surface in order to secure fountain. Refer to rough-in diagram and be sure to allow an opening for the freeze-resistant valve in the ground as shown in the installation instructions that accompany the fountain. Refer to local codes for any additional requirements. NOTE: Fountain is not furnished with service valve. Assemble fountain to prepared site and mounting pad. Position pedestal over plumbing and secure base to anchor bolts. Remove access panels and connect supply and water lines. Turn on water supply and check for leaks. Refer to owner’s manual for detailed instructions.
OPERATING PRESSURES
Supply water - 20 psi minimum to 105 psi maximum.
GENERAL
Pedestal, Endura™ steel fountain with textured powder coat finish and E-Coat immersion for year-round beauty with minimum maintenance. The E-Coat immersion process coats the outside and inside of the fountain for the ultimate in corrosion protection. Contour formed stainless steel basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
FREEZE-RESISTANT VALVE SYSTEM
Freeze-resistant valve designed for ground installation 18" below the frost line. 60" of access tubing provided with the freeze-resistant valve system. The length of the tubing can be adjusted in the field for lesser frost depths.
BUBBLER
Exclusive one-piece, vandal-resistant, chromeplated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
WATER INLET
3/8" female NPT fitting
DRAIN OUTLET
1-1/4" tube outlet. Drain requirements are detailed in owner’s manual.
ACCESS PANEL
Manufactured of heavy-gauge steel with vandal-resistant screws. Provides access for easy hook-up of all plumbing connections.
SUGGESTED SPECIFICATIONS
Fountain shall be upright pedestal, Endura™ Steel with powder coat epoxy finish. Shall include pushbutton on the front. Shall include stainless steel contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be twostream, mound-building type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4715 Sanitary FR Freeze Resistant Sanitary Steel Pedestal Fountain
MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Site and drainage excavation is required for fountain installation. Refer to owner’s manual for site preparation details. Provide solid, well-drained surface to mount pedestal fountain (concrete pad recommended). (4) 1⁄2" anchor bolts (not included) should be attached firmly to mounting surface in order to secure fountain. Refer to rough-in diagram and be sure to allow an opening for the freeze-resistant valve in the ground as shown in the installation instructions that accompany the fountain. Refer to local codes for any additional requirements. NOTE: Fountain is not furnished with service valve. Assemble fountain to prepared site and mounting pad. Position pedestal over plumbing and secure base to anchor bolts. Remove access panels and connect supply and water lines. Turn on water supply and check for leaks. Refer to owner’s manual for detailed instructions.
OPERATING PRESSURES:
Supply water - 20 psi minimum to 105 psi maximum.
GENERAL
Pedestal, Endura™ steel fountain with textured powder coat finish and E-Coat immersion for year-round beauty with minimum maintenance. The E-Coat immersion process coats the outside and inside of the fountain for the ultimate in corrosion protection. Contour formed stainless steel basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
SANITARY FREEZE-RESISTANT VALVE SYSTEM
Fully sealed assembly minimizes chance of ground water contamination, and prevents drain water from mixing with fresh water. Freeze-resistant valve designed for ground installation 18" below the frost line.
BUBBLER
Exclusive one-piece, vandal-resistant, chromeplated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Stream height regulator is located inside sanitary freeze-resistant valve system to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
WATER INLET
1/2" male NPT fitting.
DRAIN OUTLET
1-1/4" tube outlet. Drain requirements are detailed in owner’s manual.
ACCESS PANEL
Manufactured of heavy-gauge steel with vandal-resistant screws. Provides access for easy hook-up of all plumbing connections.
SUGGESTED SPECIFICATIONS
Fountain shall be upright pedestal, Endura™ Steel with powder coat epoxy finish. Shall include pushbutton on the front. Shall include stainless steel contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two stream, mound-building type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
NOTE: Continued product improvement makes specifications subject to change without notice.

4520-68 Cast Iron Pedestal Fountain
MOUNTING INSTRUCTIONS
• Provide solid, well-drained surface to mount fountain.
• Locate and install plumbing through ground as shown in rough-in. Note: Fountain is not furnished with service valve.
• Locate three tripod mounting holes as shown on rough-in. Mounting bolts not furnished – 7/16" diameter holes provided in tripod.
• Remove set screw in side of tripod cover and raise cover to aid in positioning fountain over mounting holes. Support cover with blocking while making plumbing connections.
• Use unions to connect supply and waste lines.
• Anchor tripod to ground.
• Turn on water supply and check for water leaks.
• Lower tripod cover, align hole for set screw and tighten set screw into leg of tripod.
• Stream height is factory set at 45-50 psi. Trap and service stop not included.
OPERATING PRESSURES:
Supply water- 20 psi minimum to 105 psi maximum.
GENERAL
Pedestal, cast iron closed base with forest green enamel finish for year-round beauty with minimum maintenance. Contour-formed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Model 4520-68 is 30" high and Model 4521-68 is 36" high
BUBBLER
Single-stream, self-closing, pushbutton operated with integral volume control for maintaining proper stream height. Also includes hood guard and anti-squirt feature.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front. Shall include contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be single-stream type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4616 Cast Iron Pedestal Fountain
MOUNTING INSTRUCTIONS
• Provide solid, well-drained surface to mount fountain.
• Locate and install plumbing through ground as shown in rough-in. Note: Fountain is not furnished with service valve.
• Locate three tripod mounting holes as shown on rough-in. Mounting bolts not furnished – 7/16" diameter holes provided in tripod.
• Remove set screw in side of tripod cover and raise cover to aid in positioning fountain over mounting holes. Support cover with blocking while making plumbing connections.
• Use unions to connect supply and waste lines.
• Anchor tripod to ground.
• Turn on water supply and check for water leaks.
• Lower tripod cover, align hole for set screw and tighten set screw into leg of tripod.
• Stream height is factory set at 45-50 psi. Trap and service stop not included.
OPERATING PRESSURES:
Supply water- 20 psi minimum to 105 psi maximum.
GENERAL
Pedestal, cast iron closed base with forest green enamel finish for year-round beauty with minimum maintenance. Contour-formed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Model 4616 is 30" high and Model 4617 is 36" high
BUBBLER
Single-stream, self-closing, pushbutton operated with integral volume control for maintaining proper stream height. Also includes hood guard and anti-squirt feature.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front. Shall include contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be single-stream type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

4880 FR Freeze Resistant Pedestal Fountain
MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Site and drainage excavation is required for fountain installation. Refer to owner’s manual for site preparation details. Provide solid, well-drained surface to mount pedestal fountain (concrete pad recommended). (3) 1⁄2" anchor bolts (not included) should be attached firmly to mounting surface in order to secure fountain. Refer to rough-in diagram and be sure to allow an opening for the freeze-resistant valve in the ground as shown in the installation instructions that accompany the valve system. Refer to local codes for any additional requirements. NOTE: Fountain is not furnished with service valve. Assemble fountain to prepared site and mounting pad. Position pedestal over plumbing and secure base to anchor bolts. Remove access panels and connect supply and water lines. Turn on water supply and check for leaks. Refer to owner’s manual for detailed instructions.
OPERATING PRESSURES:
Supply water- 20 psi minimum to 105 psi maximum.
GENERAL
Pedestal, cast iron closed base with forest green enamel finish for year-round beauty with minimum maintenance. Contour-formed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Model 4880FR is 30" high and Model 4881FR is 36" high
FREEZE-RESISTANT VALVE SYSTEM
Freeze-resistant valve designed for ground installation 18" below the frost line. 60" of access tubing provided with the freeze-resistant valve system. The length of the tubing can be adjusted in the field for lesser frost depths.
BUBBLER
Exclusive one-piece, vandal-resistant, chrome plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
WATER INLET
3/8" NPT fitting
DRAIN OUTLET
Drain requirements are detailed in owner’s manual.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front. Shall include contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be single-stream type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

7020 Two Station Drinking Fountain
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing. Wall hanger is included with product. For wall support required locations see installation instructions provided with fountain. Mount wall hanger brackets to the wall per the installation instructions. Hang fountain and attach to wall. Water service line and waste line are to be assembled as required. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.) CAUTION – Fountain must be securely bolted to wall
OPERATING PRESSURES
Supply water-105 psi maximum
NOTE: Trap and service stop not included. A service stop must be installed at the fountain inlet line.
GENERAL
Two-station face-mounted fountain, one-piece non-corrosive stainless steel number 300 series with brushed satin finish. Fountain has stream splitter design basins with perforated grid strainers. Basin shall be 31"W x 14"D x 15"H
BUBBLER
Single-stream angle jet projector. Combination self-closing pushbutton type with integral automatic stream regulator and hood guard.
PUSHBUTTON ACTUATION MECHANISM
Light touch pushbuttons conveniently located on the front of the unit do not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
SUGGESTED SPECIFICATIONS Fountain shall include two contour-formed basins to eliminate splashing and standing water. Projectors shall be single-stream, mound-building type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

7030 Three Station Drinking Fountain
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing. Wall hanger is included with product. For wall support required locations see installation instructions provided with fountain. Mount wall hanger brackets to the wall per the installation instructions. Hang fountain and attach to wall. Water service line and waste line are to be assembled as required. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.) CAUTION – Fountain must be securely bolted to wall
OPERATING PRESSURES
Supply water-105 psi maximum
NOTE: Trap and service stop not included. A service stop must be installed at the fountain inlet line.
GENERAL
Three-station face-mounted fountain, one-piece non-corrosive stainless steel number 300 series with brushed satin finish. Fountain has stream splitter design basins with perforated grid strainers. Basin shall be 31"W x 14"D x 15"H.
BUBBLER
Single-stream angle jet projector. Combination self-closing pushbutton type with integral automatic stream regulator and hood guard.
PUSHBUTTON ACTUATION MECHANISM
Light touch pushbuttons conveniently located on the front of the unit do not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" tube outlet for 1-1/4" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include three contour-formed basins to eliminate splashing and standing water. Projectors shall be single-stream, mound-building type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.

Various Fountains

2501A Bracket Fountain
2501A
• Automatic stream regulator
• Pushbutton, single-stream bubbler
• Chrome-plated exposed fittings
• Removable chrome-plated strainer
• 10" W x 6" D x 3" H satin finish stainless steel basin
• Shipping weight: 5 lbs.
SUGGESTED SPECIFICATIONS
Shall have a basin contour to eliminate splashing and standing water with rounded corners for added safety and ease of maintenance. Shall have removable drain strainer. Projector shall be entirely chrome plated, single stream, push button type with integral hood and stream regulator. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.

4540 Bracket Fountain
4540
• Automatic stream regulator
• Double Bubbler™ projector
• Self-closing lever handle stop
• Chrome-plated exposed fittings
• Removable chrome-plated strainer
• 10" W x 6" D x 3" H satin finish stainless steel basin
• Shipping weight: 8 lbs.
SUGGESTED SPECIFICATIONS
Shall have a basin contour to eliminate splashing and standing water with rounded corners for added safety and ease of maintenance. Shall have removable drain strainer. Projector shall be two-stream mound-building type. Separate self-closing, lever handle valve and adjustable diaphragm-type automatic stream regulator. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.

6000 Countertop Fountain
6000
• Single-stream projector with automatic stream control
• Satin finish stainless steel basin
• All exposed fittings chrome plated
• Removable brass strainer plate
• Union supply connection
• Unit size: 12 1/4" W x 8 1/4" D x 3" H
• Shipping weight: 5 lbs.
SUGGESTED SPECIFICATIONS
Fountain shall have self-rimming stainless steel basin with satin finish. Projector to be pushbutton type with automatic stream control. To have removable drain strainer. Fountain shall have positive shut-off service valve with union supply connection. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.

6028 Countertop Fountain
6028
• Stainless steel with satin finish
• Two-stream, mound-building Double Bubbler™ projector with automatic stream control
• Removable brass strainer plate
• Union supply connection
• Automatic stream regulator
• All exposed fittings chrome plated
• Unit size: 22 1/2" W x 10 1/4" D x 2 7/8" H
• Shipping weight: 10 lbs.
SUGGESTED SPECIFICATIONS
Fountain shall have self-rimming stainless steel basin with satin finish. Underside of basin to be undercoated to prevent condensation and dampen sound. Projector to be two-stream, mound-building type. Shall have self-closing pushbutton valve with diaphragm-type, automatic stream control. Fountain to have removable drain strainer. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.

10000 Countertop Fountain
10000
• Stainless steel with satin finish
• Single-stream projector with automatic stream control
• Removable brass strainer plate
• All exposed fittings chrome plated
• Unit size: 131/4" diameter, 13/4" depth
• Shipping weight: 6 lbs.
SUGGESTED SPECIFICATIONS
Fountain shall have self-rimming stainless steel basin with satin finish. Projector to be pushbutton type with automatic stream control. To have removable drain strainer. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.

2507A Fountain Head
Model 2507A
Two-stream, mound-building projector. Lead-free chrome-plated fittings. Lever handle self-closing stop. Removable shutoff seat. Volume regulator 3" center distance. 1/4" NPT supply. Shipping weight: 3 lbs.

2509 Fountain Head
Model 2509
Two-stream, mound-building projector. Lead-free chrome-plated fittings. Lever handle self-closing stop. Removable chrome-plated shutoff seat. Volume regulator. Hood guard 3/8" NPT supply. Shipping weight: 2 lbs.

3041 Projector
Model 3041
Single-stream angle jet projector, chrome-plated unleaded brass. Combination self-closing pushbutton-type with integral automatic stream regulator. Hood guard 3/8" NPS connection. Use A54881 when ordering. Vandal-Resistant model includes set screw. Use 45660C when ordering. Shipping weight: 2 lbs.