Halsey Taylor Page 5

For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

Credit Card Images

WM8A-Q Wall Mounted Cooler
MOUNTING HEIGHT
Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height.
MOUNTING INSTRUCTIONS
Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6 1/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22 1/2" from floor line for conventional adult installation.
PLUMBING CONNECTIONS
Enter directly into cabinet. Waste 1 1/4" O.D. slip connection. Supply 3/8" tubing. Trap and service stop not included.
OPERATING PRESSURES:
Supply water-105 psi maximum
ELECTRICAL DATA
Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
GENERAL
Self-contained, electric refrigerated, wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

WM8A-Q Series Coolers
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
WM8A-Q 9.6 8.8 8.0 7.2 8 5 69 450


WM8A-WF-Q Wall Mounted Cooler with Filter
MOUNTING HEIGHT
Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height.
MOUNTING INSTRUCTIONS
Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6 1/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22 1/2" from floor line for conventional adult installation.
PLUMBING CONNECTIONS
Enter directly into cabinet. Waste 1 1/4" O.D. slip connection. Supply 3/8" tubing. Trap and service stop not included.
OPERATING PRESSURES:
Supply water-105 psi maximum
ELECTRICAL DATA
Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
GENERAL
Self-contained, electric refrigerated, wallmounted water cooler with lead filter designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
LEAD REDUCTION FILTER
Halsey Taylor Water Cooler With Filter is equipped with the Water Sentry HWF 172 lead reduction system which is designed to remove cysts, such as cryptrosporidium and giardia, lead particles and chlorine. Also reduces odors and discoloration from incoming water. The filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, Particulate, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst. Features include Quick-Disconnect 1/4 turn installation. Has automatic inlet shut-off valve that closes when filter is removed. Filter should be replaced every 1,500 gallons (5678 liters) or approximately one (1) year after installation. Use part number 55897C when ordering replacement filter.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have lead reduction filter and stainless steel basin with removable drain strainer. Bubbler shall be two stream, mound-building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

WM8A-WF-Q Series Coolers
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
WM8A-WF-Q 9.6 8.8 8.0 7.2 8 5 72 450


WM14W-Q Wall Mounted Cooler with Coffee Bar
MOUNTING HEIGHT
Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height.
MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6 1/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22 1/2" from floor line for conventional adult installation.
PLUMBING CONNECTIONS
Enter directly into cabinet. Waste 1 1/4" O.D. slip connection. Supply 3/8" tubing. Trap and service stop not included.
OPERATING PRESSURES:
Supply water-105 psi maximum
ELECTRICAL DATA
Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
GENERAL
Self-contained, electric refrigerated, wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and water cooled copper condenser with maximum heat exchange. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 13.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

WM14W-Q Series Coolers
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
WM14W-Q 13.5 13.5 13.5 13.5 13.5 8 75 920


WM-14ABL-Q Bi-Level Wall Mounted Cooler
MOUNTING HEIGHT
Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height.
MOUNTING INSTRUCTIONS
Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6 1/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22 1/2" from floor line for conventional adult installation.
PLUMBING CONNECTIONS
Enter directly into cabinet. Waste 1 1/4" O.D. slip connection. Supply 3/8" tubing. Trap and service stop not included.
OPERATING PRESSURES:
Supply water-105 psi maximum Minimum 40 psi supply line pressure required in special circumstances when both sides of bilevel are in use simultaneously to ensure adequate stream height. Does not apply to non-refrigerated units.
ELECTRICAL DATA
Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
GENERAL
Self-contained, electric refrigerated, wallmounted bi-level water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 14 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A evaporator/tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

WM14ABL-Q Series Coolers
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
WM14ABL-Q 16.8 15.4 13.5 12.6 13.5 8.0 96 675


SW8A-Q Compact Wall Mounted Cooler
MOUNTING HEIGHT
Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height.
MOUNTING INSTRUCTIONS
Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6 1/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22 1/2" from floor line for conventional adult installation.
PLUMBING CONNECTIONS
Enter directly into cabinet. Waste 1 1/4" O.D. slip connection. Supply 3/8" tubing. Trap and service stop not included.
OPERATING PRESSURES:
Supply water-105 psi maximum
ELECTRICAL
Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
GENERAL
Self-contained, electric refrigerated, wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

SW8A-Q Series Coolers
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
SW8A-Q 9.6 8.8 8.0 7.2 8.0 5.0 68 450


SW8A-VR-Q Vandal Resistant Wall Mounted Cooler
MOUNTING HEIGHT
Mounting height recommended 40" from basin to floor. May be mounted at any desired height.
MOUNTING INSTRUCTIONS
Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 7" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Install 3/8" supply tube to in-line strainer. Secure bottom of cooler to wall using holes provided. Trap and service stop not included.
OPERATING PRESSURES:
Supply water-105 psi maximum
ELECTRICAL DATA
Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
NOTE: A service supply stop must be installed at the cooler inlet line.
GENERAL
Self-contained, electric refrigerated, wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Vandal-resistant projector is one-piece, chrome-plated. Unit has integral hood guard design to prevent contamination from other users, airborne deposits and tampering.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 8 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be vandal-resistant. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

SW8A-VR-Q Series Coolers
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
SW8A-VR-Q 9.6 8.8 8.0 7.2 8.0 5.0 72 450


RC8A-Q Fully Recessed Cooler
INSTALLATION INSTRUCTIONS
Wall-mounting frame must be secured in wall opening with plumbing and electrical supply in place, before installing cooler fountain assembly. Attach fountain to frame, tighten drain plug, and make waste connection. Install cooling unit and make water supply and electrical connections. Open service valve fully and check for water leaks. Adjust automatic stream regulator (on valve body) to provide a drinking stream approximately 11/2" above projector guard. Secure access panel to frame.
MOUNTING HEIGHT
Adult mounting height recommended 40" from basin to floor. May be mounted at any height. To comply with ADA requirements for parallel approach, the floor to bubbler surface height must be adjusted to 36". All other dimensions must be adjusted accordingly.
WALL OPENING
Cut a wall opening 17 1⁄8" W x 481⁄2" H and 161⁄8" above the floor line.
PLUMBING SUPPLY CONNECTIONS
3⁄8" copper tubing to wall box. Connection to the cooling unit requires 3⁄8" tubing connection.
ELECTRICAL SUPPLY CONNECTION
3⁄8" or 1⁄2" (7⁄8" actual) conduit connection to remote chiller. Installation requires trap to be installed in wall. Trap and service stop not included.
OPERATING PRESSURES:
Supply water - 105 psi maximum
GENERAL
Modular, electric refrigerated, fully-recessed wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for side approach. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
FOUNTAIN
One-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish and contour-formed basin.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
MOUNTING FRAME
Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation.
CABINET AND ACCESS PANEL
Cooling unit contained in a heavy gauge galvanized steel cabinet with front and rear panels removable for service. The lower louvered panel is easily removable for access to the chiller unit system.
SUGGESTED SPECIFICATIONS
Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbutton valve on front, contourformed basin to eliminate splashing and standing water. Bubbler shall be chrome plated, two-stream, mound-building type. Cooling unit shall have a high efficiency positive start compressor using R134A with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for side approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

RC Fully Recessed Series Coolers
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
RC8A-Q 9.1 8.3 7.5 6.5 7.5 3.5 89 325


RC8A-Q Fully Recessed Cooler with 14762 Cup Dispenser
GENERAL
Modular, electric refrigerated, fully-recessed wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for side approach. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CUP DISPENSER
Stainless steel with satin finish, fully recessed, single door with two locks, dual cup canister (one reserve). Removable waste bin. Accepts standard 2 3/4" rim dia. cone or paper cups.
FOUNTAIN
One-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish and contour-formed basin.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
MOUNTING FRAME
Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation.
CABINET AND ACCESS PANEL
Cooling unit contained in a heavy gauge galvanized steel cabinet with front and rear panels removable for service. The upper louvered panel is easily removable for access to the chiller unit system.
SUGGESTED SPECIFICATIONS
Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbutton valve on front and contour-formed basin to eliminate splashing and standing water. Bubbler shall be chrome plated, two-stream, mound-building type. Cooling unit shall have a high efficiency positive start compressor using R134A with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for side approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

RC Fully Recessed Series Coolers
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
RC8A-Q w/ 14762 9.1 8.3 7.5 6.5 7.5 3.5 121 325


RC8A-Q Fully Recessed Cooler with 14700 (Cup Dispenser & Glass Filler)
GENERAL
Modular, electric refrigerated, fully-recessed wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for side approach. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CUP DISPENSER
Stainless steel with satin finish, fully recessed, single door with two locks, dual cup canister (one reserve). Removable waste bin. Accepts standard 2 3/4" rim dia. cone or paper cups.
GLASS FILLER
Heavy duty all-brass construction with bright chrome finish. Features adjustable volume regulator and instantaneous shut-off. Translucent blue Lexan push-back arm allows for barrier-free applications. Mating hardware and flex-tubing simplifies hook-up to the mating RCA fountains.
FOUNTAIN
One-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish and contour-formed basin.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
MOUNTING FRAME
Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation.
CABINET AND ACCESS PANEL
Cooling unit contained in a heavy gauge galvanized steel cabinet with front and rear panels removable for service. The upper louvered panel is easily removable for access to the chiller unit system.
SUGGESTED SPECIFICATIONS
Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbutton valve on front and contourformed basin to eliminate splashing and standing water. Bubbler shall be chrome plated, two-stream, mound-building type. Cooling unit shall have a high efficiency positive start compressor using R134A with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for side approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

RC Fully Recessed Series Coolers
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
RC8A-Q w/ 14700 9.1 8.3 7.5 6.5 7.5 3.5 122 325


HBW8A-Q Simulated Recessed Cooler
GENERAL
Self-contained, electric refrigerated, simulatedrecessed wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and water cooled copper/aluminum condenser with maximum heat exchange. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 8 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

HBW8A Simulated Recessed Cooler
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
HBW8A-Q 9.6 8.8 7.5 7.2 7.5 3.5 69 325


SCWT8A-Q Deluxe Free Standing Cooler
ROUGH-IN, MOUNTING, AND ELECTRICAL INSTRUCTIONS
This cooler may be installed against the wall or freestanding from the wall. NOTE: With slight modifications, rough-in
heights from 16.5" and 24.3" can be accommodated. 2" maximum may be cut from the tailpiece provided. For against-the-wall installation Provide 2" x 4" wood blocking back of finished wall for securing cooler flush with finished wall.
(Refer to rough-in drawing.) Install 11/4" trap 5 1/4" from wall face to center of trap inlet. Trap not furnished. Install 3/8" IPS service stop to building supply line. Service stop not furnished. Trap and service stop not included.
OPERATING PRESSURES
Supply water-105 psi maximum
ELECTRICAL
Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Note cord length is 4 feet from cord exit point in cooler. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1 1/4" O.D. slip connection tube from cooler waste to trap is in line. Connect water supply line to 3/8" tubing inlet connection located inside of cabinet below shelf. For freestanding installation A hole is provided in back of cabinet for plumbing entrance. See rough-in drawing and outline drawing. Install 1 1/4" IPS trap inside cabinet. Trap not furnished. Install 3/8" IPS service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to 3/8" tubing inlet connection located inside of cabinet below shelf.
NOTE: Installation outdoors in an unprotected environment is not recommended.
GENERAL
Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

SCWT8A-Q Deluxe Free Standing Cooler
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
SCWT8A-Q 10.3 9.0 8.0 7.2 8.0 5.0 73 450


SCWT8A-WF-Q Deluxe Free Standing Cooler with Filter
ROUGH-IN, MOUNTING, AND ELECTRICAL INSTRUCTIONS
This cooler may be installed against the wall or freestanding from the wall. NOTE: With slight modifications, rough-in heights from 16.5" and 24.3" can be accommodated. 2" maximum may be cut from the tailpiece provided. For against-the-wall installation Provide 2" x 4" wood blocking back of finished wall for securing cooler flush with finished wall. (Refer to rough-in drawing.) Install 11/4" trap 5 1/4" from wall face to center of trap inlet. Trap not furnished. Install 3/8" IPS service stop to building supply line. Trap and service stop not included.
OPERATING PRESSURES:
Supply water-105 psi maximum
ELECTRICAL
Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Note cord length is 4 feet from cord exit point in cooler. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1 1/4" O.D. slip connection tube from cooler waste to trap is in line. Connect water supply line to 3/8" tubing inlet connection located inside of cabinet below shelf. For freestanding installation A hole is provided in back of cabinet for plumbing entrance. See rough-in drawing and outline drawing. Install 1 1/4" IPS trap inside cabinet. Trap not furnished. Install 3/8" IPS service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to 3/8" tubing inlet connection located inside of cabinet below shelf.
NOTE: Installation outdoors in an unprotected environment is not recommended.
GENERAL
Self-contained, electric refrigerated, free-standing water cooler with filter designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
LEAD REDUCTION FILTER
Halsey Taylor Water Cooler With Filter is equipped with the Water Sentry HWF 172 lead reduction system which is designed to remove cysts, such as cryptrosporidium and giardia, lead particles and chlorine. Also reduces odors and discoloration from incoming water. The filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, Particulate, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst. Features include Quick-Disconnect 1/4 turn installation. Has automatic inlet shut-off valve that closes when filter is removed. Filter should be replaced every 1,500 gallons (5678 liters) or approximately one (1) year after installation. Use part number 55897C when ordering replacement filter.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/ storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overloadprotection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have lead reduction filter and stainless steel basin with removable drain strainer. Bubbler shall be twostream, mound- building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

SCWT8A-WF-Q Deluxe Free Standing Cooler with Filter
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
SCWT8A-WF-Q 10.3 9.0 8.0 7.2 8.0 5.0 76 450


SCWT14A-VR-Q Vandal Resistant Free Standing Cooler
ROUGH-IN, MOUNTING, AND ELECTRICAL INSTRUCTIONS
This cooler may be installed against the wall or freestanding from the wall. NOTE: With slight modifications, rough-in heights from 16.5" and 24.3" can be accommodated. 2" maximum may be cut from the tailpiece provided. For against-the-wall installation Provide 2" x 4" wood blocking back of finished wall for securing cooler flush with finished wall. (Refer to rough-in drawing.) Install 11/4" trap 5 1/4" from wall face to center of trap inlet. Trap not furnished. Install 3/8" IPS service stop to building supply line. Trap and service stop not included.
OPERATING PRESSURES:
Supply water-105 psi maximum
ELECTRICAL
Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Note cord length is 4 feet from cord exit point in cooler. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1 1/4" O.D. slip connection tube from cooler waste to trap is in line. Connect water supply line to 3/8" tubing inlet connection located inside of cabinet below shelf. For freestanding installation A hole is provided in back of cabinet for plumbing entrance. See rough-in drawing and outline drawing. Install 1 1/4" IPS trap inside cabinet. Trap not furnished. Install 3/8" IPS service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to 3/8" tubing inlet connection located inside of cabinet below shelf.
GENERAL
Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Vandal-resistant projector is one-piece, chrome-plated. Unit has integral hood guard design to prevent contamination from other users, airborne deposits and tampering.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 13.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be vandal-resistant type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

SCWT14A-VR-Q Free Standing Cooler
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
SCWT14A-VR-Q 18 15.8 13.5 12.6 13.5 8.0 75 625


SCWT8-CB-Q Free Standing Cooler with Coffee Bar
ROUGH-IN, MOUNTING, AND ELECTRICAL INSTRUCTIONS
This cooler may be installed against the wall or freestanding from the wall. NOTE: With slight modifications, rough-in heights from 16.5" and 24.3" can be accommodated. 2" maximum may be cut from the tailpiece provided. For against-the-wall installation Provide 2" x 4" wood blocking back of finished wall for securing cooler flush with finished wall. (Refer to rough-in drawing.) Install 11/4" trap 5 1/4" from wall face to center of trap inlet. Trap not furnished. Install 3/8" IPS service stop to building supply line. Service stop not furnished.
OPERATING PRESSURES:
Supply water-105 psi maximum Trap and service stop not included.
ELECTRICAL
Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Note cord length is 4 feet from cord exit point in cooler. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1 1/4" O.D. slip connection tube from cooler waste to trap is in line. Connect water supply line to 3/8" tubing inlet connection located inside of cabinet below shelf. For freestanding installation A hole is provided in back of cabinet for plumbing entrance. See rough-in drawing and outline drawing. Install 1 1/4" IPS trap inside cabinet. Trap not furnished. Install 3/8" IPS service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to 3/8" tubing inlet connection located inside of cabinet below shelf.
NOTE: Installation outdoors in an unprotected environment is not recommended.
GENERAL
Self-contained, electric refrigerated, freestanding water cooler designed to be easily accessible to able-bodied individuals. Unit meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
HOT WATER HEATER/CUP FILLER
Factory-installed “Coffee-Bar Server” consists of electrically heated hot water tank (capacity 4 pints) and a gooseneck, lever-operated cup filler. Serves 40 six-ounce cups of 165° water per hour.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

SCWT8-CB-Q Free Standing Cooler with Coffee Bar
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
SCWT8-CB-Q 9.7 8.8 8.0 7.2 8.0 10.3 76 1185


SCWT14W-Q Free Standing Water Cooler
ROUGH-IN, MOUNTING, AND ELECTRICAL INSTRUCTIONS
This cooler may be installed against the wall or freestanding from the wall. NOTE: With slight modifications, rough-in heights from 16.5" and 24.3" can be accommodated. 2" maximum may be cut from the tailpiece provided. For against-the-wall installation Provide 2" x 4" wood blocking back of finished wall for securing cooler flush with finished wall. (Refer to rough-in drawing.) Install 11/4" trap 5 1/4" from wall face to center of trap inlet. Trap not furnished. Install 3/8" IPS service stop to building supply line. Service stop not furnished. Trap and service stop not included.
OPERATING PRESSURES:
Supply water-105 psi maximum
ELECTRICAL
Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Note cord length is 4 feet from cord exit point in cooler. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1 1/4" O.D. slip connection tube from cooler waste to trap is in line. Connect water supply line to 3/8" tubing inlet connection located inside of cabinet below shelf. For freestanding installation A hole is provided in back of cabinet for plumbing entrance. See rough-in drawing and outline drawing. Install 1 1/4" IPS trap inside cabinet. Trap not furnished. Install 3/8" IPS service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to 3/8" tubing inlet connection located inside of cabinet below shelf.
NOTE: Installation outdoors in an unprotected environment is not recommended.
GENERAL
Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and water cooled copper condenser with maximum heat exchange. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 13.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

SCWT14W-Q Free Standing Cooler
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
SCWT14W-Q 13.5 13.5 13.5 13.5 13.5 8.0 77 920


XP8W-Q Explosion Proof Free Standing Cooler
GENERAL
Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and water cooled condenser that resists clogging, making unit ideal for high dust areas. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall be floor-standing explosion proof type cooler for extreme conditions, including areas where excessive heat, dust and hazardous atmospheres are present. Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound-building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

XP8W-Q Explosion Proof Free Standing Cooler
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
XP8W-Q 8.0 8.0 8.0 8.0 8.0 5.0 84 400


HOF14A-Q Outdoor Free Standing Cooler
PLUMBING CONNECTIONS
Waste and supply lines through back of cabinet. Waste 11/4" IPS. Supply 3/8" copper. Trap and service stop not included.
OPERATING PRESSURES:
Supply water - 105 psi maximum
ELECTRICAL
Standard 120 volt, 60 Hz, single phase. Requires 1/2" IPS rigid conduit into junction box inside cabinet (hole provided).
GENERAL
Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Vandal-resistant projector is one-piece, chromeplated. Unit has integral hood guard design to prevent contamination from other users, airborne deposits and tampering.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 2 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 13.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be vandal-resistant type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

HOF14A-Q Outdoor Free Standing Cooler
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
HOF14A-Q 14.0 14.0 13.5 14.0 13.5 8.0 90 625


S300-2E-Q Economy Free Standing Cooler
PLUMBING CONNECTIONS
Enter directly into cabinet. Waste 1 1/4". Supply 3/8" tubing. Trap and service stop not included.
OPERATING PRESSURES
Supply water-105 psi maximum
ELECTRICAL
Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Transformers available for other power supplies. (See capacity chart for amp rating.) Install 120-volt receptacle, rated at 15-amp minimum to receive 3-wire parallel blade grounding type male plug.
Note: Installation outdoors in an unprotected environment is not recommended.
GENERAL
Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Unit mounts flush against wall for a cleaner, more attractive appearance. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
PLUMBING CONNECTIONS
Waste and supply lines secured to back of cabinet. Waste 11/4" Supply 3/8" tubing.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F.
STORAGE TANK
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with fixed drain strainer. Bubbler shall be two stream, mound-building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.

S300-2E-Q Economy Free Standing Cooler
Model No. GPH Capacity
Cooled to 50º F
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lbs.
Rated
Watt
Usage
Ambient Air Temp
70º F 80º F 90º F 100º F
S300-2E-Q 3.2 3.0 2.8 2.6 2.8 1.7 54 190

WSP home page Products page Suppliers page  