For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
![]() |
| MOUNTING HEIGHT Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6 1/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22 1/2" from floor line for conventional adult installation. PLUMBING CONNECTIONS Enter directly into cabinet. Waste 1 1/4" O.D. slip connection. Supply 3/8" tubing. Trap and service stop not included. OPERATING PRESSURES: Supply water-105 psi maximum ELECTRICAL DATA Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. |
| GENERAL Self-contained, electric refrigerated, wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| WM8A-Q | 9.6 | 8.8 | 8.0 | 7.2 | 8 | 5 | 69 | 450 |
![]() |
![]() |
| MOUNTING HEIGHT Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6 1/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22 1/2" from floor line for conventional adult installation. PLUMBING CONNECTIONS Enter directly into cabinet. Waste 1 1/4" O.D. slip connection. Supply 3/8" tubing. Trap and service stop not included. OPERATING PRESSURES: Supply water-105 psi maximum ELECTRICAL DATA Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. |
| GENERAL Self-contained, electric refrigerated, wallmounted water cooler with lead filter designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. LEAD REDUCTION FILTER Halsey Taylor Water Cooler With Filter is equipped with the Water Sentry HWF 172 lead reduction system which is designed to remove cysts, such as cryptrosporidium and giardia, lead particles and chlorine. Also reduces odors and discoloration from incoming water. The filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, Particulate, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst. Features include Quick-Disconnect 1/4 turn installation. Has automatic inlet shut-off valve that closes when filter is removed. Filter should be replaced every 1,500 gallons (5678 liters) or approximately one (1) year after installation. Use part number 55897C when ordering replacement filter. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have lead reduction filter and stainless steel basin with removable drain strainer. Bubbler shall be two stream, mound-building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| WM8A-WF-Q | 9.6 | 8.8 | 8.0 | 7.2 | 8 | 5 | 72 | 450 |
![]() |
![]() |
| MOUNTING HEIGHT Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6 1/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22 1/2" from floor line for conventional adult installation. PLUMBING CONNECTIONS Enter directly into cabinet. Waste 1 1/4" O.D. slip connection. Supply 3/8" tubing. Trap and service stop not included. OPERATING PRESSURES: Supply water-105 psi maximum ELECTRICAL DATA Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. |
| GENERAL Self-contained, electric refrigerated, wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and water cooled copper condenser with maximum heat exchange. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 13.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| WM14W-Q | 13.5 | 13.5 | 13.5 | 13.5 | 13.5 | 8 | 75 | 920 |
![]() |
![]() |
| MOUNTING HEIGHT Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6 1/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22 1/2" from floor line for conventional adult installation. PLUMBING CONNECTIONS Enter directly into cabinet. Waste 1 1/4" O.D. slip connection. Supply 3/8" tubing. Trap and service stop not included. OPERATING PRESSURES: Supply water-105 psi maximum Minimum 40 psi supply line pressure required in special circumstances when both sides of bilevel are in use simultaneously to ensure adequate stream height. Does not apply to non-refrigerated units. ELECTRICAL DATA Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. |
| GENERAL Self-contained, electric refrigerated, wallmounted bi-level water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 14 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A evaporator/tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| WM14ABL-Q | 16.8 | 15.4 | 13.5 | 12.6 | 13.5 | 8.0 | 96 | 675 |
![]() |
![]() |
| MOUNTING HEIGHT Adult mounting height recommended 40" from basin to floor. May be mounted at any desired height. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 6 1/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet is 22 1/2" from floor line for conventional adult installation. PLUMBING CONNECTIONS Enter directly into cabinet. Waste 1 1/4" O.D. slip connection. Supply 3/8" tubing. Trap and service stop not included. OPERATING PRESSURES: Supply water-105 psi maximum ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. |
| GENERAL Self-contained, electric refrigerated, wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| SW8A-Q | 9.6 | 8.8 | 8.0 | 7.2 | 8.0 | 5.0 | 68 | 450 |
![]() |
![]() |
| MOUNTING HEIGHT Mounting height recommended 40" from basin to floor. May be mounted at any desired height. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 7" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Install 3/8" supply tube to in-line strainer. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water-105 psi maximum ELECTRICAL DATA Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. NOTE: A service supply stop must be installed at the cooler inlet line. |
| GENERAL Self-contained, electric refrigerated, wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Vandal-resistant projector is one-piece, chrome-plated. Unit has integral hood guard design to prevent contamination from other users, airborne deposits and tampering. PUSHBUTTON ACTUATION MECHANISM Self closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 8 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be vandal-resistant. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| SW8A-VR-Q | 9.6 | 8.8 | 8.0 | 7.2 | 8.0 | 5.0 | 72 | 450 |
![]() |
![]() |
| INSTALLATION INSTRUCTIONS Wall-mounting frame must be secured in wall opening with plumbing and electrical supply in place, before installing cooler fountain assembly. Attach fountain to frame, tighten drain plug, and make waste connection. Install cooling unit and make water supply and electrical connections. Open service valve fully and check for water leaks. Adjust automatic stream regulator (on valve body) to provide a drinking stream approximately 11/2" above projector guard. Secure access panel to frame. MOUNTING HEIGHT Adult mounting height recommended 40" from basin to floor. May be mounted at any height. To comply with ADA requirements for parallel approach, the floor to bubbler surface height must be adjusted to 36". All other dimensions must be adjusted accordingly. WALL OPENING Cut a wall opening 17 1⁄8" W x 481⁄2" H and 161⁄8" above the floor line. PLUMBING SUPPLY CONNECTIONS 3⁄8" copper tubing to wall box. Connection to the cooling unit requires 3⁄8" tubing connection. ELECTRICAL SUPPLY CONNECTION 3⁄8" or 1⁄2" (7⁄8" actual) conduit connection to remote chiller. Installation requires trap to be installed in wall. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum |
| GENERAL Modular, electric refrigerated, fully-recessed wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for side approach. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN One-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish and contour-formed basin. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. CABINET AND ACCESS PANEL Cooling unit contained in a heavy gauge galvanized steel cabinet with front and rear panels removable for service. The lower louvered panel is easily removable for access to the chiller unit system. SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbutton valve on front, contourformed basin to eliminate splashing and standing water. Bubbler shall be chrome plated, two-stream, mound-building type. Cooling unit shall have a high efficiency positive start compressor using R134A with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for side approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| RC8A-Q | 9.1 | 8.3 | 7.5 | 6.5 | 7.5 | 3.5 | 89 | 325 |
![]() |
![]() |
| GENERAL Modular, electric refrigerated, fully-recessed wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for side approach. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CUP DISPENSER Stainless steel with satin finish, fully recessed, single door with two locks, dual cup canister (one reserve). Removable waste bin. Accepts standard 2 3/4" rim dia. cone or paper cups. FOUNTAIN One-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish and contour-formed basin. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self closing, vandal-resistant pushbutton does not require grasping or twisting. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. CABINET AND ACCESS PANEL Cooling unit contained in a heavy gauge galvanized steel cabinet with front and rear panels removable for service. The upper louvered panel is easily removable for access to the chiller unit system. SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbutton valve on front and contour-formed basin to eliminate splashing and standing water. Bubbler shall be chrome plated, two-stream, mound-building type. Cooling unit shall have a high efficiency positive start compressor using R134A with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for side approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| RC8A-Q w/ 14762 | 9.1 | 8.3 | 7.5 | 6.5 | 7.5 | 3.5 | 121 | 325 |
![]() |
![]() |
| GENERAL Modular, electric refrigerated, fully-recessed wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for side approach. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CUP DISPENSER Stainless steel with satin finish, fully recessed, single door with two locks, dual cup canister (one reserve). Removable waste bin. Accepts standard 2 3/4" rim dia. cone or paper cups. GLASS FILLER Heavy duty all-brass construction with bright chrome finish. Features adjustable volume regulator and instantaneous shut-off. Translucent blue Lexan push-back arm allows for barrier-free applications. Mating hardware and flex-tubing simplifies hook-up to the mating RCA fountains. FOUNTAIN One-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish and contour-formed basin. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. CABINET AND ACCESS PANEL Cooling unit contained in a heavy gauge galvanized steel cabinet with front and rear panels removable for service. The upper louvered panel is easily removable for access to the chiller unit system. SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbutton valve on front and contourformed basin to eliminate splashing and standing water. Bubbler shall be chrome plated, two-stream, mound-building type. Cooling unit shall have a high efficiency positive start compressor using R134A with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for side approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| RC8A-Q w/ 14700 | 9.1 | 8.3 | 7.5 | 6.5 | 7.5 | 3.5 | 122 | 325 |
![]() |
![]() |
| GENERAL Self-contained, electric refrigerated, simulatedrecessed wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and water cooled copper/aluminum condenser with maximum heat exchange. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 8 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HBW8A-Q | 9.6 | 8.8 | 7.5 | 7.2 | 7.5 | 3.5 | 69 | 325 |
![]() |
![]() |
| ROUGH-IN, MOUNTING, AND ELECTRICAL INSTRUCTIONS This cooler may be installed against the wall or freestanding from the wall. NOTE: With slight modifications, rough-in heights from 16.5" and 24.3" can be accommodated. 2" maximum may be cut from the tailpiece provided. For against-the-wall installation Provide 2" x 4" wood blocking back of finished wall for securing cooler flush with finished wall. (Refer to rough-in drawing.) Install 11/4" trap 5 1/4" from wall face to center of trap inlet. Trap not furnished. Install 3/8" IPS service stop to building supply line. Service stop not furnished. Trap and service stop not included. OPERATING PRESSURES Supply water-105 psi maximum ELECTRICAL Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Note cord length is 4 feet from cord exit point in cooler. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1 1/4" O.D. slip connection tube from cooler waste to trap is in line. Connect water supply line to 3/8" tubing inlet connection located inside of cabinet below shelf. For freestanding installation A hole is provided in back of cabinet for plumbing entrance. See rough-in drawing and outline drawing. Install 1 1/4" IPS trap inside cabinet. Trap not furnished. Install 3/8" IPS service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to 3/8" tubing inlet connection located inside of cabinet below shelf. NOTE: Installation outdoors in an unprotected environment is not recommended. |
| GENERAL Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| SCWT8A-Q | 10.3 | 9.0 | 8.0 | 7.2 | 8.0 | 5.0 | 73 | 450 |
![]() |
![]() |
| ROUGH-IN, MOUNTING, AND ELECTRICAL INSTRUCTIONS This cooler may be installed against the wall or freestanding from the wall. NOTE: With slight modifications, rough-in heights from 16.5" and 24.3" can be accommodated. 2" maximum may be cut from the tailpiece provided. For against-the-wall installation Provide 2" x 4" wood blocking back of finished wall for securing cooler flush with finished wall. (Refer to rough-in drawing.) Install 11/4" trap 5 1/4" from wall face to center of trap inlet. Trap not furnished. Install 3/8" IPS service stop to building supply line. Trap and service stop not included. OPERATING PRESSURES: Supply water-105 psi maximum ELECTRICAL Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Note cord length is 4 feet from cord exit point in cooler. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1 1/4" O.D. slip connection tube from cooler waste to trap is in line. Connect water supply line to 3/8" tubing inlet connection located inside of cabinet below shelf. For freestanding installation A hole is provided in back of cabinet for plumbing entrance. See rough-in drawing and outline drawing. Install 1 1/4" IPS trap inside cabinet. Trap not furnished. Install 3/8" IPS service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to 3/8" tubing inlet connection located inside of cabinet below shelf. NOTE: Installation outdoors in an unprotected environment is not recommended. |
| GENERAL Self-contained, electric refrigerated, free-standing water cooler with filter designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. LEAD REDUCTION FILTER Halsey Taylor Water Cooler With Filter is equipped with the Water Sentry HWF 172 lead reduction system which is designed to remove cysts, such as cryptrosporidium and giardia, lead particles and chlorine. Also reduces odors and discoloration from incoming water. The filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, Particulate, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst. Features include Quick-Disconnect 1/4 turn installation. Has automatic inlet shut-off valve that closes when filter is removed. Filter should be replaced every 1,500 gallons (5678 liters) or approximately one (1) year after installation. Use part number 55897C when ordering replacement filter. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/ storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overloadprotection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have lead reduction filter and stainless steel basin with removable drain strainer. Bubbler shall be twostream, mound- building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| SCWT8A-WF-Q | 10.3 | 9.0 | 8.0 | 7.2 | 8.0 | 5.0 | 76 | 450 |
![]() |
![]() |
| ROUGH-IN, MOUNTING, AND ELECTRICAL INSTRUCTIONS This cooler may be installed against the wall or freestanding from the wall. NOTE: With slight modifications, rough-in heights from 16.5" and 24.3" can be accommodated. 2" maximum may be cut from the tailpiece provided. For against-the-wall installation Provide 2" x 4" wood blocking back of finished wall for securing cooler flush with finished wall. (Refer to rough-in drawing.) Install 11/4" trap 5 1/4" from wall face to center of trap inlet. Trap not furnished. Install 3/8" IPS service stop to building supply line. Trap and service stop not included. OPERATING PRESSURES: Supply water-105 psi maximum ELECTRICAL Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Note cord length is 4 feet from cord exit point in cooler. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1 1/4" O.D. slip connection tube from cooler waste to trap is in line. Connect water supply line to 3/8" tubing inlet connection located inside of cabinet below shelf. For freestanding installation A hole is provided in back of cabinet for plumbing entrance. See rough-in drawing and outline drawing. Install 1 1/4" IPS trap inside cabinet. Trap not furnished. Install 3/8" IPS service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to 3/8" tubing inlet connection located inside of cabinet below shelf. |
| GENERAL Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Vandal-resistant projector is one-piece, chrome-plated. Unit has integral hood guard design to prevent contamination from other users, airborne deposits and tampering. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 13.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be vandal-resistant type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| SCWT14A-VR-Q | 18 | 15.8 | 13.5 | 12.6 | 13.5 | 8.0 | 75 | 625 |
![]() |
![]() |
| ROUGH-IN, MOUNTING, AND ELECTRICAL INSTRUCTIONS This cooler may be installed against the wall or freestanding from the wall. NOTE: With slight modifications, rough-in heights from 16.5" and 24.3" can be accommodated. 2" maximum may be cut from the tailpiece provided. For against-the-wall installation Provide 2" x 4" wood blocking back of finished wall for securing cooler flush with finished wall. (Refer to rough-in drawing.) Install 11/4" trap 5 1/4" from wall face to center of trap inlet. Trap not furnished. Install 3/8" IPS service stop to building supply line. Service stop not furnished. OPERATING PRESSURES: Supply water-105 psi maximum Trap and service stop not included. ELECTRICAL Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Note cord length is 4 feet from cord exit point in cooler. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1 1/4" O.D. slip connection tube from cooler waste to trap is in line. Connect water supply line to 3/8" tubing inlet connection located inside of cabinet below shelf. For freestanding installation A hole is provided in back of cabinet for plumbing entrance. See rough-in drawing and outline drawing. Install 1 1/4" IPS trap inside cabinet. Trap not furnished. Install 3/8" IPS service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to 3/8" tubing inlet connection located inside of cabinet below shelf. NOTE: Installation outdoors in an unprotected environment is not recommended. |
| GENERAL Self-contained, electric refrigerated, freestanding water cooler designed to be easily accessible to able-bodied individuals. Unit meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. HOT WATER HEATER/CUP FILLER Factory-installed “Coffee-Bar Server” consists of electrically heated hot water tank (capacity 4 pints) and a gooseneck, lever-operated cup filler. Serves 40 six-ounce cups of 165° water per hour. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| SCWT8-CB-Q | 9.7 | 8.8 | 8.0 | 7.2 | 8.0 | 10.3 | 76 | 1185 |
![]() |
![]() |
| ROUGH-IN, MOUNTING, AND ELECTRICAL INSTRUCTIONS This cooler may be installed against the wall or freestanding from the wall. NOTE: With slight modifications, rough-in heights from 16.5" and 24.3" can be accommodated. 2" maximum may be cut from the tailpiece provided. For against-the-wall installation Provide 2" x 4" wood blocking back of finished wall for securing cooler flush with finished wall. (Refer to rough-in drawing.) Install 11/4" trap 5 1/4" from wall face to center of trap inlet. Trap not furnished. Install 3/8" IPS service stop to building supply line. Service stop not furnished. Trap and service stop not included. OPERATING PRESSURES: Supply water-105 psi maximum ELECTRICAL Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Note cord length is 4 feet from cord exit point in cooler. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1 1/4" O.D. slip connection tube from cooler waste to trap is in line. Connect water supply line to 3/8" tubing inlet connection located inside of cabinet below shelf. For freestanding installation A hole is provided in back of cabinet for plumbing entrance. See rough-in drawing and outline drawing. Install 1 1/4" IPS trap inside cabinet. Trap not furnished. Install 3/8" IPS service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to 3/8" tubing inlet connection located inside of cabinet below shelf. NOTE: Installation outdoors in an unprotected environment is not recommended. |
| GENERAL Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and water cooled copper condenser with maximum heat exchange. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 13.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, moundbuilding type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| SCWT14W-Q | 13.5 | 13.5 | 13.5 | 13.5 | 13.5 | 8.0 | 77 | 920 |
![]() |
![]() |
| GENERAL Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and water cooled condenser that resists clogging, making unit ideal for high dust areas. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall be floor-standing explosion proof type cooler for extreme conditions, including areas where excessive heat, dust and hazardous atmospheres are present. Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound-building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| XP8W-Q | 8.0 | 8.0 | 8.0 | 8.0 | 8.0 | 5.0 | 84 | 400 |
![]() |
![]() |
| PLUMBING CONNECTIONS Waste and supply lines through back of cabinet. Waste 11/4" IPS. Supply 3/8" copper. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum ELECTRICAL Standard 120 volt, 60 Hz, single phase. Requires 1/2" IPS rigid conduit into junction box inside cabinet (hole provided). |
| GENERAL Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Vandal-resistant projector is one-piece, chromeplated. Unit has integral hood guard design to prevent contamination from other users, airborne deposits and tampering. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 2 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 13.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be vandal-resistant type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HOF14A-Q | 14.0 | 14.0 | 13.5 | 14.0 | 13.5 | 8.0 | 90 | 625 |
![]() |
![]() |
| PLUMBING CONNECTIONS Enter directly into cabinet. Waste 1 1/4". Supply 3/8" tubing. Trap and service stop not included. OPERATING PRESSURES Supply water-105 psi maximum ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Transformers available for other power supplies. (See capacity chart for amp rating.) Install 120-volt receptacle, rated at 15-amp minimum to receive 3-wire parallel blade grounding type male plug. Note: Installation outdoors in an unprotected environment is not recommended. |
| GENERAL Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Unit mounts flush against wall for a cleaner, more attractive appearance. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. PLUMBING CONNECTIONS Waste and supply lines secured to back of cabinet. Waste 11/4" Supply 3/8" tubing. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver ( ) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with fixed drain strainer. Bubbler shall be two stream, mound-building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| S300-2E-Q | 3.2 | 3.0 | 2.8 | 2.6 | 2.8 | 1.7 | 54 | 190 |
| WSP home page | Products page | Suppliers page | |
| Fountains & Coolers | Halsey Taylor Index | Previous Halsey Taylor Page | Next Halsey Taylor Page |