For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
![]() |
| GENERAL Self-contained, electric refrigerated wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSH BAR ACTUATION MECHANISM Self-closing light-touch push bars with raised letters for the visually impaired. F models have front pushbars only. FS models have pushbars on front and sides. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have front (or front and side) push-bar water controls with raised lettering for the visually impaired. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| WC8AFS-Q | 9.6 | 8.8 | 8.0 | 7.2 | 8.0 | 3.7 | 100 | 325 |
![]() |
![]() |
| WALL OPENING IMPORTANT: It is necessary to create a wall opening 18 3/4" W x 37 3/4" H and 41/2" above the floor line. MOUNTING INSTRUCTIONS Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper fountain panel to hanger on frame. Fountains are to be attached to panel and wall frame. Water service lines, waste lines and electrical are assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.) Installation requires trap to be installed in wall. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum ELECTRICAL DATA Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase. |
| GENERAL Modular, electric refrigerated, wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN Oval shape fountain, non-corrosive stainless steel, with brushed satin finish. Contour-formed basin with rounded corners and edges. Oval fountain shape requires less neck extension and bending for the wheel chair user. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. PUSH BAR ACTUATION MECHANISM Self-closing, semi-circular push bar can be actuated at any point on its 180° radius. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. PANELS Constructed of stainless steel, number 300 series with satin finish. Removable lower panel provides access to plumbing and refrigeration system. Panels overlap wall opening 1/2˝. SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbar valve on front, contour-formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, two-stream, mound building type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| OVL-II ER-Q | 9.3 | 8.3 | 7.5 | 6.8 | 7.5 | 3.5 | 96 | 325 |
![]() |
![]() |
| WALL OPENING IMPORTANT: It is necessary to create a wall opening 18 3/4˝ W x 37 3/4˝ H and 41/2˝ above the floor line. MOUNTING INSTRUCTIONS Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper fountain panel to hanger on frame. Fountain to be attached to panel and wall frame. Water service lines, waste lines and electrical are assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.) Installation requires trap to be installed in wall. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum ELECTRICAL DATA Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase. |
| GENERAL Modular, electric refrigerated, wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN Oval shape fountain, non-corrosive stainless steel, with brushed satin finish. Contour-formed basin with rounded corners and edges. Oval fountain shape requires less neck extension and bending for the wheel chair user. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. AUTOMATIC ACTUATION Model OVL-IIEREE-Q features infra-red light beam emitting sensor and a solenoid valve. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. Supplied with a built-in time delay to avoid nuisance actuation from passers-by. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. PANELS Constructed of stainless steel, number 300 series with satin finish. Removable lower panel provides access to plumbing and refrigeration system. Panels overlap wall opening 1/2˝. SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include infra-red sensor, contour-formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, two-stream, mound- building type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| OVL-II EREE-Q | 9.3 | 8.3 | 7.5 | 6.8 | 7.5 | 3.5 | 101 | 325 |
![]() |
![]() |
| WALL OPENING IMPORTANT: It is necessary to create a wall opening 37 1/2˝ W x 37 3/4˝ H and 41/2˝ above the floor line. MOUNTING INSTRUCTIONS Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper panel to hanger on frame. Fountains are to be attached to panel and wall frame. Water service lines, waste lines and electrical are assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.) Installation requires trap to be installed in wall. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances where both sides of bilevel are in use simultaneously to ensure adequate stream height. Use of water filter in this situation is not recommended. ELECTRICAL DATA Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase. |
| GENERAL Modular, electric refrigerated, bi-level wall-mounted water cooler designed to be easily accessible to physically challenged and able-bodied individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN Oval shape fountain, non-corrosive stainless steel, with brushed satin finish. Contour-formed basin with rounded corners and edges. Oval fountain shape requires less neck extension and bending for the wheel chair user. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. PUSHBAR ACTUATION MECHANISM Self-closing, semi-circular push bar can be actuated at any point on its 180° radius. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. PANELS Constructed of stainless steel number 300 series with satin finish. Removable lower panel provides access to plumbing and refrigeration system. Panels overlap wall opening 1/2˝. SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbar valve on front, contour-formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, two-stream, moundbuilding type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| OVL-II SER-Q | 9.3 | 8.3 | 7.5 | 6.8 | 7.5 | 3.5 | 135 | 325 |
![]() |
![]() |
| WALL OPENING IMPORTANT: It is necessary to create a wall opening 37 1/2" W x 37 3/4" H and 41/2" above the floor line. MOUNTING INSTRUCTIONS Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper panel to hanger on frame. Fountains are to be attached to panel and wall frame. Water service lines, waste lines, and electrical are assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.) Installation requires trap to be installed in wall. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances where both sides of bilevel are in use simultaneously to ensure adequate stream height. Use of water filter in this situation is not recommended. ELECTRICAL DATA Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase. |
| GENERAL Modular, electric refrigerated, bi-level wall-mounted water cooler designed to be easily accessible to physically challenged and able-bodied individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN Oval shape fountain, non-corrosive stainless steel, with brushed satin finish. Contour-formed basin with rounded corners and edges. Oval fountain shape requires less neck extension and bending for the wheel chair user. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. AUTOMATIC ACTUATION Model OVL-IISEREE-Q features infra-red light beam emitting sensor and a solenoid valve on the extended right receptor. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. Supplied with a built-in time delay to avoid nuisance actuation from passers-by. On the left side, the self-closing, semi-circular push bar can be actuated at any point on its 180° radius. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. PANELS Constructed of stainless steel, number 300 series with satin finish. Removable lower panel provides access to plumbing and refrigeration system. Panels overlap wall opening 1/2˝. SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include infra-red sensor, contour-formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, two-stream, mound- building type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| OVL-II SEREE-Q | 9.3 | 8.3 | 7.5 | 6.8 | 7.5 | 3.5 | 140 | 325 |
![]() |
![]() |
| WALL OPENING IMPORTANT: It is necessary to create a wall opening 18 3/4" W x 37 3/4" H and 41/2" above the floor line. MOUNTING INSTRUCTIONS Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper fountain panel to hanger on frame. Fountain is to be attached to panel and wall frame. Water service line, waste line and electrical is assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.) Installation requires trap to be installed in wall. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum ELECTRICAL DATA Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase. |
| GENERAL Modular, electric refrigerated, wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children and adults. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN Face-mounted, one-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish, contour-formed basin with softly rounded corners and edges. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. PANELS Constructed of stainless steel, No. 300 series with satin finish. Removable lower panel provides access to plumbing and refrigeration system. Panels overlap wall opening 1/2˝. SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbutton valve on front, contour formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, twostream, mound- building type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HCRFER-Q | 9.3 | 8.3 | 7.5 | 6.8 | 7.5 | 4.5 | 84 | 325 |
![]() |
![]() |
| WALL OPENING IMPORTANT: It is necessary to create a wall opening 18 3/4" W x 37 3/4" H and 41/2" above the floor line. MOUNTING INSTRUCTIONS Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper fountain panel to hanger on frame. Fountain is to be attached to panel and wall frame. Water service line, waste line and electrical is assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.) OPERATING PRESSURES: Supply water - 105 psi maximum ELECTRICAL DATA Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase. |
| GENERAL Modular, electric refrigerated, wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to ANSI/NSF 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN Face-mounted, one-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish, contour-formed basin with softly rounded corners and edges. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. PANELS Constructed of stainless steel, number 300 series with satin finish. Removable lower panel provides access to plumbing and refrigeration system. Panels overlap wall opening 1/2˝. SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbutton valve on front, contour formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, twostream, mound- building type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilites. The manufacturer shall certify the unit to meet the requirements of ANSI/NSF 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HRFER-Q | 9.3 | 8.3 | 7.5 | 6.8 | 7.5 | 3.5 | 83 | 325 |
![]() |
![]() |
| WALL OPENING IMPORTANT: It is necessary to create a wall opening 18 3/4" W x 37 3/4" H and 41/2" above the floor line. MOUNTING INSTRUCTIONS Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper fountain panel to hanger on frame. Fountain is to be attached to panel and wall frame. Water service line, waste line and electrical is assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.) OPERATING PRESSURES: Supply water - 105 psi maximum ELECTRICAL DATA Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase. |
| GENERAL Modular, electric refrigerated, wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN Face-mounted, one-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish, contour-formed basin with softly rounded corners. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. AUTOMATIC ACTUATION Model HRFEREE-Q features infra-red light beam emitting sensor and a solenoid valve. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. Supplied with a built-in time delay to avoid nuisance actuation from passers-by. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. PANELS Constructed of stainless steel, number 300 series with satin finish. Removable lower panel provides access to plumbing and refrigeration system. Panels overlap wall opening 1/2". SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include infra-red sensor, contour-formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, two-stream, mound- building type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HRFEREE-Q | 9.3 | 8.3 | 7.5 | 6.8 | 7.5 | 3.5 | 96 | 325 |
![]() |
![]() |
| WALL OPENING IMPORTANT: It is necessary to create a wall opening 37 1/2" W x 37 3/4" H and 41/2" above the floor line. MOUNTING INSTRUCTIONS Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper fountain panel to hanger on frame. Fountain is to be attached to panel and wall frame. Water service lines, waste lines and electrical are assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.) OPERATING PRESSURES: Supply water - 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances where both sides of bilevel are in use simultaneously to ensure adequate stream height. Use of water filter in this situation is not recommended. ELECTRICAL DATA Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase. |
| GENERAL Modular, electric refrigerated, bi-level wall-mounted water cooler designed to be easily accessible to physically challenged and able-bodied individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN Face-mounted, one-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish, contour-formed basin with softly rounded corners. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. PANELS Constructed of stainless steel, number 300 series with satin finish. Removable lower panel providing access to plumbing and refrigeration system. Panels overlap wall opening 1/2˝. SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbutton valve on front, contour formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, twostream, mound- building type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HRFSER-Q | 9.3 | 8.3 | 7.5 | 6.8 | 7.5 | 3.5 | 130 | 325 |
![]() |
![]() |
| WALL OPENING IMPORTANT: It is necessary to create a wall opening 37 1/2" W x 37 3/4" H and 41/2" above the floor line. MOUNTING INSTRUCTIONS Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper fountain panel to hanger on frame. Fountain is to be attached to panel and wall frame. Water service lines, waste lines and electrical are assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.) OPERATING PRESSURES: Supply water - 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances where both sides of bilevel are in use simultaneously to ensure adequate stream height. Use of water filter in this situation is not recommended. ELECTRICAL DATA Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase. |
| GENERAL Modular, electric refrigerated, bi-level wallmounted water cooler designed to be easily accessible to physically challenged and able bodied individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN Face-mounted, one-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish and contour-formed basin. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. AUTOMATIC ACTUATION Model HRFSEREE-Q features infra-red light beam emitting sensor and a solenoid valve on the extended right receptor. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. Supplied with a built-in time delay to avoid nuisance actuation from passers-by. The left side features a pushbutton valve with automatic stream regulator. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. PANELS Constructed of stainless steel, number 300 series with satin finish. Removable lower panel providing access to plumbing and refrigeration system. Panels overlap wall opening 1/2". SUGGESTED SPECIFICATIONS Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include infra-red sensor, contour-formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, two-stream, mound- building type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HRFSEREE-Q | 9.3 | 8.3 | 7.5 | 6.8 | 7.5 | 3.5 | 135 | 325 |
![]() |
![]() |
| WALL OPENING Cut a wall opening 17 1/8" W x 52 1/4" H at 30" above the floor line for fountain and cooling unit. Cut a wall opening 30" W x 27" H and 20" D for wheelchair access area. This opening must be centered under the fountain. Reinforce the wall opening on all sides so that it will adequately support the water cooler. IT MUST SUPPORT UP TO 150 LBS. and provide a means of securing the frame assembly in place. MOUNTING INSTRUCTIONS AND PLUMBING CONNECTIONS Install the shelf into the upper frame area and secure with the 5/16" x 3/4" fasteners supplied. Attach the frame assembly squarely into the building wall, shim if necessary. Be sure panel fasteners are facing the front. Install drain on building waste as shown in drawings. Hang fountain so that it engages to hanger. Secure the bottom with brackets and wing nuts provided. Connect drain assembly to fountain. Slide cooling unit on to shelf and make plumbing connections. Open service valve and check for leaks. Line up panel and grill and fasten. Installation requires trap to be installed in wall. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum ELECTRICAL DATA Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase. |
| GENERAL Modular, electric refrigerated, fully-recessed wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. FOUNTAIN One-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish and contour-formed basin. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. PUSHBUTTON ACTUATION MECHANISM Self closing, vandal-resistant pushbutton does not require grasping or twisting. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. MOUNTING FRAME Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation. CABINET AND ACCESS PANEL Cooling unit contained in a heavy gauge galvanized steel cabinet with front and rear panels removable for service. The upper louvered panel is easily removable for access to the chiller unit system. SUGGESTED SPECIFICATIONS Shall deliver 8 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbutton valve on front, contourformed basin to eliminate splashing and standing water. Bubbler shall be chrome plated, two-stream, mound-building type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| BFMR-Q | 9.3 | 8.3 | 7.5 | 6.8 | 7.5 | 3.5 | 91 | 325 |
| WSP home page | Products page | Suppliers page | |
| Fountains & Coolers | Halsey Taylor Index | Previous Halsey Taylor Page | Next Halsey Taylor Page |