For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
![]() Front View |
![]() Side View |
| GENERAL Self-contained, electric refrigerated wall-mounted water cooler with softly rounded corners and edges, designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children and adults. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Molded two-tone gray space-age polymer with softly rounded edges. Resistant to impact, wear, corrosion, heat and sunlight. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash design reduces splatter. Contour design and integral strainer insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSH BAR ACTUATION MECHANISM Self-closing light-touch push bars require minimal pressure to activate. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. SOLENOID VALVE / INLET STRAINER Self-closing solenoid valve includes easily cleaned in-line strainer that screens particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver (7.6) GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with integral drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have push-bar water controls. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Water will not flow from bubbler unless unit is connected to electricity. |
| MOUNTING HEIGHT Mounting height recommended 30 1/4" from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall with six fasteners. To insure proper engaging of waste line into trap, centerline of trap must be 7" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Connect service stop to solenoid valve using 3/8" supply tube. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water - 20 to 105 psi ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. Legend: A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN C = 1-1/4” TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F = 5/16" BOLT HOLES FOR FASTENING UNIT TO WALL |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HTV4-Q | 5.0 | 4.4 | 4.0 | 3.5 | 4.0 | 4.5 | 51 | 360 |
| HTV8-Q | 9.6 | 8.8 | 7.6 | 7.2 | 7.6 | 4.5 | 51 | 360 |
![]() |
![]() Front View |
![]() Side View |
| MOUNTING HEIGHT Mounting height recommended 30 1/4˝ from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall with six fasteners. To insure proper engaging of waste line into trap, centerline of trap must be 7˝ from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Connect service stop to solenoid valve using 3/8˝ supply tube. Secure bottom of cooler to wall using holes provided. Trap and service stop not included OPERATING PRESSURES: Supply water - 20 to 105 psi ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. Legend: A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE(NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN C = 1-1/4” TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F = 5/16" BOLT HOLES FOR FASTENING UNIT TO WALL When replacing a model ‘HAC’ with a new unit ‘HTV’, installer must cut 1-7/8" from length of cooler waste line before connecing to trap. |
| GENERAL Self-contained, electric refrigerated wall-mounted water cooler with softly rounded corners and edges, designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children and adults. Unit is certified to NSF/ANSI 61, and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. LEAD REDUCTION FILTER Halsey Taylor Water Cooler With Filter is equipped with the Aqua Sentry HWF142 lead reduction system which is designed to remove cysts, such as cryptrosporidium and giardia, lead particles and chlorine taste and odor. The filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst. Features include Quick-Disconnect fittings on each end of the in-line filter. The filter contains a carbon block with lead sorbent media and the housing is made of rust and corrosion free plastic. Filter should be replaced every 750 gallons (2839 liters) or approximately 6 months after installation. Use part number 56191C when ordering replacement filter. CABINET Molded two-tone gray space-age polymer with softly rounded edges. Resistant to impact, wear, corrosion, heat and sunlight. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash design reduces splatter. Contour design and integral strainer insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSH BAR ACTUATION MECHANISM Self-closing light-touch push bars require minimal pressure to activate. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. SOLENOID VALVE / INLET STRAINER Self-closing solenoid valve includes easily cleaned in-line strainer that screens particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 7.6 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with integral drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have push-bar water controls. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. NOTE: Water will not flow from bubbler unless unit is connected to electricity. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HTV8-WF-Q | 9.6 | 8.8 | 7.6 | 7.2 | 7.6 | 4.5 | 53 | 360 |
![]() |
![]() Front View |
![]() Side View |
| GENERAL Self-contained, electric refrigerated wall-mounted water cooler with softly rounded corners and edges, designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children and adults. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Molded two-tone gray space-age polymer with softly rounded edges. Resistant to impact, wear, corrosion, heat and sunlight. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash design reduces splatter. Contour design and integral strainer insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC ACTUATION Model HTV8EE-Q features infra-red light beam emitting sensor and a solenoid valve. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. The water flow is automatically shut-off after 30 seconds or earlier if the user leaves the sensing range. Supplied with a built-in time delay to avoid nuisance actuation from passers-by. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. SOLENOID VALVE / INLET STRAINER Self-closing solenoid valve includes easily cleaned in-line strainer that screens particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 7.6 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with integral drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have electronic eye water control for hands-free operation. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. NOTE: Water will not flow from bubbler unless unit is connected to electricity. |
| MOUNTING HEIGHT Mounting height recommended 30 1/4˝ from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall with six fasteners. To insure proper engaging of waste line into trap, centerline of trap must be 7˝ from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Connect service stop to solenoid valve using 3/8˝ supply tube. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water - 20 to 105 psi ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. Legend: A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN C = 1-1/4” TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F = 5/16" BOLT HOLES FOR FASTENING UNIT TO WALL When replacing a model ‘HAC’ with a new unit ‘HTV’, installer must cut 1-7/8" from length of cooler waste line before connecing to trap. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HTV8EE-Q | 9.6 | 8.8 | 7.6 | 7.2 | 7.6 | 4.5 | 51 | 360 |
![]() |
![]() Front View |
![]() Side View |
| GENERAL Self-contained, electric refrigerated wall-mounted water cooler with softly rounded corners and edges, designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children and adults. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. LEAD REDUCTION FILTER Halsey Taylor Water Cooler With Filter is equipped with the Aqua Sentry HWF142 lead reduction system which is designed to remove cysts, such as cryptrosporidium and giardia, lead particles and chlorine taste and odor. The filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst. Features include Quick-Disconnect fittings on each end of the in-line filter. The filter contains a carbon block with lead sorbent media and the housing is made of rust and corrosion free plastic. Filter should be replaced every 750 gallons (2839 liters) or approximately 6 months after installation. Use part number 56191C when ordering replacement filter. CABINET Molded two-tone gray space-age polymer with softly rounded edges. Resistant to impact, wear, corrosion, heat and sunlight. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash design reduces splatter. Contour design and integral strainer insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC ACTUATION Model HTV8EE-Q features infra-red light beam emitting sensor and a solenoid valve. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. The water flow is automatically shut-off after 30 seconds or earlier if the user leaves the sensing range. Supplied with a built-in time delay to avoid nuisance actuation from passers-by. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. SOLENOID VALVE / INLET STRAINER Self-closing solenoid valve includes easily cleaned in-line strainer that screens particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 7.6 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with integral drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have electronic eye water control for hands-free operation. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. NOTE: Water will not flow from bubbler unless unit is connected to electricity. |
| MOUNTING HEIGHT Mounting height recommended 30 1/4" from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall with six fasteners. To insure proper engaging of waste line into trap, centerline of trap must be 7" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Connect service stop to solenoid valve using 3/8" supply tube. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water - 20 to 105 psi ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. Legend: A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN C = 1-1/4” TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F = 5/16" BOLT HOLES FOR FASTENING UNIT TO WALL When replacing a model ‘HAC’ with a new unit ‘HTV’, installer must cut 1-7/8" from length of cooler waste line before connecing to trap. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HTV8EE-WF-Q | 9.6 | 8.8 | 7.6 | 7.2 | 7.6 | 4.5 | 53 | 360 |
![]() |
![]() |
![]() |
| MOUNTING HEIGHT Mounting height recommended 30 1/4" from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall with six fasteners. To insure proper engaging of waste line into trap, centerline of trap must be 7" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Connect service stop to solenoid valve using 3/8" supply tube. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water - 20 to 105 psi. Minimum 40 psi supply line pressure required in special circumstances when both sides of bilevel are in use simultaneously to ensure adequate stream height. Does not apply to non-refrigerated units. ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. Legend: A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN C = 1-1/2" TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX (DUPLEX REQUIRED) E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F = 5/16" BOLT HOLES FOR FASTENING UNIT TO WALL |
| GENERAL Self-contained, electric refrigerated wall-mounted bi-level water cooler with softly rounded corners and edges, designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children and adults. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Molded two-tone gray space-age polymer with softly rounded edges. Resistant to impact, wear, corrosion, heat and sunlight. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash design reduces splatter. Contour design and integral strainer insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSH BAR ACTUATION MECHANISM Self-closing light-touch push bars require minimal pressure to activate. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. SOLENOID VALVE / INLET STRAINER Self-closing solenoid valve includes easily cleaned in-line strainer that screens particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 7.6 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with integral drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, evaporator tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have push-bar water controls. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61 and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. NOTE: Water will not flow from bubbler unless unit is connected to electricity. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HTV8BL-Q | 9.6 | 8.8 | 7.6 | 7.2 | 7.6 | 4.5 | 78 | 360 |
![]() |
![]() |
![]() |
| MOUNTING HEIGHT Mounting height recommended 30 1/4˝ from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall with six fasteners. To insure proper engaging of waste line into trap, centerline of trap must be 7˝ from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Connect service stop to solenoid valve using 3/8˝ supply tube. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water - 20 to 105 psi. In special circumstances where both sides of unit may be used simultaneously it is preferable to install two single filtered units to obtain adequate stream height regardless of pressure. Does not apply to non-refrigerated units. ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. Legend: A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN C = 1-1/2" TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX (DUPLEX REQUIRED) E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F = 5/16" BOLT HOLES FOR FASTENING UNIT TO WALL |
| GENERAL Self-contained, electric refrigerated wall-mounted bi-level water cooler with softly rounded corners and edges, designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children and adults. Unit is certified to NSF/ANSI 61, and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. LEAD REDUCTION FILTER Halsey Taylor Water Cooler With Filter is equipped with the Aqua Sentry HWF142 lead reduction system which is designed to remove cysts, such as cryptrosporidium and giardia, lead particles and chlorine taste and odor. The filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst. Features include Quick-Disconnect fittings on each end of the in-line filter. The filter contains a carbon block with lead sorbent media and the housing is made of rust and corrosion free plastic. Filter should be replaced every 750 gallons (2839 liters) or approximately 6 months after installation. Use part number 56191C when ordering replacement filter. CABINET Molded two-tone gray space-age polymer with softly rounded edges. Resistant to impact, wear, corrosion, heat and sunlight. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash design reduces splatter. Contour design and integral strainer insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSH BAR ACTUATION MECHANISM Self-closing light-touch push bars require minimal pressure to activate. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. SOLENOID VALVE / INLET STRAINER Self-closing solenoid valve includes easily cleaned in-line strainer that screens particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 7.6 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with integral drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, evaporator tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have push-bar water controls. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. NOTE: Water will not flow from bubbler unless unit is connected to electricity. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HTV8BL-WF-Q | 9.6 | 8.8 | 7.6 | 7.2 | 7.6 | 4.5 | 80 | 360 |
![]() |
![]() |
![]() |
| MOUNTING HEIGHT Mounting height recommended 30 1/4˝ from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall with six fasteners. To insure proper engaging of waste line into trap, centerline of trap must be 7˝ from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Connect service stop to solenoid valve using 3/8˝ supply tube. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water - 20 to 105 psi. Minimum 40 psi supply line pressure required in special circumstances when both sides of bilevel are in use simultaneously to ensure adequate stream height. Does not apply to non-refrigerated units. ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. Legend: A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN C = 1-1/2" TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX (DUPLEX REQUIRED) E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F = 5/16" BOLT HOLES FOR FASTENING UNIT TO WALL |
| GENERAL Self-contained, electric refrigerated wall-mounted bi-level water cooler with softly rounded corners and edges, designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children and adults. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Molded two-tone gray space-age polymer with softly rounded edges. Resistant to impact, wear, corrosion, heat and sunlight. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash design reduces splatter. Contour design and integral strainer insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC ACTUATION Model HTV8BLEE-Q features infra-red light beam emitting sensor and a solenoid valve. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. The water flow is automatically shut-off after 30 seconds or earlier if the user leaves the sensing range. Supplied with a built-in time delay to avoid nuisance actuation from passers-by. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. SOLENOID VALVE / INLET STRAINER Self-closing solenoid valve includes easily cleaned in-line strainer that screens particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 7.6 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with integral drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, evaporator tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have electronic eye water controls for hands-free operation. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. NOTE: Water will not flow from bubbler unless unit is connected to electricity. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HTV8BLEE-Q | 9.6 | 8.8 | 7.6 | 7.2 | 7.6 | 4.5 | 80 | 360 |
![]() |
![]() |
![]() |
| MOUNTING HEIGHT Mounting height recommended 30 1/4˝ from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall with six fasteners. To insure proper engaging of waste line into trap, centerline of trap must be 7" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Connect service stop to solenoid valve using 3/8" supply tube. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water - 20 to 105 psi. In special circumstances where both sides of unit may be used simultaneously it is preferable to install two single filtered units to obtain adequate stream height regardless of pressure. Does not apply to non-refrigerated units. ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. Legend: A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN C = 1-1/2" TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX (DUPLEX REQUIRED) E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F = 5/16" BOLT HOLES FOR FASTENING UNIT TO WALL |
| GENERAL Self-contained, electric refrigerated wall-mounted bi-level water cooler with softly rounded corners and edges, designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children and adults. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. LEAD REDUCTION FILTER Halsey Taylor Water Cooler With Filter is equipped with the Aqua Sentry HWF142 lead reduction system which is designed to remove cysts, such as cryptrosporidium and giardia, lead particles and chlorine taste and odor. The filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst. Features include Quick-Disconnect fittings on each end of the in-line filter. The filter contains a carbon block with lead sorbent media and the housing is made of rust and corrosion free plastic. Filter should be replaced every 750 gallons (2839 liters) or approximately 6 months after installation. Use part number 56191C when ordering replacement filter. CABINET Molded two-tone gray space-age polymer with softly rounded edges. Resistant to impact, wear, corrosion, heat and sunlight. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash design reduces splatter. Contour design and integral strainer insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC ACTUATION Model HTV8BLEE-WF-Q features infra-red light beam emitting sensor and a solenoid valve. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. The water flow is automatically shut-off after 30 seconds or earlier if the user leaves the sensing range. Supplied with a built-in time delay to avoid nuisance actuation from passers-by. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. SOLENOID VALVE / INLET STRAINER Self-closing solenoid valve includes easily cleaned in-line strainer that screens particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 7.6 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with integral drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, evaporator tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have electronic eye water controls for hands-free operation. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. NOTE: Water will not flow from bubbler unless unit is connected to electricity. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HTV8BLEE-WF-Q | 9.6 | 8.8 | 7.6 | 7.2 | 7.6 | 4.5 | 80 | 360 |
![]() |
![]() |
| MOUNTING HEIGHT Mounting height recommended 281/2˝ from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 7˝ from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Install 3/8 supply tube to in-line strainer. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. A. RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 IN. (38 mm) OUT FROM WALL SHUT OFF BY OTHERS B. RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4˝ O.D. DRAIN C. 1-1/4˝ TRAP NOT FURNISHED** D. ELECTRICAL SUPPLY (3) WIRE RECESSED BOX E. INSURE PROPER VENTILATION BY MAINTAINING 6˝ (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F. 7/16˝ BOLT HOLES FOR FASTENING UNIT TO WALL |
| GENERAL Self-contained, electric refrigerated wall-mounted water cooler easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements for both children and adults as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61, and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints. COOLER TOP Non-corrosive stainless steel cooler top, no. 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSH BAR ACTUATION MECHANISM Self-closing light-touch push bars on front and sides with raised letters for the visually impaired. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have front and side push-bar water controls with raised lettering for the visually impaired. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes See Halsey Taylor website for most current spec sheet. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HAC8FS-Q CHILD SS | 9.6 | 8.8 | 8.0 | 7.2 | 8.0 | 3.7 | 63 | 325 |
![]() |
![]() |
| MOUNTING HEIGHT Mounting height recommended 281/2" from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 7" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Install 3/8" supply tube to in-line strainer. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. A. RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 IN. (38 mm) OUT FROM WALL SHUT OFF BY OTHERS B. RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4˝ O.D. DRAIN C. 1-1/4˝ TRAP NOT FURNISHED** D. ELECTRICAL SUPPLY (3) WIRE RECESSED BOX E. INSURE PROPER VENTILATION BY MAINTAINING 6˝ (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F. 7/16˝ BOLT HOLES FOR FASTENING UNIT TO WALL |
| GENERAL Self-contained, electric refrigerated wall-mounted water cooler easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements for both children and adults as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61, and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC ACTUATION Model HAC8EE-Q CHILD features infra-red light beam emitting sensor and a solenoid valve. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. The water flow is automatically shut-off after 30 seconds or earlier if the user leaves the sensing range. Supplied with a built-in time delay to avoid nuisance actuation from passers-by. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have electronic eye water controls for hands-free operation. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes See Halsey Taylor website for most current spec sheet. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HAC8EE-Q CHILD SS | 9.6 | 8.8 | 8.0 | 7.2 | 8.0 | 3.7 | 63 | 325 |
![]() |
![]() |
| MOUNTING HEIGHT Mounting height recommended 3113/16" from basin to floor. May be mounted at any desired height. Check local codes. MOUNTING INSTRUCTIONS Mount trap and install service stop to supply line. Anchor hanger bracket securely to wall on all sides. To insure proper engaging of waste line into trap, centerline of trap must be 61/4" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Install 3/8" supply tube to in-line strainer. Secure bottom of cooler to wall using holes provided. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum ELECTRICAL 120 Volt / 60 Hz units furnished with plug-in, 3 wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120 volt receptacle rated at 15-amp minimum to receive 3-wire parallel blade grounding type male plug. 220 Volt units furnished with universal plug receptacle. |
| GENERAL Self-contained, electric refrigerated wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children and adults. Unit is certified to NSF/ANSI 61, and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. Unit is UL listed for indoor and outdoor service. CABINET Stainless steel panels resists wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Vandal-resistant bubbler is one-piece, chromeplated. Unit has integral hood guard design to prevent contamination from other users, airborne deposits and tampering. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 7.8 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be one-piece, vandalresistant. Separate valve and automatic streamregulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Unit shall comply with ANSI 117:1 and ADA for visual and motion disabilities. Unit shall be UL listed for outdoor service. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HVR8-CHILD ADA | 9.6 | 8.8 | 8.0 | 7.2 | 7.8 | 5.0 | 66 | 525 |
![]() |
![]() |
| GENERAL Self-contained, electric refrigerated, bi-level wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit on right side meets state and federal requirements for both children and adults as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61, and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. Unit is UL listed for indoor and outdoor service. CABINET Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Vandal-resistant bubbler is one-piece, chrome-plated, with integral hood guard design to prevent contamination from other users, airborne deposits and tampering. PUSHBUTTON ACTUATION MECHANISM Self-closing, vandal-resistant pushbutton does not require grasping or twisting. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 7.8 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be one-piece, vandal resistant type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, evaporator/tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HVR8BL-CHILD ADA | 9.6 | 8.8 | 8.0 | 7.2 | 7.8 | 5.0 | 94 | 575 |
![]() |
![]() |
| MOUNTING INSTRUCTIONS Locate and secure wall hangers to wall. Note location of waste trap (in right side unit). To insure proper engaging of waste line into trap, centerline of trap must be 5" from wall face. Mount handicap (refrigerated) unit on right wall bracket and secure cabinet to wall using holes in lower back of frame. Mount fountain (nonrefrigerated) unit on left wall bracket and against left side of handicap unit. Secure cabinet to wall using holes in lower back of frame. Install connecting waste line to tailpieces on both units. Insulated water line furnished to connect fountain to handicap unit. Connect building water supply line to “water inlet” connection on handicap unit. Complete instructions packed with unit. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances when both sides of bilevel are in use simultaneously to ensure adequate stream height. Does not apply to non-refrigerated units. ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. |
| GENERAL Self-contained, electric refrigerated, bi-level wall-mounted water cooler easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements for both children and adults as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61, and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints. COOLER TOP Non-corrosive stainless steel cooler top, no. 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. PUSH BAR ACTUATION MECHANISM Self-closing, light-touch push bars on front and sides with raised letters for the visually impaired. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have front and side push-bar water controls with raised lettering for the visually impaired. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HAC8FSBL-Q CHILD SS | 9.6 | 8.8 | 8.0 | 7.2 | 8.0 | 3.7 | 92 | 325 |
![]() |
![]() |
| MOUNTING INSTRUCTIONS Locate and secure wall hangers to wall. Note location of waste trap (in right side unit). To insure proper engaging of waste line into trap, centerline of trap must be 5˝ from wall face. Mount handicap (refrigerated) unit on right wall bracket and secure cabinet to wall using holes in lower back of frame. Mount fountain (nonrefrigerated) unit on left wall bracket and against left side of handicap unit. Secure cabinet to wall using holes in lower back of frame. Install connecting waste line to tailpieces on both units. Insulated water line furnished to connect fountain to handicap unit. Connect building water supply line to “water inlet” connection on handicap unit. Complete instructions packed with unit. Trap and service stop not included. OPERATING PRESSURES: Supply water - 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances when both sides of bilevel are in use simultaneously to ensure adequate stream height. Does not apply to non-refrigerated units. ELECTRICAL Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug. A. RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 IN. (38 mm) OUT FROM WALL SHUT OFF BY OTHERS B. RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/ 2˝ O.D. DRAIN C. 1-1/2˝ TRAP NOT FURNISHED** D. ELECTRICAL SUPPLY (3) WIRE RECESSED BOX E. INSURE PROPER VENTILATION BY MAINTAINING 6˝ (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL F. 7/16˝ BOLT HOLES FOR FASTENING UNIT TO WALL |
| GENERAL Self-contained, electric refrigerated, bi-level wall-mounted water cooler easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements for both children and adults as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61, and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient. CABINET Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints. COOLER TOP Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage. BUBBLER Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water. AUTOMATIC ACTUATION Model HAC8EEBL-Q CHILD features infra-red light beam emitting sensor and a solenoid valve. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. The water flow is automatically shut-off after 30 seconds or earlier if the user leaves the sensing range. Supplied with a built-in time delay to avoid nuisance actuation from passers-by. AUTOMATIC STREAM HEIGHT REGULATOR Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. INLET STRAINER Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway. TEMPERATURE CONTROL Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F. STORAGE TANK Stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act. REFRIGERATION SYSTEM Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty. VENTILATION Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall. SUGGESTED SPECIFICATIONS Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, evaporator/tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have electronic eye water controls for hands-free operation. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010. NOTE: Continued product improvement makes specifications subject to change without notice. |
| Model No. | GPH Capacity Cooled to 50º F |
Base Rate Cap. |
F.L. Amps |
Shipping Weight lbs. |
Rated Watt Usage |
|||
| Ambient Air Temp | ||||||||
| 70º F | 80º F | 90º F | 100º F | |||||
| HAC8EEBL-Q CHILD SS | 9.6 | 8.8 | 8.0 | 7.2 | 8.0 | 3.7 | 100 | 325 |
| WSP home page | Products page | Suppliers page |
| Fountains & Coolers | Halsey Taylor Index | Next Halsey Taylor Page |