Gas detectors are designed for monitoring the environment by one of two methods, diffusion or sample draw. In the case of diffusion, natural forces are relied upon to cause the ambient air to interact with the gas sensor. As an alternative, the air sample can be drawn to the sensor using either a hand-operated, squeeze-bulb aspirator or a motorized sample pump. Obviously, the motorized pump is much more convenient and easier to use, and it can provide a continuous air sample to the sensor at a constant flow rate. Sample draw reduces gas response time compared to natural diffusion, and it facilitates testing of valves, pipe connections, etc. for leaks, and enables the monitoring of remote areas or enclosed vessels where non-ambient conditions may exist, such as, temperature extremes. A properly designed sample draw system can improve the monitoring performance for most gases, particularly acid gases like CIg and HCI. It also reduces the response times for gases to be detected at sub-ppm con-centrations, such as, AsH3. And, most important, sample draw is required for the detection of some gases, most notably, HF and O3. It is for these reasons that the SPECTRUM SP Series was developed.
|
|
| Specifications | |
| Size | 5 x 4.75 x 2 inches (127 x 120 x 50 mm) |
| Weight | 13 oz. (370 g) |
| Enclosure | ABS plastic |
| Power | Rechargeable 4.8 volt NiMH battery |
| Display | 8 character, high contrast dot matrix LCD with backlight |
| Sensor | Electrochemical |
| Alarm Points | Two (high/low), audio & visual |
| Audible Alarm | 75 dB at 10 cm, confidence chirp every 30 seconds |
| Visual Alarm | Red LED |
| Temp Range | 14 to 133ºF (-10 to +45ºC) |
| Part No. | Gas Detected | Range | LDL (1) | Alarm (2) | Alarm (3) | Life (4) | Cal/Test |
| 04818-0100 | Chlorine, Cl2 | 10.0 ppm | 0.5 ppm | 1 ppm | 5 ppm | 1-2 years | 5 |
| 04818-0200 | Hydrogen sulfide, H2S | 200 ppm | 5 ppm | 10 ppm | 25 ppm | 2-3 years | 5 |
| 04818-0400 | Hydrogen chloride, HCl | 20.0 ppm | 1 ppm | 5 ppm | 10 ppm | 1 year | 5 |
| 04818-0500 | Sulfur dioxide, SO2 | 20.0 ppm | 1 ppm | 5 ppm | 10 ppm | 2-3 years | 5 |
| 04818-0700 | Hydrogen fluoride, HF | 10.0 ppm | 1 ppm | 3 ppm | 6 ppm | 1 year | 6 |
| 04818-0800 | Ozone, O3 | 0.99 ppm | 0.05 ppm | 0.10 ppm | 0.20 ppm | 1 year | 7 |
| 04818-1200 | Carbon monoxide, CO | 1000 ppm | 5 ppm | 35 ppm | 200 ppm | 2-3 years | 5 |
| 04818-1500 | Hydrogen, H2 | 1000 ppm | 30 ppm | 200 ppm | 750 ppm | 2-3 years | 5 |
| 04818-1700 | Nitrogen dioxide, NO2 | 10.0 ppm | 1.5 ppm | 3 ppm | 5 ppm | 1-2 years | 5 |
| 04818-1750 | Nitric oxide NO | 100 ppm | 5 ppm | 25 ppm | 50 ppm | 1-2 years | 5 |
| 04818-2400 | Ammonia, NH3 | 100 ppm | 7 ppm | 25 ppm | 50 ppm | 1 year | 5 |
| 04818-4001 | Arsine, AsH3 | 0.99 ppm | 0.05 ppm | 0.05 ppm | 0.10 ppm | 1 year | 5 |
| 04818-4003 | Silane, SiH4 | 30 ppm | 4 ppm | 5 ppm | 10 ppm | 1 year | 5 |
| (1) Lower Detectable Limit calculated from baseline noise level, thermal drift and interference data used to derive zero point deviation estimates | |||||||
| (2) Alarm adjustable, audio alarm acknowledgeable (can be silenced) | |||||||
| (3) Audio alarm reactivation, not acknowledgeable (cannot be silenced) | |||||||
| (4) Typical sensor life | |||||||
| (5) Gas cylinder and regulator available for calibration | |||||||
| (6) See HF permeation tube test kit | |||||||
| (7) See O3 generator test kit | |||||||
| Description | Part No. | Description | Part No. |
| HF Perm Tube Test Kit, with manual | 04567-0702 | Case, Gas Reg. and up to two 17 or 34 L cylinders | 73083-000 |
| O3 Generator Test Kit, 110 VAC with manual | 04056-0800-4 | Sampling Probe, 4' tubing w/10" rigid probe | 03700-032 |
| O3 Generator Test Kit, 220 VAC with manual | 04056-0800-5 | Battery for Spectrum SP, 4.8 V NiMH | 67019-027 |
| Gas Reg., flow demand, for 17L cyl. | 03510-001 | Charger for Spectrum SP, 110 VAC | 67051-006 |
| Gas Reg., flow demand, for 34L cyl. | 03510-002 | Charger for Spectrum SP, 220 VAC | 67051-010 |
| Connector Tube for Gas Reg./Sampling Probe | 03700-033 | Manual for Spectrum SP | 80012-018 |
![]() |
![]() |
![]() |
| Ozone Generator Test Kit Accessories not shown |
34 & 17 liter calibration gas cylinders, regulators and connector tube | HF Permeation Test Kit |
![]() |
![]() |
|
|
| Gas | Range | Gas | Range | Gas | Range |
| EXP* | 100% LEL | NO | 300 | H2 | 2000 |
| CH4 | 100% LEL | NO2 | 30.0 | AsH3 | 1.00 |
| O2 | 30% vol | Cl2 | 10.0 | SiH4 | 50 |
| CO | 1000 | HCl | 30.0 | O3 | 1.00 |
| H2S | 100 | HCN | 30.0 | HF | 10.0 |
| SO2 | 30.0 | NH3 | 100 | CO2 | 5.0% vol |
| * Calibrated with methan and programmed for 32 gases/vapors, including propane, butane, hexane, etc. | |||||
| Function | Multigas detector | Power source | Encapsulated NiMH battery pack (rechargeable, standard) or 3 AAA alkaline batteries |
| Configuration | 3 channels: toxic gases, H2, O2 1 channel for explosive gases |
Charger | 12 to 30 volts DC |
| Sensors | Smart, precalibrated, interchangeable without adjustment Automatic sensor recognition |
Charging Time | 3 hours State of charge displayed |
| Display | Graphic LCD, text display of gas levels, Backlighting | Operating Temp. | 15ºF to 105ºF (-10ºC to +40ºC) continuous use 10ºF to 120ºF (-25ºC to +50ºC) intermittent use |
| Auto-Zero | On demand, key function Charger disconnect (option) |
Ingress Protection | IP 66 |
| Gas Alarms | Text message on display, for each channel Flashing light signal, common to all channels Audible signal, first alarm Vibratory warning, first alarm |
Weight | 12 ounces (350 g) |
| Alarm Levels | 2 instantaneous thresholds, per channel for LEL, O2, ppm H2, and toxid sensors | Outputs (options) | RS 232 infrared link direct to printer for reviews to PC , maintenance and supervision software including text output for Excel |
| Operating Check | Self test at start up Audible tone (factory set interval) |
||
| Warning Lights | 360º visibility | ||
| Audible Alarm | 95 dB at 12 inches (30 cm) | ||
| Approvals | II 1G EEx ia IIC T4 (industry) I M1 EEx ia IIC T4 (mining) With IR/MOS sensor: II 2G/I M2 EEx ia d IIC T4 INERIS 03 ATEX 0216 |
||
| Part No. | Description |
| Instrument Package with Common Sensors | |
| 02610-000 | MX-2100 Instrument with audio, visual and vibratory alarms, calibration shield/charger interface, power supply and CO, H2S, O2 and LEL sensors |
| Instrument Package without Sensors | |
| 02610-020 | MX-2100 Instrument with audio, visual and vibratory alarms, calibration shield/charger interface and power supply, without sensors |
| See chart below for sensor specifications, part numbers and ordering information | |
| Accessories | |
| 02612-005 | Protective cover with harness |
| 02612-006 | Protective cover without harness |
| 02612-010 | Sampling pump (Also order p/n 03700-018 wand with probe or p/n 03700-031 hose, or both) |
| 03700-018 | Wand, 22 in. probe with 2 ft. hose |
| 03700-031 | Hose, 20 ft. with connector |
| 02602-011 | Hand aspirator with 12 ft. hose |
| 02602-010 | Hand aspirator with 27 in. probe and 3 ft. hose |
| 73083-006 | Transit case |
| 02612-012 | Software kit, COM2100, with IR/Serial cable |
| 66014-002 | Charger Adapter, 12 V DC |
| Part # | Gas & Unit of Measurement |
Range | LDL (5) | Low Alarm |
High Alarm |
TWA Alarm |
STEL Alarm |
Life (6) |
Temp ºC |
| 02613-001-E (1) | Combustible gas, % LEL (4) | 100% LEL | 1% LEL | 10% LEL | 50% LEL | N/A | N/A | 24 | -20 to +75 |
| 02613-0100-S (2) | Chlorine, Cl2, ppm | 10 ppm | 0.5 ppm | 0.5 ppm | 1 ppm | 0.5 ppm | 1 ppm | 24 | -10 to +40 |
| 02613-0200-S (1) | Hydrogen sulfide, H2S, ppm | 100 ppm | 5 ppm | 10 ppm | 15 ppm | 10 ppm | 15 ppm | 24 | -10 to +40 |
| 02613-0300-S | Hydrogen cyanide, HCN, ppm | 30 ppm | 1 ppm | 4.7 ppm | 10 ppm | 4.7 ppm | 4.7 ppm | 18 | -10 to +40 |
| 02613-0400-S (2) | Hydrogen chloride, HCl, ppm | 30 ppm | 1 ppm | 5 ppm | 10 ppm | 5 ppm | 5 ppm | 18 | -10 to +40 |
| 02613-0500-B | Sulfur dioxide, SO2, ppm | 30 ppm | 1 ppm | 2 ppm | 5 ppm | 2 ppm | 5 ppm | 24 | -10 to +40 |
| 02613-0700-S (3) | Hydrogen fluoride, HF, ppm | 10 ppm | 1 ppm | 2 ppm | 4 ppm | 3 ppm | 3 ppm | 18 | -10 to +40 |
| 02613-0800-S (3) | Ozone, O3, ppm | 1 ppm | 0.05 ppm | 0.1 ppm | 0.2 ppm | 0.05 ppm | 0.2 ppm | 18 | -10 to +40 |
| 02613-1100-B (1) | Oxygen, O2, % by vol | 30% V | 0.3%V | 19.5%V | 23.5%V | N/A | N/A | 12 | -10 to +40 |
| 02613-1200-S (1) | Carbon monoxide, CO, ppm | 1000 ppm | 5 ppm | 35 ppm | 100 ppm | 25 ppm | 200 ppm | 24 | -10 to +40 |
| 02613-1350-B | Carbon dioxide, % by vol | 5.0%V | 0.1%V | 0.5%V | 1%V | 0.5%V | 3%V | 30 | -10 to +40 |
| 02613-1500-S | Hydrogen, H2, ppm | 2000 ppm | 30 ppm | 200 ppm | 2000 ppm | N/A | N/A | 24 | -10 to +40 |
| 02613-1700-S | Nitrogen dioxide, NO2, ppm | 30 ppm | 1.5 ppm | 2 ppm | 4 ppm | 3 ppm | 5 ppm | 24 | -10 to +40 |
| 02613-1750-S | Nitric oxide, NO, ppm | 300 ppm | 5 ppm | 25 ppm | 50 ppm | 25 ppm | 25 ppm | 24 | -10 to +40 |
| 02613-2200-B | CO/H2S Combo sensor, ppm | See Carbon monoxide and Hydrogen sulfide sensor data | |||||||
| 02613-2400-S | Ammonia, NH3, ppm | 100 ppm | 7 ppm | 25 ppm | 50 ppm | 25 ppm | 35 ppm | 18 | -10 to +40 |
| 02613-4001-S (2) | Arsine, AsH3, ppm | 1 ppm | 0.05 ppm | 0.05 ppm | 0.1 ppm | 0.05 ppm | 0.1 ppm | 18 | -10 to +40 |
| 02613-4003-S | Silane, SiH4, ppm | 50 ppm | 4 ppm | 10 ppm | 20 ppm | 5 ppm | 15 ppm | 18 | -10 to +40 |
| (1) These are the replacement sensors for the standard instrument package, p/n 02610-0000 Warranty for the standard instrument package, including CO, H2S, LEL and O2 is 18 months from date of shipment Warranty for all other sensors and accessories is 12 months from date of shipment |
|||||||||
| (2) For best performance, it is recommended that a sample pump be used for monitoring these gases | |||||||||
| (3) A sample pump is required for monitoring these gases | |||||||||
| (4) Calibrated with methane and programmed for 32 combustible gases/vapors including propane, butane, hexane, etc | |||||||||
| (5) Lower Detectable Limit calculated from baseline noise level, thermal drift and interference data used to derive zero point deviation estimates | |||||||||
| (6) Typical sensor life in months | |||||||||
![]() |
![]() |
| The Formaldemeter htV offers a simple way to monitor levels of airborne formaldehyde in the environment. The instrument is easy to use with a simple four button keypad and features an easy-to-read four digit display. It employs a well-proven electrochemical formaldehyde sensor that will provide an immediate indication of formaldehyde levels. Unlike other formaldehyde monitoring devices, such as color stain tubes and badges, the Formaldemeter htV is capable of measuring many samples consecutively without the need for inconvenient ancillary equipment. Real-time results also mean that potential overexposures can be identified as they occur, without the delay and expense associated with laboratory analysis. Also available: the Glutaraldemeter 3 for glutaraldehyde monitoring
|
|
| Applications: Formaldehyde is a common contaminant found in new construction, residential housing and commercial buildings following renovation. It is used in many products, industries and other types of activities, including: Textile treatment |
|
| Specifications below: | |
| Sensor: | Electrochemical |
| Calibration: | In-field formaldehyde calibration standard |
| Display: | 4-digit LCD |
| Sampling Frequency: | Typically once every 3 to 5 minutes depending on previous reading |
| Sample volume: | Approx. 10 ml |
| Detection range: | 0.05 - 10 ppm (optional high range: 80 ppm) |
| Precision: | 10% at 2 ppm level |
| Response time: | <10 seconds |
| Temperature: | By key interrogation, displayed in degrees C |
| Humidity: | By key interrogation, displayed in % rH |
| Power: | 9 volt alkaline battery |
| Enclosure: | ABS plastic |
| Weight: | Instrument: 10 oz. Complete Kit: 1.75 lbs. |
| Dimensions: | Instrument: 6 x 3.25 x 1.25 inches Carrying Case: 10.5 x 8.5 x 2 inches |
Sampling:
High levels, i.e., over 1 ppm, can take at least 5 minutes to "clear" from the sensor. If formaldehyde is detected, wait 3 - 5 minutes before turning instrument ON for next sample. To take another sample, repeat above steps. Retrieval of stored data - instrument automatically stores the last ten readings
|
|
| Cross Sensitivity Chart | |
| Compound | ppm to = 1 ppm reading |
| Acetone | No response |
| Acetaldehyde | 8 - 12 |
| Acetic Acid | No response |
| Ammonia | 71000 |
| Butanol | Note (2) |
| Carbon monoxide | 100 |
| Ethylene | 160 |
| Ethanol | 12 - 20 |
| Formaldehyde | 1.0 |
| Glutaraldehyde | 7100 at 25ºC Note (3) |
| Methanol | 50 |
| Phenol | 5, Note (1) |
| Propanol | Note (2) |
| Resorcinol | 5, Note (1) |
| Note (1) | Completely removed with filter provided |
| Note (2) | Interference above 60ºC and 20 ppm |
| Note (3) | Monitor with Glutaraldemeter 3 |
| Accessories and Replacement Parts:
Phenol Filters (supplied with instrument kit) Calibration Standard (supplied with instrument kit) Options: AMS-2 Base Unit |
|
| Ordering Information for Formaldemeter | |
| Part Number | Description |
| 02700-100 | Instrument kit with Formaldemeter htV, 10 phenol filters, thermometer, pen, calibration standard, instruction manual and case |
| 02710-000 | Instrument kit with Glutaraldemeter 3, 10 phenol filters, thermometer, pen, calibration standard, instruction manual and case |
| 02700-251 | Optional data logging station, Model AMS-2 Base Unit for htV |
| 02700-256 | Optional PC download software for AMS-2/htV |
| 02700-001 | Formaldehyde Calibration Standard, typical life 6 to 12 months |
| 02710-001 | Glutaraldehyde Calibration Standard, typical life 6 to 12 months |
| 02700-002 | Replacement Phenol Filters, pack of 10 |
| 02700-003 | Replacement Formaldehyde Sensor, typical life 3 - 4 years |