Enmet Gas Detectors Page 2

For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

Credit Cards Image

Stationary Monitors (ISA Series)
ISA-40 Oxygen Monitor
Oxygen monitor
Specifications:
Size / Wt.: 305 x 215 x 175 mm, 4 Kg
Enclosure: NEMA-4X fiberglass
Meter display: 16 to 26% by Volume
Alarm point calibration:
19.5% by Volume
Relays, Auxiliary: One latching SPDT (NO, NC) relay per channel; 2 amps steady, 5 amps surge
Power: 110 / 220 VAC and / or 12 VDC
Sensor type: Galvanic micro fuel cell
Temperature range: 0 to 50 degrees C
Sensor life: Average 12 to 15 months
ISA-44 Series multi channel systems
ISA-44 series instruments feature MOS sensors for CO, H2S and ppm or LEL levels of organic solvents. Oxygen monitoring capability can also be included. ISA-44 systems are available for up to 10 channels
Examples of ISA-44 calibrations:

CO: 35 and 100 ppm
Ammonia: 50 and 100 ppm
Methane: 10 and 20% LEL
Hydrogen: 10 and 20% LEL
Freon® 113: 500 and 1000 ppm
H2S: 10 and 20 ppm
Gasoline: 10 and 20% LEL
Propane: 10 and 20% LEL

Calibrations available for HCN, ETO, Jet fuels, Ketones, Alcohols, Ethers, Halogenated hydrocarbons, Solvents, Esters, Butane, Hexane and others

Stationary Monitors (Enguard Series)
Enguard 97D
Stand alone
Enguard MX-32
1 - 2 channels
Controller with integral or remote toxic sensor
The economical Enguard 97D stand alone controller features either and integrated toxic gas sensor or an optional remote sensor and cable. Electrochemical sensors are available for O2 and a wide range of toxic gases
  • Integral or remote sensor and cable
  • Audio & Visual alarms
  • 4 - 20 mA output signal
  • 3 factory programmable alarms
  • 5 VDC TTL outputs
  • 85 - 265 VAC or 24 VDC power
  • IP 65 polycarbonate enclosure
  • Digital display
  • Push button calibration
  • 1 alarm rely, user selectable

Controllers for remote sensors / Transmitters
The Enguard series is an economical, versatile and reliable state of the art system designed to detect and monitor many different toxic and combustible gases. Single and multichannel systems are available.
  • Audio and Visual alarms
  • 4 - 20 mA
  • Digital display
  • One person calibration
  • Wall, panel or rack mount controllers available
  • For 24 VDC, 2 and 3 wire sensor / transmitters

Also available:
MX -42A: 1 to 4 channels
MX-48: 1 to 8 channels
MX-52: 1 to 16 channels

Sensors and Transmitters
SDS-97D Series with digital display EX-5100-MOS with MOS sensor (ppm solvents)
EN-Series without digital display IR-6000 with infrared sensor (0 - 100% LEL)
  • 24 VDC loop powered
  • 4 - 20 mA output
  • Electrochemical sensors
  • Excellent selectivity
  • One person calibration
Available for these gases:

AsH3, B2H6, Cl2, ClO2, CO, CO2, COCl2, ETO, HCl, HCN, HF, H2, H2S, NH3, NO, NO2, N2H4, O2, O3, PH3, SiH4, SO2, VCM, HCHO, F2, SiH2Cl2, HBr, BCl3, SF4, WF6, H2Se, Si2H6, Br2, I2, NF3, SF6

Note: sample pump required for some gases

CO and O2 Air Line Monitors
ISA-RAL-M ISA-200
Specifications:

Alarm point: 10 ppm or 20 ppm CO
Meter: Full scale at 50 ppm CO
Operating power: 110 VAC and / or 12 VDC, 60 Hz, 25 watts
Operating temperature limits: 0 to 125 degrees F
Sensor: MOS solid state gas sensor. Typical life up to 3 years
Inlet pressure: Maximum 250 psi
Enclosure: NEMA-12
Size: 8" H x 6"W x 4"D
Weight: 10 lbs.
Wiring: Line cord supplied for 110 VAC operation
Sensor cable length: Supplied with 10 ft. sensor cable
Audio alarm: 2900 Hz, 90 dB at 2 feet
Hydrocarbon Filter Assembly: Designed to eliminate trace hydrocarbons which are present in some compressed air systems

Specifications:

CO and O2 Monitor
Alarm points: 10 ppm CO (adjustable), 19.5% O2 (adjustable), 23.5% O2 (non adjustable) and Fault
Display: 2 line, 16 character, dot matrix LCD
Operating Power: 100 to 240 VAC and / or 12 VDC, 15 watts, supplied with 110 VAC line cord
Auxiliary Relays: RAL, 2 relays, CO and Fault. RAL-O, 3 relays, CO, O2 and Fault. All relays are programmable latching or non-latching, dry DPDT, 2 amps (resistive load only) at 110 VAC
Sensor: Electrochemical for both CO and oxygen
Inlet Pressure: Maximum 250 psi; regulator supplied
Size & Wt.: 10.46" H x 8.44"W x 5.75"D; 9 lbs.
Audio Alarm: 90 dB at 2 feet

Air Filtration Systems for Supplied Air Respirators
AFS-50 AFS-50 on optional plate with ISA-RAL-M
Features:
  • Designed for assuring Grade D breathing air, when equipped with optional CO / O2 monitor
  • Includes 4 outlets for connecting with supplied air respirators
  • Two-stage prefilter / coalescer removes oil, water and solid particles
  • Adsorber removes unpleasant odor and taste

Specifications:

Inlet pressure: Maximum 150 psi
Total air capacity: Maximum 50 CFM
Outlet Connections: Supplied with 4 quick disconnects (Hansen series 1000 compatible) for connecting respirators
Inlet Port: 1/2" NPT, female
Size: 12"W x 15"H x 5"D (AFS-50 only)
Weight: 10 lbs. (AFS-50 only)

Can be supplied in the following configurations:

In optional transit case:
High impact ABS construction, 19" x 15" x 6", 8 lbs.

On optional wall mount plate:
Painted steel construction, 21"W x 17"H, 13 lbs.

With optional CO / O2 Monitor

AFS-50 System and Options
Description Part No.
AFS-50 Air Filtration System. Supplied with mounting brackets 03462-001
Optional Plate, wall mounting. For ISA-RAL-M, ISA-200 Series CO or CO / O2 monitor and AFS-50 03262-002
Optional Case. Holds AFS-50 and CO-RAL, 9 VDC, CO Monitor during transit and use 03462-003

MX-52 Enguard Gas Detection System Controller
19" Rack or Panel Mount gas detection system controller. This instrument control panel provides loop power and can monitor up to 16, 24-VDC, 4-20mA sensor/transmitters. The controller can be connected to any combination of 2-wire or 3-wire combustible gas, oxygen or toxic gas sensor/transmitters. A complete 16 channel system utilizes eight 2-channel circuit boards. Each channel, from 1 to 16 can be programmed to be either active (on) or inactive (off). A system with only one or two control cards can be purchased initially, and expanded later by adding plug-in channel cards.
  • Independent channel operation
  • Audio and visual alarms
  • Microprocessor based electronics
  • Utilizes SMC technology
  • Programmable in English, French, German or Spanish
  • Digital system display
  • 3 alarms per channel
  • Programmable alarms and relays
  • 4-20 mA and serial output
  • Fault alarm and relay
  • Provides 24 VDC loop power
  • RFI and EMI suppression
  • CE mark
Specifications
Channels 1 - 16 independent channels
Mounting 19" Rack or Panel mount. Fits 19" cabinet with 5-1/4" high panel space
Display Fluorescent 2 lines, 16 characters, fixed or scrolling
Power 110 VAC, 220 VAC or 24 VDC
Inputs 4-20 mA, 24 VDC, 2-wire or 3-wire sensor/transmitters
Loop Power 24 VDC provided
Outputs 4-20 mA per channel, and system RS485
Alarm Levels 3 alarm levels per channel
Visual Indicators,
per channel
Active Channel: Green LED
Gas Alarms: 3 Red LEDs
Fault: Yellow LED
Audio Alarm Horn activated by 1st gas alarm or fault
Relays 2A, 250 VAC/30VDC, 2 per channel (1st and 2nd alarm)
1 system 3rd gas alarm
1 system fault relay
Languages System programmable in English, French, German or Spanish
Programming
Relays/Alarms
Relays can be programmed to be latching or non-latching. Alarm relays 1 and 2 can be programmed for special fan control sequence. Relays 1 and 2 have a programmable time delay feature. System alarm relay 3 is programmable for time delay or average value activation
Sensor/Transmitters Sensor/transmitters are available for a wide range of toxic and combustible gases. A partial list follows:

AsH3, B2H6, Cl2, ClO2, CO, CO2, COCl2, ETO, HCl, HCN, HF, H2, H2S, NH3, NO, NO2, N2H4, O2, O3, PH3, SiH4, SO2, VCM, VOCs, F2, SiH2Cl2, HBr, BCl3, SF4, WF6, H2Se, Si2H6, Br2, I2, NF3, SF6, TEOS, HCHO

Sensor/transmitters are also available for organic solvents in ppm or % LEL, and combustible hydrocarbon gases in 0 - 100% LEL

MX-Series Enguard — Wall Mounted Gas Detection Controllers

MX-42A

MX-48

These instrument control modules can be used to power and monitor a variety of 24 VDC, 4-20 mA, sensor/transmitters. They can be connected to any combination of up to four (MX-42A) or eight (MX-48) oxygen, toxic or combustible gas sensor/transmitters.
  • Independent channel operation
  • Audio and visual alarms
  • Microprocessor based electronics
  • Utilizes SMC technology
  • Programmable alarms and relays
  • 3 alarms per channel
  • Digital system display
  • 4-20 mA output per channel
  • Fault alarm and relay
  • Alarm status LEDs
  • Provides 24 VDC loop power
  • Simple wall mount installation
  • RFI and EMI suppression
  • CE mark

Specifications for MX-42A and MX-48 Wallmount Controllers
MX-42A MX-48
Channels 1 - 4 Independent channels Channels 1 - 8 Independent channels
Enclosure Shielded PVC enclosure Enclosure Painted steel enclosure
Rating IP54 Ingress rating Rating IP65 Ingress rating
Display LCD Display Fluorescent, 2 lines, 16 characters, fixed or scrolling
Weight 11 lbs (4.9 kg) Weight 24 lbs (11 kg)
Size 11-3/4"H x 13-1/2"Wx 4-1/4"D (300 x 340 x 107 mm) Size 13-1/2"H x 19-1/2"W x 3-1/2"D (340 x 500 x 89 mm)
Common Specifications
Inputs 4-20 mA, 24 VDC, 2 or 3 wire sensor/transmitter
Loop Power 24 VDC provided
Outputs 4-20 mA per channel
Power 110 VAC, 220 VAC or 24 VDC
Audio Alarm Horn activated by 1st gas alarm, or fault
Relays 2A, 250 VAC/30VDC, 2 per channel (1st & 2nd alarm)
1 system 3rd gas alarm
1 system fault relay
Programming, relays / alarms:
Relays can be programmed to be latching or non-latching. Alarm relays 1 and 2 can be programmed for special fan control time sequence. Relays 1 and 2 have a programmable time delay feature. System alarm relay 3 is programmable for time delay or average value activation.

Enguard 97D
Stand-alone controller with integral toxic gas sensor or optional remote sensor with cable. The Enguard 97D system is a self-contained single point gas monitor with an inegral sensor. As an option, the instrument can be supplied with a remote sensor on a six foot cable. This unique system includes a digital display, LED visual alarms, an audio alarm, and comes standard with an AC line cord. The unit is provided with three factory programmed alarm points.
  • Electrochemical sensors available for oxygen, hydrogen and other toxic gases
  • Audio and visual alarms
  • Standard with AC line cord
  • Power: 85 - 265 VAC, 24 VDC
  • 4-20 mA output signal
  • LCD display of gas concentration in ppm or % by volume for oxygen
  • Three factory programmable alarm points
  • 5 VDC TTL outputs available for auxilliary alarm activation from three factory set points
  • Pushbutton calibration
  • IP65, polycarbonate enclosure
  • One alarm relay, user selectable (alarm 1, 2 or 3)
  • Integral or optional remote sensor

Specifications for Enguard 97D
Controller Specifications
Size 8.5"H x 7.6"W x 5"D (220 x 200 x 130 mm)
Weight 3 lbs. (1.36 kg)
Enclosure IP65, polycarbonate, wall mount
Input Power 85 - 265 VAC or 24 VDC
Outputs 4-20 mA; 5 VDC TTL outputs available for auxiliary alarm activation from three factory set points
Relay Single 2 amp 120 VAC relay, at one alarm level in conjunction with horn. User selectable from three factory set alarm levels
Sensor Options Enguard 97D comes standard with an integral sensor. As an option, the sensor can be supplied with a remote sensor housing and a six foot cable. Remote sensor is approx. 5" long x 1-3/4" diameter
Monitors available for following gases: (table gives typical range and display resolution in ppm)
Gas Range Display
H2S 0 - 100 1
H2 0 - 2000 1
SO2 0 - 30 0.1
HCl 0 - 30 0.1
F2 0 - 1 0.01
COCl2 0 - 1 0.01
SiH4 0 - 30 0.1
NO2 0 - 30 0.1
AsH3 0 - 1 0.01
ETO 0 - 30 0.1
CO 0 - 500 1
HCN 0 - 30 0.1
NO 0 - 100 1
HF 0 - 10 0.1
NH3 0 - 100 1
PH3 0 - 1 0.01
Cl2 0 - 10 0.1
O3 0 - 1 0.01
ClO2 0 - 1 0.01
O2 0 - 30.0% 0.1%
Calibration kits are available for all gases shown above

EX-5150-MOS — Sensor/Transmitter for PPM Hydrocarbons & Organic Solvents
A MOS sensor consists of a heated mixed metal oxide element that decreases in resistance in the presence of many gases and vapors. These sensors are broad range in their response characteristics. Different types of MOS sensors are available which can be optimized for a particular gas, but they are inherently non-specific.
The MOS sensor can provide monitoring capability similar to that of the classic catalytic bead or hot wire sensor, but it can be calibrated for either %LEL or ppm detection levels of a wide range of hydrocarbons and organic solvents. The MOS sensor can also be used for detecting certain common toxic gases, including NH3, CO, H2S, etc.
MOS sensors operate at a lower temperature than catalytic bead/hot-wire sensors, which makes them less prone to poisoning. The MOS sensor is therefore the sensor of choice in applications where, for example, lead, phosphates or sulfur containing compounds are present. Silicones, which are used in a wide range of oils, lubricants, adhesives and many other products can poison hot wire sensors and also influence the performance of MOS sensors under certain conditions. Applications for monitoring of hydrogen and hydrocarbon gases where silicones are present in the environment should be discussed with ENMET.
  • Solid state sensor
  • Explosion proof design
  • NEMA-4X enclosure
  • 4-20 mA output
  • Liquid crystal display
  • Non-intrusive calibration

Examples of some typical calibrations with EX-5150-MOS
Toxic Combustible
Gas/Vapor Range Gas/Vapor Range
Acetone 2000 ppm Acetone 100% LEL
Ammonia 300 ppm Isopropyl Alcohol 100% LEL
Methyl Alcohol 400 ppm Propane 100% LEL
Methyl Chloride 200 ppm Vinyl Acetate 100% LEL
Toluene 400 ppm Toluene 100% LEL
MEK 400 ppm Gasoline 100% LEL
Styrene 100 ppm Butane 100% LEL
R-134A 1000 ppm Methane 100% LEL
HFE-7100 100 ppm Hydrogen 100% LEL
Methylene Chloride 200 ppm Hexane 100% LEL
Xylene 400 ppm Xylene 100% LEL
In general, the EX-5150-MOS can be calibrated for combustible hydrocarbons, halogenated hydrocarbons, jet fuels, refrigerants, organic solvents, esters, ethers, alcohols, ketones, CO, H2S and other compounds and mixtures.

Specifications for EX-5150-MOS
Voltage 24 VDC, loop powered
Output 4-20 mA
Installation 3-wire, typically 16 to 18 AWG, depending upon distance
Connection 1/2" NPT, conduit
Display 8-character, single line, backlit LCD
Alarm Indicators LEDs
Menu/Calibration Magnet actuated switches
Sensor MOS (metal oxide semiconductor)
Ordering Information
Part Number Description
10014-008 EX-5150-MOS, HV (calibration dependent)
10014-009 EX-5150-MOS, LV (calibration dependent)
50030-001 Replacement magnet
80003-097 Instruction manual
73152-000 Optional sealing fitting
05006-001 Optional relay PC board
For replacement sensors, check manual
03032-830 Sensor HV, fluorocarbons/refrigerants
03032-832 Sensor HV, fluorocarbons/refrigerants
03033-018 Sensor HV, fluorocarbons/refrigerants
03033-019 Sensor HV, NH3
03033-109 Sensor LV
03033-812 Sensor HV
03033-813 Sensor HV
Calibration Equipment
03700-001 Calibration adapter, humidifier and regulator for 17 liter gas cylinders, for gases other than toluene and ammonia
03700-005 Calibration adapter, humidifier and regulator for 17 liter gas cylinders, toluene
03700-009 Calibration adapter, humidifier and regulator for 58 liter gas cylinders, ammonia (see part # 03230-300, 300/200 ppm)
73083-000 Case - holds calibration hardware and up to two 34 liter or two 17 liter gas cylinders
73083-002 Case - holds calibration hardware and up to four 17 liter gas cylinders or two 58 liter gas cylinders
Gas Samplers and Controllers
Controllers: MX-32, MX-42A, MX-48 and MX-52 controllers are available, 1 to 16 channels
Toxic gas sensor/transmitter: SDS-XXXX-97D series sensor/transmitters are available for monitoring oxygen and a wide range of toxic gases
Combustible sensor/transmitter: the EX-5100 utilizes a pellistor/catalytic sensor for % LEL hydrocarbons
Infrared sensor/transmitter: the IR-6000 is an infrared based sensor/transmitter for % LEL hydrocarbons

WSP home Products Suppliers
Gas Detection Enmet Page 1 Enmet Page 3