For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
38XR-A
|
![]() |
37XR-A
|
![]() |
34XR-A
|
![]() |
33XR-A
|
30XR-A
|
| Features | 30XR-A | 33XR-A | 34XR-A | 37XR-A | 38XR-A |
| DC Voltage | 200.0mV, 2.000, 20.00, 200.0, 600V | 400.0m, 4.000, 40.00, 400.0, 1000V | 1000m, 10.00, 100.0, 1000V | ||
| AC Voltage | 200.0mV, 2.000, 20.00, 200.0, 600V | 400.0m, 4.000, 40.00, 400.0, 750V | 1000m, 10.00, 100.0, 750V | ||
| DC Current | 200.0µ, 2.000m, 20.00m, 200.0m, 10A | 400.0µ, 4.000m, 40.00m, 300.0m, 10.00A | 100.0µ, 1000µ, 10.00m, 100.0m, 400.0m, 10.00A | ||
| AC Current | 200.0µ, 2.000m, 20.00m, 200.0m, 10A | 400.0µ, 4.000m, 40.00m, 300.0m, 10.00A | 100.0µ, 1000µ, 10.00m, 100.0m, 400.0m, 10.00A | ||
| Resistance | 200.0 ohm, 2.000k, 20.00k, 200.0k, 2.000M, 20.00M | 400.0, 40.00k, 4.000M | 400.0, 4.000k, 40.00k, 400.0k, 4.000M, 40.00M | 1000.0, 10.000k, 100.00k, 1000.0k, 10.00M, 40.00M | |
| Continuity | Yes | ||||
| Diode | Yes | ||||
| Non-contact Voltage | Yes | N/A | |||
| Capacitance | N/A | 4.000µF, 40.00µF, 400.0µF, 4000µF | 40.00n, 400.0n, 4.000µ, 40.00µ, 400.0µF | ||
Frequency |
N/A | 4.000k, 40.00k, 400.0k, 1MHz | 100.00, 1.0000k, 10.000k, 100.00k, 1.0000M, 10.000MHz | ||
| Temperature | N/A | 1000ºC | N/A | 1300ºC | |
| Duty Cycle | N/A | N/A | 0.0 to 90.0% | 0.00 to 90.00% | |
| Logic Test | N/A | Yes | N/A | ||
| Inductance | N/A | 40 H | N/A | ||
| dBm | N/A | -13dBm to +50dBm | |||
| Battery Test | 1.5V, 9V | N/A | |||
![]() |
| The three XP Series digital multimeters are full featured, compact in size with two unique extras: VolTect™ and our exclusive Magne=Grip holster. Every XP DMM includes select features that make your testing safer, easier and more efficient whether it be in field service, electronic repair, electrical or HVAC applications. Delivering the best performance in a compact instrument, the XP series is the right choice for your work. |
35XP-A
|
15XP-A
|
5XP-A
|
| Features | 5XP-A | 15XP-A | 35XP-A |
| DC Voltage | 200.0mV, 2.000, 20.00, 200.0, 1000V | 400.0m, 4.000, 40.00, 400.0, 1000V | |
| AC Voltage | 200.0mV, 2.000, 20.00, 200.0, 750V | 400.0m, 4.000, 40.00, 400.0, 750V | |
| AC/DC Current | 200.0µ, 2.000m, 20.00m, 200.0mA | 200.0µ, 2.000m, 20.00m, 200.0m, 2A | 400.0µA, 4.000µA, 40.00mA, 400.0mA, 2A |
| Resistance | 200.0ohm, 2.000k, 20.00k, 200.0k, 2.000M, 20.00Mohm | 200.0ohm, 2.000k, 20.00k, 200.0k, 2.000M, 20.00M, 2000Mohm | 400.0, 4.000k, 40.00k, 400.0k, 4.000M, 40.00Mohm |
| Continuity Beeper | Yes | ||
| Non-Contact Volts | 70 V to 600 VAC (50 - 60 Hz) | ||
| Capacitance | N/A | 4.000n, 40.00n, 400.0n, 4.000µ, 40.00µ, 400.0µ, 4.000mF | |
| Frequency | N/A | 4.000k, 40.00k, 400.0k, 1MHz | |
| Temperature | N/A | -20ºC to 1000ºC |
|
| Logic Test | N/A | TTL, 20MHz | N/A |
| Battery Test | 1.5V, 9V | N/A | |
| Available on all XP series meters: Magne-Grip holster with magnetic hanging strap frees both hands for work. VolTect™ non-contact voltage detection lets you instantly detect AC line voltages. | |||
![]() |
Model AU92 is a full featured multimeter that has additional measurement features for automotive servicing. It offers a built-in thermometer and tests engine RPM and dwell as well as standard multimeter features of voltage, current, resistance and continuity.
|
![]() |
|||
AM-220 & AM-240
|
|||
![]() |
|||
DM73C
|
|||
| Features | AM-220 | AM-240 | DM73C |
| Voltage AC | 400m, 4.000, 40.00, 400.0, 600 V | 3.400, 34.00, 340.0, 600 V | |
| Voltage DC | 340.0m, 3.400, 34.00340.0, 600V | ||
| AC/DC Current | 400.0µ, 4000µ, 40.00m, 400.0m, 4.000, 10.00A | N/A | |
| Resistance | 400.0, 4.000k, 40.00k, 400.0k, 4.000M, 40.00Megohms | 340.0, 3.400k, 34.00k, 340.0k, 3.400M, 34.00 Meg ohms | |
| Capacitance | 40.00n, 400.0n, 4.000µ, 40.00µ, 400.0µ 4000µF | N/A | |
| Frequency | 10.00, 100.0, 1000, 10.00k, 100.0k, 1000k, 10MHz | N/A | |
| Diode | N/A | Yes | |
| Continuity | Yes | ||
Duty Cycle |
0.1% - 99.9% | N/A | |
| Temperature | N/A | -50ºC to 750ºC | N/A |
| Three multimeters with innovative features in an ultra-compact size. Simplified interface with easy one-touch button control, oversize digital display screens. Progressive design with two remarkable features called VolTect™ and AutoTect™. VolTect™ feature is a built-in AC voltage detector. AutoTect™ feature is a function that automatically selects the meter to display between AC volts, DC volts or resistance depending upon what the meter senses at the probe tips (PM55A, PM53A) Compact size offers a meter that is only .95 cm thick and weighs less than 85 g. Low Z input impedance to eliminate ghost voltages. Hi Z input impedance for electronic circuitry (PM55A) |
|||
![]() |
|||
PM55A
|
|||
![]() |
|||
PM53A
|
|||
PM51A (Not shown)
|
|||
| Features | PM51A | PM53A | PM55A |
| Voltage AC/DC | 400.0m, 4.000, 40.00, 400.0, 600V | 6.000, 60.00, 450.0V | 6.000, 60.00, 600V |
| Resistance | 400.0, 4.000k, 40.00k, 400.0k, 4.000M, 40.00Mohms | 600.0, 6.000k, 60.00k, 600.0k, 6.000Mohms | |
| AC/DC µA Current | N/A | 400.0µA, 2000µA | |
| Frequency | 400Hz, 4kHz, 40kHz, 400kHz, 1MHz | 100Kz, 1kHz and 10kHz | 10.00Hz - 30.00kHz |
| Capacitance | 500.0n, 5.000µ, 50.00µ, 500.0µ, 3000µF | 100.0n, 1000n, 10.00µ, 100.0µF | |
| Non-Contact Voltage | N/A | Yes | |
| Diode Test | 0.25mA | N/A | 0.48mA |
![]() |
||||
| Turn to this selection of general purpose testers when you need a choice between analog, compact, digital or unique sizes. These meters are great for the everyday user or for those occasional measurements you need to make | ||||
DM7C
|
||||
DM9C
|
||||
DM78B
|
||||
AM8C
|
||||
| Features | DM7C | DM9C | DM78B | AM8B |
| DC Voltage | 2.000, 20.0, 200.0, 600V | 400.0m, 4.000, 40.00, 400.0, 600V | 320.0m, 3.200, 32.00, 320.0, 600V | 2.5, 10, 50, 150, 300V |
| AC Voltage | 200.0, 600V | 400.0m, 4.000, 40.00, 400.0, 600V | 3.200, 32.00, 320.0, 600V | 50, 150, 300V |
| DC Current | 200 mA | 40.00, 400m, 10.00A | N/A | 0.5, 10, 250 mA |
| AC Current | N/A | 40.00, 400m, 10.00A | N/A | N/A |
| Resistance | 2000, 20.00k, 200.0k, 2MOhms | 400.0, 4.000k, 40.00k, 400.0k, 4.000M, 40.00MΩ | 320.0, 3.200k, 32.00k, 320.0k, 3.200M, 32.00MOhms | 5kohm, 500kohm |
| Diode Test | Yes | N/A | ||
| Continuity | Yes | N/A | ||
| Battery Test | 1.5V, 9V | N/A | 1.5V, 9V | |
![]() |
![]() |
![]() |
| AM-120 Multimeter | AM-130 Multimeter | AM-150 Multimeter |
| • True TRMS • Optical isolated PC interface capability • Auto and manual ranging • Auto power off • Data hold • Peak Hold • Auto & Manual Ranging • Backlight display • Large, easy to read LCD display • Auto compensation of the test leads resistance • Diode test • Audible continuity • Alligator clips are not supplied with this product. |
||
| Features | AM-120 | AM-130 | AM-150 | Accuracy |
| AC Voltage | 50.00 / 500.0 mV / 5.000 / 50.00 / 500.0 / 1000V | ± (0.5% Rdg + 3 LSD) @ 50 and 60Hz | ||
| DC Voltage | 50.00 / 500.0 mV / 5.000 / 50.00 / 500.0 / 1000V | ± (0.08% Rdg + 2 LSD) @ 5V to 1000V ranges | ||
| Resistance | 50.00 / 500.0 Ω / 5.000 / 50.00 / 500.0 kΩ / 5.000 / 50.00 MΩ | ± (0.2% Rdg + 6 LSD) @ 50Ohms to 500 kOhms ranges | ||
| AC/DC Current | 500.0 / 5000 uA / 50.00 / 500.0 mA / 5.000 / 10.00 A | DC: ± (0.2% Rdg + 4 LSD) AC: ± (1.0% Rdg + 4 LSD) | ||
| Frequency | 6Hz to 125 kHz for all setups except: 6Hz to 1kHz for 500V and 1000V ranges 6Hz to 20kHz for 50V range |
± (0.01% Rdg + 2 LSD) | ||
| Capacitance | 50.00 / 500.0 nF 5.000 / 50.00 / 500.0 / 9999µF |
± (2.0% Rdg + 3 LSD) @ 50 nF to 50uF ranges | ||
| Temperature | N/A | -50 C to 1000 C | ± (0.3% Rdg + 5 LSD) | |
| Data Recording | N/A | Records PEAK, MAX, MIN, MAX-MIN |
5400 Points | |
| Relative Zero Mode | N/A | Yes | N/A | |
![]() |
| These "top of the line" digital multimeters are affordable without sacrificing an array of features and functions. From true RMS to PC Connectivity Amprobe’s Precision DMMs excel in the professional environment. • True RMS (TRMS) • Optical isolated PC interface capability • MAX, MIN MAX-MIN recording • Peak hold • Auto and manual ranging • Intelligent auto power off • Data hold • Relative zero mode • Audible and visual warning against improper plug-in • DC Loop Current 4-20mA • dBm reading with 20 selectable impedance values • Backlight display • Large, easy to read LCD display • Diode Test • 4-20mA DC loop current • Audible continuity • Safety: CAT III 1000V, CAT IV 600V |
| Features | AM-140 | AM-160 | Accuracy |
| AC Voltage | 500.00 mV 5.0000 / 50.000 / 500.00 / 1000.0 V |
AM-140: ± (0.08% Rdg + 60 LSD) @ 45 to 300 Hz AM-160: ± (0.08% Rdg + 20 LSD) @ 45 to 300 Hz |
|
| DC Voltage | 500.00 mV 5.0000 / 50.000 / 500.00 / 1000.0 V |
AM-140: ± (0.10% Rdg + 2 LSD) AM-160: ± (0.05% Rdg + 2 LSD) |
|
| Resistance | 500.00 Ohms 5.0000 / 50.000 / 500.00 kOhms 5.0000 / 50.00 0MOhms |
AM-140: ± (0.10% Rdg + 6 LSD) @ 500 Ohms to 500 kOhms ranges AM-160: ± (0.07% Rdg + 2 LSD) @ 500 Ohms to 500 kOhms ranges |
|
| AC Current | 500.00 / 5000.0 uA 50.000 / 500.00 mA 5.0000 / 10.000 A |
AM-140: ± (1.0% Rdg + 40 LSD) @ 50 and 60 Hz AM-160: ± (0.5% Rdg + 50 LSD) @ 50 and 60 Hz |
|
| DC Current | 500.00 / 5000.0 uA 50.000 / 500.00 mA 5.0000 / 10.000 A |
± (0.5% Rdg + 20 LSD) | |
| Frequency | 5.0000 Hz to 200.000kHz | ± (0.002% Rdg + 4 LSD) | |
| Capacitance | 50.00 / 500.0 nF 5.000 / 50.00 / 500.0 / 9999uF |
± (2.0% Rdg + 3 LSD) @ 50 nF to 50uF ranges | |
| Temperature | N/A | Dual thermocouple -58 F to 1832 F -50 C to 1000 C |
± (0.3% Rdg + 2 F) ± (0.3% Rdg + 1 C) |
| Duty Cycle | 0.1% to 99.99% | ± (3 LSD / kHz + 3 LSD) | |
| Optional Accessories | Part Number |
| 3000A AC Flexible Clamp-on Attachment | ACF-3000 AK |
| 1000A TRMS AC/DC Clamp-on Attachment | A-1000 |
| 600A AC/DC Clamp-on Attachment | CT-600 AC/DC |
| 400A AC Clamp-on Attachment | A400 |
| Milli-Amps to 30A AC/DC Clamp-on Attachment | CT-30 |
| Dual input Thermocouple adapter with two thermocouples -50ºF to 600ºF (AM-130TRMS and AM-150TRMS Only) | DKTA-620 and two of TPK-56 |
| Single Input Thermocouple Temperature Attachment (Recommended for AM-120 TRMS) | TMA-K |
| Alligator Clips (For test leads) | VRC-320 |
| PC Interface kit (PC connection cable with software) | RS-232 KIT1 |
| USB to RS-232 Adapter | RS-USB |
| Carrying Case | CC-ACDC |
| Replacement Parts (supplied with product) | Part Number |
| Thermocouple (AM-130TRMS and AM-150TRMS Only) | TPK-59 |
| Test leads with set of alligator clips (alligator clips are not supplied with product) | MTL-90B |
| Fuse 0.63A/500V IR 200kA for mA/uA terminal (AM-120 TRMS and AM-130 TRMS) | FA-6x32/.63 |
| Fuse 12.5A/500V IR 20kA for Amp terminal (AM-120 TRMS and AM-130 TRMS) | FA-12.5A/500V |
| Fuse 1A/1000V IR 10kA for mA/uA terminal (AM-150 TRMS) | FA-1A/1000V |
| Fuse 15A/1000V IR 10KA or 11A/1000V IR 20kA for Amp terminal (AM-150 TRMS) | FA-15A/1000V |
![]() |
![]() |
|
| HD110C | HD160C | |
Choose from two heavy duty digital multimeters that are designed for rugged use with extra features that make them better suited for field work. They offer extensive protection that will resist harsh and even abusive environments. Thicker case walls made from specialty plastics resistant to grease and chemical spills. They include rubber holsters, sealed and gasketed openings, shock dampened mountings, extensive fusing and superior protection from overloads.
|
||
HD110C
|
||
HD160C
|
||
| Features | HD110C | HD160C |
| DC Voltage | 1000.0m, 10.000, 100.00, 1500.0V | |
| AC Voltage | 200.0m, 2,000, 20.00, 200.0, 1000V | 1000.0m, 10.000, 100.00, 1000.0V |
| AC/DC Current | 200.0µ, 2.000m, 20.00m, 200.0m, 2A | 100.00µ, 1000.0µ, 10.000m, 100.00m, 400.0m, 2.000A |
| Resistance | 200.0Ω, 2.000kΩ, 20.00kΩ, 200.0kΩ, 2.000MΩ, 20.00MΩ | 1000.0Ω, 10.000kΩ, 100.00kΩ, 1000.0kΩ, 10.000MΩ, 40.00µΩ |
| Diode | Yes | N/A |
| Continuity | Yes | |
| Frequency | N/A | 100.00, 1000.0, 10.000k, 100.00k, 1000.0k, 10.000MHz |
| Capacitance | N/A | 40.00µF, 400.0µF, 4.000µF, 40.00µF, 400.0µF |
| Temperature | N/A | -20ºC - 1300ºC |
![]() |
PRM-3 Phase sequence testing is crucial for some of the three phase loads, whenever they need to be connected to the electrical system, improper connection of three phase motors may lead to reverse rotation, and as a result, it may damage equipment powered by a motor. Amprobe's Phase Sequence and Motor Rotation Tester is used to assure proper and safe connection of the electrical equipment on three phase systems
|
![]() |
||
| A user-friendly troubleshooting tester designed to meet most voltage and continuity applications. • Extremely easy to use, no buttons, no setups • Automatically turns ON and OFF • Automatically selects AC Voltage, DC Voltage or Continuity • Indicates seven levels of AC or DC Voltage • Visual continuity indication (LED) • Continuity buzzer • Safety: CAT-III 600V |
||
| Features | VPC-10 | VPC-10N |
| AC Voltage | 24 /120 / 208 / 240/ 277/ 480/ 600 | |
| DC Voltage | 6 / 12 / 24 / 36 / 48 / 110 / 220 | |
| Continuity | 0-85 kOhms | |
| Non-contact voltage detection | No | Yes |
| Optional Accessories | Part Number | |
| Carrying Case | SV-U | |
| Designed for safety and limited troubleshooting without the expense. Fits conveniently in a shirt pocket, tool belt, or pouch. • Detect AC Voltage (100 600V) • Use non-contact method of Voltage testing • Totally insulated, no exposed metal or conductive parts • Check for AC Voltages without necessity of disconnecting the electrical system • Test for AC Voltage cables, circuit breakers, wall sockets, junction boxes, fuses, etc. |
|||
| Features | VP-600 | VP600B | VP-600SB |
| AC Voltage Detection | 100 - 600 V | ||
| Voltage Buzzer | No | Yes | Yes |
| Voltage Shaker | No | No | Yes |
| • Detects AC Voltage (110 600V) • Uses non-contact method of voltage testing • Totally insulated, no exposed metal or conductive parts • Checks for AC Voltages without necessity of disconnecting the electrical system • Tests for AC Voltage cables, circuit breakers, wall sockets, junction boxes, fuses, etc. |
left to right: PY-1, PY-5, K-1 |
| PY-1: AC/DC High Voltage Tester • AC Volts 115/220/277/400 • DC Volts 125/300/400/600 • Automatically indicates voltage of circuit under test • Four neon bulb indicator lamps PY-5: Pen Type AC/DC Voltage Tester K-1: Kwik-I-E Non-Contact Volt & Amp Probe |
left to right: PY-2, PY-3, PY-11 |
| PY-2: 110V AC Receptacle Tester with G.F.C.I. • Tests any standard 110V AC grounded outlet • Detects correct wiring or following faults: open ground, reversed polarity, open hot, open neutral, hot & ground wires reversed, hot on neutral with hot open • Checks the operation of G.F.C.I. protected circuits • UL approved PY-3: 110V AC Receptacle Tester PY-11: Continuity Tester |
| WSP home page | Products page | Suppliers page | |
| Electrical Safety | Amprobe Index | Previous Amprobe Page | Next Amprobe Page |