Amprobe Electrical Page 2

For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

Credit Card Images

DM-III & DM-III Flex Power Quality Recorders
Amprobe's full featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to operate accurately and effectively in today's demanding electrical environments.
  • True RMS (TRMS)
  • Comes as a complete kit, CTs and PC software are included with product
  • Works with single and three phase systems (Y and delta)
  • Detects and records voltage anomalies Sags and Surges
  • Built in scope displays waveforms
  • Records up to 64 parameters (single or three phase) simultaneously
  • Manual and programmable recording start
  • Password protection
  • Selectable fundamental frequency of 50 or 60 Hz
  • Special data compression system and user selectable rates allow recording from several hours to several years
  • Download capabilities, Windoze compatible PC software
  • Line or battery powered
  • Safety: CATIII, 600V Phase to phase, CATIII, 300V Phase to ground, EN 61010-1+A2(1996)

Specifications for DM-III & DM-III Flex Power Quality Recorders
Features DM-III DM-III Flex Basic Accuracy
Supplied Current
Transducer
1000A Standard CT
2" Internal dia. CT
3000A Flexible 7"
internal dia. CT
Input accuracy:
+/-(0.5% rdg + 2 LSD)
AC Current 5 - 1000A (expandable to
3000A with optional flexible CTs)
15 - 3000A (1000A
standard CTs can be used as an option)
AC voltage including
Sags & Surges
0 - 600 V +/-(0.5% rdg + 2 LSD)
Harmonics THD, DC and individual up to 49th +/-(0.5% rdg + 2 LSD) @ DC to 25 harmonics
Power Working (W), Reactive (VAR) and Apparent (VA) +/-(1.0% rdg + 2 LSD)
Energy Working (kWh), Reactive (VARh) and Apparent (VAh) +/-(1.0% rdg + 2 LSD)
Peak Demand KW +/-(1.0% rdg + 2 LSD)
Power Factor 0.00 — 1.00  
Frequency
Measurement
57 to 63.6 Hz at 60 Hz fundamental
47 to 53 Hz at 50 Hz fundamental
+/-(1.0% rdg + 2 LSD)
Phase Sequence 1 - 2 - 3
Co-generation Measures absorbed and generated power and energy
Selectable Fundamental
Frequencies
50 / 60 Hz
Available recording
time
Several hours to several years depending on setup

Accessories & Replacement Parts for DM-III & DM-III Flex
Optional Accessories Part Number
1000A Clamp (supplied with the DM-III) DM-CT-HTA
3000A Flexible CT for recorders marked as the DM-IIIS on a
front label (supplied with the DM-III Flex)
FLEX3
3000A Flexible CT for recorders marked as the DM-III on a
front label
ACF-3000SR
USB-RS-232 Adapter RS-USB
Hard Case CC-DM-III
Replacement Parts Part Number
1000A Clamp (supplied with the DM-III) DM-CT-HTA
3000A Flexible CT for recorders marked as the DM-IIIS on a
front label (supplied with the DM-III Flex)
FLEX3
Soft Carrying case HW1254A
External power supply 12VDC DMT-EXTPS
Test leads and alligator clips (set of 4) KITENERGY3
Special RS-232 Computer Cable C232NG1

CC-DM-III Hard Case
• Hard case for the DM-III and the DM-III Flex
• Protects instrument while it is recording on the jobsite
• Carrying case for the instrument and the accessories ACF-3000 SR Flexible Current Transducer
• Accessory for the DM-III (recorders marked as the DM-III on the front label*) and the MT-2000
• Current measurement from 15A to 3000A for each of the three phases
• Neutral wire current measurement down to milliamps for the DM-III
• Flexible head fits all small conductors and large bus-bars up to 7” in diameter
• Recommended one ACF-3000 SR for single phase system, and three for three phase systems
• Output Sensitivity (AC coupled): 0.333 mV per Amp
• Accuracy: +/- 1 % of range
• Safety: CATIII 600V
FLEX3 3000A Flexible Current Transducer
• Accessory for the DM-III and DM-III Flex (recorders marked as the DM-IIIS
on the front label*)
• Current measurement from 15A to 3000A for each of the three phases
• Neutral wire current measurement down to milliamps
• Flexible head fits all small conductors and large bus-bars up to 7” in diameter
• Recommended one Flex3 for single phase system, and three for three phase systems
• Output Sensitivity (AC coupled): 39.1 uV per Amp
• Accuracy: +/- 1.5% of reading (45 – 65 Hz)
*For recorders marked as the DM-III on the front label use the ACF-3000SR flexible CT.
ACF-3000 SR Flexible Current Transducer
• Accessory for the DM-III (recorders marked as the DM-III on the front label*) and the MT-2000
• Current measurement from 15A to 3000A for each of the three phases
• Neutral wire current measurement down to milliamps for the DM-III
• Flexible head fits all small conductors and large bus-bars up to 7” in diameter
• Recommended one ACF-3000 SR for single phase system, and three for three phase systems
• Output Sensitivity (AC coupled): 0.333 mV per Amp
• Accuracy: +/- 1 % of range
• Safety: CATIII 600V
Optional Accessories Part Number
External Power Supply ACF-3A


DM-II Pro
• Comes as a complete kit, CT’s and PC software are included with product
• Works with single and three phase systems (Y and delta)
• Capable of recording all parameters (single or three phase) simultaneously
• All readings are True RMS (TRMS)
• User selectable rates allow recording from one hour to several months
• Five built-in selectable languages: English, Spanish, French, German and Italian
• Readings and charts can be viewed on the DM-II LCD screen or downloaded to a PC
• Intuitive, very easy to use, Windows compatible PC software
• Line or battery powered

Specifications for DM-II Pro
Features Basic Accuracy
AC Voltage 0 - 600V ±(1.0% Rdg + 3 LSD)
AC Current 1 - 1000A (expandable to 3000A with optional CT's) ±(1.0% Rdg + 3 LSD)
Power Working (W), Reactive (VAR) and Apparent (VA)  
Power Factor 0 - 1
Energy kWh
Peak Demand kW
Fundamental Frequencies 50 / 60 Hz
Available Recording Time 1 hour to several months depending on setup

Optional Accessories Part Number
3000 Amps optional flexible current transducer ACF 3000DM-A
USB to RS-232 Adapter RS-USB

Replacement Parts (supplied with product)
Description Part Number Description Part Number
Test leads and alligator clips (set of 4) DVL-2 Standard RS-232 Computer Cable RS-232
Current Transducer (Black) DM-CT-BKCE Power Cord PC-4
Current Transducer (Yellow) DM-CT-YCE    

ACF 3000DM-A Flexible Current Transducer
• Accessory for the DM-II and the DM-II Pro
• Extends current range to 3000A
• Flexible head fits all, small conductors and large bus-bars up to 7" in diameter
• Supplied with adapters for the DM-II and the DM-II Pro
• Two measurement ranges: • 30A to 300A and • 300A to 3000A
• Recommended one ACF-3000DM-A for single phase system, and three for three phase systems
• Accuracy: ±1% of range @ 77°F (25°C)
• Safety: CATIII 600V
Optional Accessories Part Number
External Power Supply ACF-3A


GP-2 Geotest Ground Resistance & Resistivity Tester
Ensure safety and reliability in ground system applications whether it’s resistance or resistivity, with Amprobe’s capable GP-2
• Measures Earth ground resistance - 3 point (fall of potential) or 2 point tests
• Automatically calculates resistivity - 4 point test
• Automatic voltage measurement prevents false measurements
• Automatically applies three testing frequencies for the most accurate readings
• Test leads, auxiliary electrodes and software are included for complete instrument
• Auto ranging
• 999 internal memory locations to store measurements
• RS-232 download to a personal computer
• Safety: CATIII 250V

Features Range & Resolution Accuracy
Ground Resistance 0-19.99, 199.9, 1999 ohms ± 2% Rdg + 3 LSD
Ground resistivity 0.6- 125.6 ohms
0.125-1.256, 19.99, 199.9 kohms
± 2% Rdg + 3 LSD
AC Voltage 0-500.0 V ± 2% Rdg + 2 LSD

Optional Accessories Part Number
USB to RS-232 Adapter RS-USB
Replacement Parts (supplied with product) Part Number
Carrying case containing: 4 auxiliary electrodes and 4 test leads (banana - alligator clip GP-2CON
Instrument carrying case GP-2CC
Optical serial cable C2001


DGC-1000A Clamp On Ground Resistance Tester
User-friendly and accurate. Think safety first and Amprobe’s DGC 1000 ground resistance tester second.
• Accurate ground resistance measurement from 0.025 to 1500 Ohm
• TRMS current measurement including leakage current
• Accurate readings regardless of power quality in less than 10 seconds
• Continuity beep if the resistance is lower than 40.00 Ohm
• Simple and easy to use, no test leads or auxiliary electrodes necessary

Features Range & Resolution Accuracy
Ground Resistance 0.025 - 0.250, 9.999, 99.99, 199.9, 400.0, 600.0, 1500 ohms ± 2% Rdg + 2 LSD
AC Current 0.200 - 1.000, 10.00, 100.0, 1000 mA and 0.2 - 10.00A ± 2% Rdg + 2 LSD

Replacement Parts (supplied with product) Part Number
Carrying bag CC-ACDC


AMB-25 Digital Megohmmeter - Insulation Resistance Tester
Amprobe AMB-25 Megohmmeter
Quality does not have to be expensive. These affordable megohmmeters still offer a solid range of features designed to meet most insulation test applications.
• Test insulation of wires, cables, transformers and electrical motors
• Come as a complete kit including test leads
• Selectable test voltages up to 1000V
• Programmable timer to perform the Dielectric Absorption Ratio Test
• Sensitive Ohmmeter for checking resistance of motor windings
• Built in voltmeter (AMB-35 only)
• Internal memory (stores 9 readings)
• Fast and easy to use, rugged durable design

Features AMB-25 Accuracy
Insulation resistance with 250, 500 & 1000 VDC test voltages 0 - 4.000 /40.00 / 400.0/ 4000 Mohms ± 3% Rdg ± 5 LSD < 1Gohms
± 5% Rdg ± 5 LSD < 4Gohms
Resistance 0 - 9999ohms 1% Rdg ± 2 LSD
Low Resistance   2% Rdg ± 2 LSD
AC/DC Voltage   ± 2.0% Rdg ± 1 LSD

Replacement Parts (supplied with product) Part Number
Carrying case GP-2CC
Test leads complete set MTL-45


AMB-45 Megatest 1 Digital Megohmmeter - Insulation Resistance Tester
• Tests insulation of wires, cables, transformers and electrical motors
• Comes as a complete kit including test leads and PC software
• Selectable test voltages up to 1000V
• Programmable timer to perform the Dielectric Absorption Ratio Test
• Sensitive Ohmmeter for checking resistance of motor windings
• Built in voltmeter
• Fast and easy to use, rugged durable design
• Internal memory to store measurements for future reference
• Data download to PC
• Safety CAT III 600V

Features Range & Resolution Accuracy
Insulation resistance with
250, 500 & 1000 VDC test voltages
0 - 4.000 /40.00 / 400.0/ 4000 Mohms ± 3% Rdg ± 5 LSD < 2Gohms
± 5% Rdg ± 5 LSD < 4Gohms
Low Resistance 0 - 400.0/ 4000 Mohms 1% Rdg ± 5 LSD
AC/DC Voltage 0.1 - 600.0V ± 1.5% Rdg ± 5 LSD

Replacement Parts (supplied with product) Part Number
Carrying case GP-2CC
Special download cable RS-JACK
Test leads complete set MTL-45


AMB-6D Megatest 1000 Digital Megohmmeter Insulation Resistance Tester
Amprobe’s AMB-6D’s full suite of features translate into robust functionality. Designed for the pros who value excellence.
• Tests insulation of wires, cables, transformers and electrical motors
• Comes as a complete kit including test leads and PC software
• Selectable test voltages up to 1000V
• Programmable timer to perform the Dielectric Absorption Ratio Test
• Sensitive Ohmmeter for checking resistance of motor windings
• Selectable polarization of ohmmeter for checking grounding continuity
• Automatic voltmeter warns against hazardous energized systems
• Fast and easy to use, rugged durable design
• Internal memory to store measurements for future reference
• Data download to PC
• Safety CAT III 250V

Features Range & Resolution Accuracy
Insulation resistance with 50 VDC test voltage 0.01-19.99, 49.9, 99.9M ohms ± 2% Rdg + 2 LSD @ 0.01-49.9Mohms
Insulation resistance with 100 VDC test voltage 0.01-19.99, 99.9, 199.9M ohms ± 2% Rdg + 2 LSD @ 0.01-99.9Mohms
Insulation resistance with 250 VDC test voltage 0.01-19.99, 199.9, 249, 499 M ohms ± 2% Rdg + 2 LSD @ 0.01-249Mohms
Insulation resistance with 500 VDC test voltage 0.01-19.99, 199.9, 499, 999 M ohms ± 2% Rdg + 2 LSD @ 0.01-499Mohms
Insulation resistance with 1000 VDC test voltage 0.01-19.99, 199.9, 999, 1999 M ohms ± 2% Rdg + 2 LSD @ 0.01-999Mohms
Low Resistance (without timer) 0.01-19.99, 99.9 ohms ± 2% Rdg + 2 LSD @ 0.01-99.9ohms
Low Resistance (with timer) 0.01-9.99 ohms ± 2% Rdg + 2 LSD @ 0.01-9.9ohms

Optional Accessories Part Number
USB to RS-232 Adapter RS-USB
Replacement Parts (supplied with product) Part Number
Carrying case GP-2CC
Special download cable C2001
Test leads set (complete set of 3) MT1-LEADS


AMB-5KVD Megatest 5000 — 5000V Digital Megohmmeter Insulation Resistance Tester
Rugged design for 5000 Volt applications but delicate features to ensure proper testing and recording of insulation measurements.
• Tests insulation of wires, cables, transformers, electrical motors and generators
• Comes as a complete kit including test leads and PC software
• Built in automatic voltmeter up to 5000V warns against hazardous energized systems
• Programmable setups of test voltages and timers
• Performs the dielectric absorption ratio test
• One testing instrument for low and high voltage systems
• Internal memory, measurements can be stored for future reference
• Data download to PC
• Rugged, durable case

Features Range & Resolution Accuracy
Testing Voltages 100V to 5000V with
25V increments
 
Resistance 100K ohms - 500G ohms ± 5% Rdg + 1 LSD @ 500K ohms -
100G ohms and 500V-5000V
Automatic
Voltmeter
0 - 5000V ± 10% Rdg + 10 LSD @ 0-500V,
± 10% Rdg + 5 LSD @ 500-5000V
Configuration
memory
20 programmable
setup configurations
 
Internal memory 200 measurements

Optional Accessories Part Number
USB to RS-232 Adapter RS-USB
Replacement Parts (supplied with product) Part Number
Carrying case MT5-CC
Special download cable C232NG1
Test leads set (complete set of 3) MT5-LEADS


AMB-5KV 5000V Digital Megohmmeter Insulation Resistance Tester
Analog alternative to the AMB-5KVD. You lose the PC interface but maintain reliable functions and features to get the job done.
• Tests insulation of wires, cables, transformers, electrical motors and generators
• Test voltages 500, 1000, 2500, 5000 VDC
• Measuring range 500K thru 500G ohms
• Built-in voltmeter 0 – 600Volts AC/DC (Accuracy: ± 2% of full scale)
• Lock feature applies testing voltage continuously for Dielectric Absorption Ratio Test
• Automatic discharge of equipment capacitance for operator safety

Replacement Parts (supplied with product) Part Number
Test Leads MTL-5KV


AMB-2 & AMB-3 — Analog Megohmmeter - Insulation Testers
Amprobe Analog Megohmmeters
Left to right: AMB-2, AMB-3

• Tests insulation of wires, cables, transformers and electrical motors
• Battery powered
• Helps cut unscheduled downtime and reduce shock hazards
• Sensitive Ohmmeter for checking resistance of motor windings (AMB-1A and AMB-2)
• Built in voltmeter
• Battery OK test
• Mirror scale
• Automatic discharge of equipment capacitance for safe removal of test leads

Features AMB-1A AMB-2 AMB-3 Accuracy
Insulation resistance with
250 VDC test voltage
N/A 0-50 M ohms N/A ± 5% Rdg @
(0.1 - 10 M ohms)
Insulation resistance with
500 VDC test voltage
0-100M ohms 0-1000 M ohms ± 10% Rdg @
(> 10 M ohms)
Voltmeter 0-600V AC/DC 0-600V AC ± 1.5% Rdg + 3 LSD
Low resistance 0-100 ohms N/A ± 3% Rdg

Replacement Parts (supplied with product) Part Numbers
Test leads for AMB-1A and AMB-2 MTL-6
Adaptor clips for AMB-1A and AMB-2 MTC-3
Fuse (1Amp fast blow) for AMB-1A and AMB-2 8AG361
Test leads with set of alligator clips for AMB-3 MTL-90B


AMC-2, AMC-3, AMC-4 Hand Cranked Megohmmeters
• Tests insulation of wires, cables, transformers and electrical motors
• The test voltage is obtained by means of a hand cranked, constant voltage generator
• Does not require batteries or any external power supply, always ready for use
• Sensitive Ohmmeter for checking resistance of motor windings
• Terminal eliminates effect of any surface leakage that may influence readings
• Light and smooth operating crank
• Rugged cross coil movement
• High impact housing
• Spring loaded terminal connection

Features AMC-2 AMC-3 AMC-4 Accuracy
Insulation resistance with 500 VDC test voltage 0-100 M ohms N/A 100 M ohms ± 5% Rdg @ (0.1 - 50 M ohms)
± 10% Rdg @ (> 50 M ohms)
Insulation resistance with 1000 VDC test voltage N/A 0-500 M ohms 0-500 M ohms ± 5% Rdg @ (0.1 - 100 M ohms)
± 10% Rdg @ (> 200 M ohms)
Low resistance   0-500 M ohms   ± 10% Rdg

Replacement Parts (supplied with product) Part Number
Carrying case for instrument MOC
Carrying case for test leads MOL
Test leads for the AMC instruments (Set of 3) MTL-3

WSP home page Products page Suppliers page