Allegro Page 4 - Sampling Pumps

For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

Credit Card Images

Loading

Selection Guide
Part No. Model M2 Multi-Mold Cassette Impactor PCM .8µ Cassette TEM .45µ & 5.0µ Cassette 37mm Cassette
9805 Diaphragm
9804 A100  
9803 T100  
9803M T100M
9800 D-2      
9801-51 DC        
  Mold Asbestos Lead

Cassette Selection Guide
1 Lead Cassette
This 37 mm MCE cassette is .8µm mixed cellulose ester and is specifically designed for lead sampling. 50 per box.

9804-13

2 TEM Cassette
This 25mm, .45µm + 5.0µm cassette is designed for asbestos final clearance testing. The cassettes incorporate a 2" static conductive extension cowl and meets all applicable standards. 50 per box.

9804-17

3 PCM Cassette
A 25 mm cassette with .8µm pore size for asbestos sampling. The high quality cassette incorporates a 2" cowl and meets stringent quality standards. 50 per box.

9804-16

4 AIROCELL Cassette
These unique cassettes are designed for the rapid collection of particles. Specifically designed for mold spores, pollen and all organic and non-organic particles. This is the cassette of choice for sampling mold by Field Technicians and labs alike.

9804-13: 50 per box
9804-13A: 10 per box

M2 Multi-Mold Cassette
The M2 is a patent-pending two-sided sampling cassette for easier and more efficient use in the field and in the laboratory. This is the first cassett to provide sampling options to field personnel. Each cassette can be used to:
  • Collect two different samples
  • Collect tow identical sample concurrently
  • Collect one sample while user the other side as a control

The M2 cassette is also the very first of its kind for laboratory personnel. It provides one-time preparation for two samples, pre-printed traverse marks on the collection slide for standardized counting and side-by-side comparison of the samples under the microscope.

9804-20 M2 Multi-Mold Cassette, box of 25 cassettes/50 samples
9804-21 M2 Mult-Mold Cassette, box of 5 cassettes/10 samples

Sampling Pumps
T100 Rotary Vane
This lightweight, low maintenance, rotary vane sampler, manufactured by Allegro Industries, has a sampling range of 3 - 20 LPM and is excellent for use for sampling asbestos (25 mm cassettes), lead (37 mm cassettes) and mold (Air-O-Cell cassettes). This sampler is the best value in the market today, meets OSHA and AHERA standards and comes complete with adjustable aluminum tripod, six feet of vinyl tubing, inline filters, muffler jars, feet, handle and built in switch. Weight: 9.7 lbs.

9803: T100 Sampling pump with stand
9803-88: T100 Sampling pump without stand

T100M Rotary Vane
This upgraded version of the T100 Sampling Pump (rotary vane) is manufactured by Allegro Industries, and incorporates all the features of the T100 with the addition of a built-in adjustable 5 - 50 LPM flowmeter. The sampler is specifically designed to be used for not only asbestos, lead and Air-O-Cell cassettes, but will work with Impactors (adjustable flow range 3-30 LPM). It comes complete with adjustable aluminum tripod, six feet of vinyl tubing, inline filters, muffler jar, feet, handle and built-in switch. Weight: 9.9 lbs.

9803M: T100M Sampling pump with stand
9803-88M: T100M Sampling pump without stand

A100 Rotary Vane
This low maintenance rotary vane pump by Gast Manufacturing meets OSHA and AHERA standards for air sampling. With a sampling range of 3 - 20 LPM, the A100 is excellent for use for sampling asbestos (25 mm cassettes), lead (37 mm cassettes) and mold (Air-O-Cell cassettes). The pump is complete with an aluminum tripod, five feet of vinyl tubing, inline filters, muffler jars, feet, handle and a power cord with switch.
Weight: 11 lbs.

9804: A100 Sampling pump with stand
9804-88: A100 Sampling pump without stand

Sampling Pumps Continued
 
Wall Sampling Adapter
Requiring only a small 3/8" hole in the wall to sample, place the tubing attachment into the wall and the connection is made directly to Air-O-Cell cassette. Completely disposable, ther is no need to clean or worry about cross contamination.

9803-01: Wall Sampling Adapter

D-2 Moldlite Sampler
This lightweight, low maintenance, high efficiency, linear oscillating pump has a sampling range of 3 - 33 lpm. It is excellent for use for sampling mold using all types of mold cassettes, as well as impactors. D-2 is the best value on the market today, having a long life of 35,000 hours of continuous use, with only two moving parts. It is extremely low maintenance, no lubrication is required, and it is very quiet. It comes complete with a 5 - 30 lpm fully adjustable flow meter, tripod, six feet of vinyl tubing, and has a built in handle and switch for added convenience.

9800
D-2 Sampler with stand

9800-88
D-2 Sampler without stand

DC Sampling Pump
This unique DC powered, totally self contained programmable unit is designed specifically to run Air-O-Cell (mold) cassettes. Flow range is 5 - 20 LPM, but it is programmed for 15 LPM operation for use with Air-O-Cell cassettes. Preprogrammed buttons offer convenient sampling times of 1, 2, 5, or 10 minutes. An end-of-sample audio/visual alarm indicates completion of the sample. Ther is easy keypad calibration with the supplied calibration flow meter, as well as a charger included in the kit. The DC powered pump allows for 5 hours of continuous operation. It is small, lightweight, compact and includes an adjustable tripod with a special adapter to hold the DC pump at the breathing air zone. Weight: 1.2 lbs.

9801-51: DC Sampler Kit with stand (battery operated)
9801-50: DC Sampler Kit without stand (battery operated)

Allegro Impactor
A single stage bioaerosol impaction sampler to sample mold and fungi with 400 precision drilled holes and a base section which holds a standard dish for agar media. The Allegro Impactor is a proven performer for collecting viable mold samples

9804-15: Allegro Impactor

Flow Meter
Allegro's flow meters are separate from the pump to allow the user to set the flow for more than one pump with the same meter. Features an expanded scale and includes necessary adapters for use with particulate cassettes.

9804-03: Flow Meter, 0 - 20 LPM
9804-031: Flow Meter, 3 - 30 LPM
9801-03: DC sampler flow meter

Primary Calibrator
Using bubble flow for high volume samples.

9803-50: Primary Calibrator

Tape Sampler
Sampling of possible microbial, bioaerosol and inorganic dust contamination is made easy and effective with Tape Sampler. A flexible plastic microscope slide with a pre-defined 1" x 1" adhesive area allows you to quickly take a sample and measure the degree of contamination. Perfect for non-transportable materials. Each slide has a unique serial number for traceability and packed in a slide mailer to prevent cross contamination. 10/pkg.

9803-14: Tape Sampler

DIAPHRAGM SAMPLING PUMP
This cost effective and maintenance free pulsating diaphragm pump will operate efficiently with mold, PCM and TEM cassettes. Lightweight at only 10 lbs., the pump comes complete with an adjustable regulator and aluminum tripod, clear vinyl tubing, and a power cord with switch.

Part No. 9805 Diaphragm Sampling Pump with Stand
Part No. 9805-88 Diaphragm Sampling Pump without Stand

Sampling Pump Carry Bag
High quality nylon bag is padded to protect your sampling products. The large bag is designed to contain up to two sampling pumps with stands, cassettes, impactors, and all of your on-the-job sampling needs.

9801-B: Sampling Pump Carry Bag

WSP home page Products page Suppliers page
Allegro Index Previous Allegro Page Next Allegro Page