For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
![]() |
| Dimensions with handle collapsed: 23"L X 21"W X 25"H |
Front view, handle up |
![]() |
![]() |
| +20 degree upward tilt | -14 degree downward tilt |
Air Systems has the first PPV blower in the industry with all the features that are demanded by fire service and industry professionals.
|
|
| Model | Description | Engine | HP | CFM | Set Back | # of Blades | Blade Size | Weight |
| PPV-20GH | Gasoline | Honda | 6.0 | 15.277 | 6 ft. | 8 | 20" | 67 lbs |
| PPV-20E | Single Speed | Electric - TEFC | 1.5 | 11.198 | 6 ft. | 8 | 20" | 76 lbs |
| PPV-20EV | Variable Speed | Electric - TEFC | 1 | 10.987 | 6 ft. | 4 | 20" | 79 lbs |
| PPV-20EXP | Explosion Proof Class I, Div. 1 Group D, Class II Div. 1, Groups E, F, G |
Electric - TEFC | 1 | 9.185 | 6 ft. | 4 | 20" | 81 lbs |
| Air Systems manufactures a combination ventilation fan and duct storage unit to meet the most demanding customer needs. The rugged polyethylene duct canister is securely attached to one of Air Systems' rugged lightweight fans to make an ideal ventilator for the customer who wants a one piece ventilation package. | |
![]() |
![]() |
| SVF-8AC | SVF-15DCAN (Canister Fan) |
AC Version (SVF-8AC):
DC Version (SVF-8DC):
|
|
![]() |
![]() |
| SVF-108ADP | Blowers in series for long duct runs (10" Axial Blower) |
![]() |
![]() |
| 10" to 8" Duct Adapters for 10" Axial Blowers |
SVF-10EXP (10" In-Line Axial Blower) Explosion proof |
This 10" portable blower series has been developed for the customer who may need to run long lengths of ventilation duct. This can easily be accomplished with Air Systems' economical tube axial 10" diameter ventilator. Intake and exhaust flanges allow for either 8" or 10" duct to be attached to either end of the blower with multiple blowers placed in series to achieve positive or negative ventilation. The blower is lightweight and weighs less than thirty pounds. It is available in standard electric or CSA approved explosion proof electric.
|
|
| Ordering Information for Portable Axial Fans & In-Line Axial Blowers | |
| Model | Description |
| Axial Fans | |
| SVF-8AC | AC axial fan - 1395 cfm free air |
| SVF-8DC | DC axial fan - 1170 cfm free air |
| Duct Canister Fans | |
| SVF-6ACAN | AC axial canister fan with 6 ft. duct installed - 890 cfm |
| SVF-15ACAN | AC axial canister fan with 15 ft duct installed - 870 cfm |
| SVF-25ACAN | AC axial canister fan with 25 ft duct installed - 858 cfm |
| SVF-6DCAN | DC axial canister fan with 6 ft duct installed - 825 cfm |
| SVF-15DCAN | DC axial canister fan with 15 ft duct installed - 815 cfm |
| SVF-25DCAN | DC axial canister fan with 25 ft duct installed - 796 cfm |
| 10" In-Line Axial Blowers | |
| SVF-10E | 10" standard electric in-line fan |
| SVF-10EXP | 10" explosion proof electric in-line fan |
![]() |
|
![]() |
SV-189 |
| The Saddle Vent® was invented by a professional tank cleaner to make it easy for his workers to enter and exit a confined space. The Saddle Vent® takes up only 3 inches in a manhole and functions as an air conduit. Eight inch air hose is attached to both ends of the Saddle Vent® and placed in the entry access hole, thus eliminating the need to remove the hose each time entry or egress is required. The Saddle Vent revolutionizes confined space operations by offering a level of safety and productivity that has never been available. One model is available for industrial manhole work, and a specific model is designed for doing tank entry work. The Saddle Vent's unique air flow design does not reduce air flow to the worker. The Saddle Vent ventilator provides continuous access to the manhole for either entry or egress. Traveling in and out of the confined space can now be done quickly and safely. The Saddle Vent increases worker productivity as well as the ability to perform confined space entry rescue. The entire Saddle Vent system can be completely set up in less than five minutes. Eight inch air duct is installed on the bottom of the Saddle Vent and run to the bottom of the manhole; this allows fresh air to be supplied to the workers and displace any harmful gases that may be deadly for the occupants. The use of the 90º elbow removes the severe kink in the air duct and allows for rotation of the intake duct to any desired position at the street level. Saddle Vent® is a registered trademark of Air Systems International. Specifications for industrial model Saddle Vent SV-189 (shown above)
|
|
![]() |
![]() |
| Conductive Saddle Vent in use | SV-189CND |
![]() |
![]() |
| Air Systems is introducing a second industrial style Saddle Vent and elbow manufactured from conductive polyethylene material. The recent development of this conductive material provides for a level of safety during confined space ventilation that has not been available to industry. During confined space ventilation, static electricity can build up on the surface of the ventilation ducting and the standard orange polyethylene Saddle Vent. Given the right conditions of humidity, airborne dust and static buildup, the static electricity can discharge and cause a spark. If this occurs while working in an explosive or potentially explosive environment, a major accident could result. The only safe way to prevent this source of ignition during ventilation is to remove the static electricity through proper grounding of the entire ventilation system. Standard PVC ducting and polyethylenen can retain static electricity and should not be used if there is a potential for the existence of explosive gases in the confined space. Air Systems can now offer is Conductive Saddle Vent system to improve the safety of workers during confined space ventilation. The new black Saddle Vent and companion 90º elbow is manufactured with conductive polyethylene material. Grounding lugs are mounted on each device. They are used to connect the steel grounding wire provided with conductive ducting to the conductive Saddle Vent and elbow. This make a complete electrical circuit all the way back to the explosion proof blower where the final grounding lug is located. The electrical blower must be connected to a grounded electrical source and thus completes the full electrical circuit. This circuit provides a path for static electricity to travel to a grounded source thus preventing a build up of the surface of the ducting or Saddle Vent. For work in explosive environments, read and follow recommended work procedures found in ANSI/API 2015 and 2016 prior to entering a tank or confined space. |
|
| Model | Description |
| SV-189CND | Conductive Saddle Vent |
| SV-90CND | Conductive 90º elbow for top of Saddle Vent |
| SV-CUPCND | Conductive Saddle Vent ventilation accessory kit includes: Conductive Saddle Vent, Conductive elbow, Duct carrier, 6 ft. and 15 ft. conductive ducting with ground wire on each end, and a steel universal mount |
![]() |
![]() |
| SVB-E8 Single speed electric blower
|
SVB-E8-2 2-Speed electric blower with GFI
|
![]() |
![]() |
| SVB-G8 Gasoline powered blower
|
SVB-E8EXP Explosion proof electric blower
|
![]() |
![]() |
| SVB-E8EC Economy electric blower
|
SVB-A8 Pneumatic air powered blower - intrinsically safe
|
| Confined space ventilation kits: All kits include 1 each of the following items
|
|
![]() SVB-E8SCUP |
|
| Model | Description |
| SVB-E8SCUP | Standard electric blower kit (shown above) |
| SVB-E82CUP | 2-speed electric blower kit |
| SVB-G8CUP | Gasoline blower kit |
| SVB-A8CUP | Pneumatic blower kit |
| SVB-E8XCUP | Explosion proof electric blower kit (supplied with Conductive Saddle Vent and ducting) |
| SVB-E8CUP | Economy electric blower kit |
![]() |
![]() |
| Standard ducting with 8-3/8" "Bell" cuff and buckle standard on both ends | Conductive ducting with ground wires on both ends |
![]() |
![]() |
| Duct Connectors | Duct carrier |
![]() |
![]() |
SV-189-29 (Saddlator - pneumatic powered Saddle Vent blower)
|
In-Line filter holder
|
![]() |
![]() |
| 90º Elbow for top of Saddle Vent | SV-189T (Tank model Saddle Vent)
The patented tank model Saddle Vent is specially designed to fit 18"W X 20"L oval tanks. The tank model is installed in the hatch entry area with complete entry and egress access to the ladder. The required metal guard is left in place without interference from the Tank Saddle Vent |
| Model | Description |
| Standard ducting | |
| SVH-6 | 8" diameter 6 ft vinyl hose duct |
| SVH-15 | 8" diameter 15 ft vinyl hose duct |
| SVH-25 | 8" diameter 25 ft vinyl hose duct |
| Conductive ducting | |
| SVH-CND825 | 8" diameter 25 ft conductive duct |
| SVH-CND815 | 8" diameter 15 ft conductive duct |
| SVH-CND86 | 8" diameter 6 ft conductive duct |
| Duct to duct connectors | |
| SVH-88C | 8" duct to duct connector |
| SVH-88CND | 8" conductive polyethylene duct to duct connector w/ground lugs |
| In-Line filter holders | |
| FH24-8 | In-Line filter holder |
| ASI-242C | Carbon odor removal filter, 24" X 24" X 2" |
| FLTR004C | Dust filter, 24" X 24" X 2" |
| Saddle Vent Accessories | |
| SV-189-29 | Industrial model Saddlator w/elbow |
| SV90-29 | 90º bolt-on elbow to fit Saddlator |
| SV189T-29 | Tank model Saddlator |
| H50-5 | 1/2" compressor connect hose - 50 ft |
| H50-12 | 3/4" compressor connect hose - 50 ft |
![]() |
|
Air Systems can design a blower to meet your most demanding requirements. Air Systems' blowers are used by steel mills, shipbuilding companies and power generating stations. Select from a wide variety and style of inlet and outlet flange sizes. The blower shown above is a 15 HP electric with a 14" inlet and outlet flange. It is set on a 4-way steel fork lift skid. This blower has been designed to deliver high static pressure and cfm output for maximum lengths of ducting.
|
|
![]() |
![]() |
Propane ventilation heater
|
|
![]() |
![]() |
| SVF-DCBP15
DC powered axial fans (battery pack not included)
Jump-N-Carry® 950 battery pack
|
Standard and custom blower carts
Air Systems manufactures standard and custom blower carts for mobile applications. The standard cart shown above measures 30"W X 30"D X 42"H, weighs 90 lbs, has a 12"W X 12"D X 26"L hinged top storage box for tools and equipment. Solid fixed rear casters and front locking swivel casters provide smooth maneuvering over a variety of surfaces. Blowers must be ordered separately. |
| Model | Description |
| Battery powered axial fans | |
| SVF-8DCBP | DC axial fan (no canister), 22 lbs, 1170 cfm free air |
| SVF-8DCBP15 | DC axial canister fan, 35 lbs, with 15 ft duct |
| SVF-8DCBP25 | DC axial canister fan, 39 lbs, with 25 ft duct |
| BP-950 | Jump-N-Carry battery pack |
| Propane ventilation heaters | |
| SVF-H70 | Propane heater |
| SVF-H70R | Regulator assembly for heater, high flow |
| SVH-H70-3 | 8" X 3 ft heater connect hose (allows standard industrial 8" blowers to attach to heater |
![]() |
![]() |
Venturi Blower Features:
|
Vapor removal system for underground storage tanks |
![]() |
![]() |
| Inlet Pressure | |||
| 40 PSIG | 60 PSIG | 80 PSIG | |
| Model | Total Air Flow | Total Air Flow | Total Air Flow |
| ASI-1000 | 815 cfm | 981 cfm | 1182 cfm |
| ASI-1200 | 1017 cfm | 1231 cfm | 1462 cfm |
| ASI-2900 | 2385 cfm | 2885 cfm | 3347 cfm |
| ASI-4100 | 3152 cfm | 4152 cfm | 4929 cfm |
| Model | Air Consumed | Air Consumed | Air Consumed |
| ASI-1000 | 36 scfm | 50 scfm | 62 scfm |
| ASI-1200 | 36 scfm | 50 scfm | 62 scfm |
| ASI-2900 | 73 scfm | 98 scfm | 124 scfm |
| ASI-4100 | 114 scfm | 152 scfm | 193 scfm |
| Model | Overall Length |
Dia. of Base |
Dia. of Top |
NPT Size |
Bolt Circle Dia. |
Base Slot Dia. |
Weight |
| ASI-1000 | 16.75" | 7.31" | 6.0" | 1/2" | 6.56" | 0.4" | 5.5 lbs |
| ASI-1200 | 30.5" | 7.31" | 7.0" | 1/2" | 6.56" | 0.4" | 8.5 lbs |
| ASI-2900 | 44.25" | 11.25" | 12.5" | 1" | 10.5" | 0.4" | 22.3 lbs |
| ASI-4100 | 46.06" | 14.37" | 14.25" | 1" | 13.62" | 0.5" | 36 lbs |
| WSP home page | Products page | Suppliers page | Air Systems Index |