For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
![]() |
| These portable Grade-D filtration systems are designed to provide breathing air for a specific number of workers. The system filters inlet air to provide respirator users with Grade-D quality air and monitors for CO and/or Oxygen. The first stage element filters bulk water and particulate, and has an auto drain. The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates and has an auto drain. The third stage filter removes organic vapors and odors and has a manual drain. Filter change indicators are standard on all three stages of filtration. Filtration efficiency is 99.99% at .01 micron. All Breather Boxes are designed to be used in the upright and closed position. The standard carbon monoxide monitor operates on disposable 9-volt batteries, 12-volt DC line voltage or 115 VAC for continuous detection. An external alarm and light signals the workers of high CO content. Standard Features:
|
|
| Please specify 1/4" Hansen or Schrader fittings when ordering. Other fittings available for an additional charge. | |
| Model | Description |
| Standard Portable Breather Box | |
| BB15-CO | Standard Breather Box 15 cfm 1 coupling |
| BB15-CO2 | Standard Breather Box 15 cfm 2 couplings |
| BB30-CO | Standard Breather Box 30 cfm 2 couplings |
| BB30-CO3 | Standard Breather Box 30 cfm 3 couplings |
| BB50-CO | Standard Breather Box 50 cfm 4 couplings |
| BB75-CO | Standard Breather Box 75 cfm 6 couplings |
| BB100-CO | Standard Breather Box 100 cfm 4 couplings |
| BB100-CO6 | Standard Breather Box 100 cfm 6 couplings |
| BB100-CO8 | Standard Breather Box 100 cfm 8 couplings |
| BB150-CO | Breather Box supplied with 3 each 1/2" sockets, no regulator. Order POA-4 Boxes and hoses separately |
| Carbon Monoxide & Oxygen Monitoring Versions | |
| BB50-COO2 | Standard Breather Box 50 cfm 4 couplings, CO & Oxygen monitoring |
| BB100-COO2 | Standard Breather Box 100 cfm 4 couplings, CO & Oxygen monitoring |
| Independent Regulator Versions | |
| BB50-CO4R | Standard Breather Box 50 cfm 4 couplings, 4 independent regulators and pressure gauges |
| BB100-CO4R | Standard Breather Box 100 cfm 4 couplings, 4 independent regulators and pressure gauges |
| Intrinsically Safe Versions | |
| BB30-COIS | Intrinsically Safe Breather Box 30 cfm 2 couplings |
| BB50-COIS | Intrinsically Safe Breather Box 50 cfm 4 couplings |
| BB100-COIS | Intrinsically Safe Breather Box 100 cfm 4 couplings |
| All models available with "IS" (Intrinsically Safe) version monitors | |
| Intrinsically Safe (IS) versions are CSA approved for Class I, Division 1, Groups C and D Environments. Units are "DC" (9-volt) operation only | |
| Remote alarms are available for portable and fixed applications Pneumatic remote alarms are available Over 30 portable models to choose from; 15 to 150 cfm capacities; outlet options for 1 to 16 workers |
|
![]() |
|
| Cylinder air and plant air all in one cart. The Dual Air Cart system has been designed for the customer who needs both emergency short duration bottled air and continuous duty Grade-D plant air filtration all in one cart. The Dual Air cart provides for both applications on one cart and allows the user to convert his existing Air Systems' Breather Box equipment for use on the new Dual Air series cart. This new system saves the customer time and money and provides a level of emergency response not available in the past. The Dual Air cart is ordered complete with a built in high pressure (5000 psi) regulator, 2 high pressure (CGA-347) connect whips with hand tight nuts, and one low pressure connect hose from the regulator. The connect hose attaches to the Breather Box when cylinder air is required. The cylinder air passes through the filter system and is distributed to the respirators through the Breather Box manifold and regulator system. A rear collapsible hose rack, pneumatic 10" tires, bottle straps, and front storage box are supplied standard on the Dual Air cart system. |
|
| Model | Description |
| DAC-30 | Dual Air Cart with BB30-CO Breather Box, cylinders not included |
| DAC-50 | Dual Air Cart with BB50-CO Breather Box, cylinders not included |
| DAC-100 | Dual Air Cart with BB100-CO Breather Box, cylinders not included |
![]() |
|
| The Blast Air Cart has been designed for the commercial sandblast/paint industry and industrial plants that need advanced, high capacity air filtration. The Blast Air 50 pictured above is Air Systems' standard 50 cfm Breather Box mounted on a BA-1C prefilter cart. These rugged pre-filters automatically drain large amounts of oil and water from mobile compressors before it enters the Breather Box. This process will extend the filter life of the Breather Box and reduce maintenance downtime and costs. Any of our portable Breather Box models can be fitted to our BA-1C Blast Air Cart. The Blast Air Cart is ideal for rental use because the pre-filter helps prevent damage to the Breather Box filtration system and extends its life. When ordering, please specify Hansen or Schrader fittings. Other fittings available for an additional charge. |
|
| Model | Description |
| BA-30 | 30 cfm Breather Box installed on the Blast Air Cart |
| BA-50 | 50 cfm Breather Box installed on the Blast Air Cart |
| BA-100 | 100 cfm Breather Box installed on the Blast Air Cart |
| BA-1C | Blast Air Cart only, with rear filters and connect hose |
![]() |
![]() |
![]() |
| BB50-COAA | BB100COAAP | Connection details |
| The Auto-Air filtration system was developed to provide automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in IDLH or hazardous environments. In the event of a pressure or electrical failure, the Auto-Air system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and switched to the back-up air system. NIOSH requires the use of a 5 minute airline escape respirator when working in IDLH environments. Our Auto-Air feature does not replace the NIOSH requirement, however, some work environments may require a 30-minute (or longer) airline escape method to safely egress the hazardous area. This situation would require the use of an Auto-Air Box or cart. The primary air line connection is attached from the compressor. A reserve air line is attached from a reserve bank of air cylinders based on the required egress duration. The system can be tested prior to each use to ensure proper function of the Auto-Air system. Specifications:
|
||
| Please specify 1/4" Hansen or Schrader fittings when ordering. Other fittings available for an additional charge. NOTE: size the reserve air system (cylinders) to achieve the required egress time. |
|
| Model | Description |
| Standard Electric Versions | |
| BB30-COAA | Auto-Air Breather Box, 30 cfm |
| BB50-COAA | Auto-Air Breather Box, 50 cfm |
| BB100-COAA | Auto-Air Breather Box, 100 cfm |
| Intrinsically safe Pneumatic Versions | |
| BB50-COAAP | Intrinsically safe Auto-Air Breather Box, 50 cfm |
| BB100-COAAP | Intrinsically safe Auto-Air Breather Box, 100 cfm |
| Optional Reserve Air Cylinders | |
| AC-60 | 60 cf aluminum cylinder - 2400 psi rated - 30 minute |
| AC-87 | 87 cf carbon fiber cylinder - 4500 psi rated - 1 hour |
| NOTE: Intrinsically safe (IS) versions are CSA approved for Class I, Division 1, Groups C and D environments. Units are "DC" (9-volt) operation only. | |
![]() |
![]() |
![]() |
| B10023HTAP
Intrinsically safe, complete pneumatic operation. |
Customized Auto-Air Cart installed on Ergo-Air Cart frame. This unit holds two 444 cf air cylinders and provides ease of mobility. Any size Breather Box can be added to the Ergo-Air Cart frame |
BB50-HTAA
Standard Electric Version |
| Auto-Air Carts provide fully automatic reserve air for work in hazardous environments. The Auto-Air Cart provides a system approach to breathing air filtration. On unit contains a full Grade-D filtration unit and either a pneumatic or electric reserve air system. Choose a cart size based on the desired amount of reserve air to allow workers to safely egress the work area. The pneumatic versions should be selected in hazardous and potentially explosive environments.
Custom Auto-Air Carts available. Call Western Safety for more information. All BB30 through BB100 series standard carts hold two 87 or 60 cf air cylinders. Optional large cylinder carts are available for long duration applications. |
||
| Model | Description |
| Standard Electric Versions | |
| BB50-HTAA | Auto-Air Cart - 50 cfm, requires 115 VAC for operation |
| BB100-HTAA | Auto-Air Cart - 100 cfm, requires 115 VAC for operation |
| BB100-23AA | Auto-Air Cart - 100 cfm, requires 115 VAC for operation. System supplied with large cylinder cart |
| Intrinsically Safe Pneumatic Versions | |
| BB50HTAAP | Intrinsically safe Auto-Air Cart - 50 cfm |
| BB100HTAAP | Intrinsically safe Auto-Air Cart - 100 cfm |
| B10023HTAP | Intrinsically safe Auto-Air Cart - 100 cfm. System supplied with large cylinder cart |
| NOTE: Intrinsically safe (IS) versions are CSA approved for Class I, Division 1, Groups C and D environments. Units are "DC" (9-volt) operation only. | |
| These fixed Grade-D filtration systems are designed to provide breathing air for a specific number of workers. The system filters inlet air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulates; the second stage coalescing filter removes atomized oils and ultra-fine particulates, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% at .01 microns. A built in carbon monoxide monitor operates on a 9-volt DC and/or 115 VAC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard.
Auto-Air Option: |
|
![]() |
![]() |
| BB30-COPM | BB50-COPM |
|
|
![]() |
![]() |
| B50-COPMEX
Explosion proof filtration system
|
50-EXALPST
Explosion proof remote dual alarm
|
![]() |
|
| BB15-COPM
Single user Grade-D air panel
|
|
| Please specify 1/4" Hansen or Schrader fittings when ordering. Other fittings available for an additional charge. | |
| Model | Description |
| Breathing Air Panel Models CO Versions | |
| BB15-COPM | Single user Grade-D breathing air panel with CO monitor - 15 cfm - 1 coupling |
| BB30-COPM | Standard Grade-D breathing air panel with CO monitor - 30 cfm - 2 couplings |
| BB50-COPM | Standard Grade-D breathing air panel with CO monitor - 50 cfm - 4 couplings |
| BB75-COPM | Standard Grade-D breathing air panel with CO monitor - 75 cfm - 6 couplings or NPT outlet |
| BB100-COPM | Standard Grade-D breathing air panel with CO monitor - 100 cfm - 4 couplings or NPT outlet |
| BB150-COPM | Standard Grade-D breathing air panel with CO monitor - 150 cfm - NPT outlet |
| BB250-COPM | Standard Grade-D breathing air panel with CO monitor - 250 cfm - NPT outlet |
| BB650-COPM | Standard Grade-D breathing air panel with CO monitor - 650 cfm - NPT outlet |
| Carbon Monoxide & Oxygen Monitoring Panels | |
| BB50-CO2PM | Grade-D breathing air panel with CO/O2 monitor - 50 cfm - 4 couplings |
| BB100-CO2PM | Grade-D breathing air panel with CO/O2 monitor - 100 cfm - 4/6 couplings or NPT outlet |
| Auto-Air Panel Models | |
| BB50-COAAPM | Auto-Air Grade-D breathing air panel with CO monitor - 50 cfm - 4 couplings |
| Intrinsically Safe Models (Option available on all panels) | |
| BB15COPMIS | Grade-D breathing air panel wit intrinsically safe CO monitor - 15 cfm - 1 coupling |
| BB30COPMIS | Grade-D breathing air panel wit intrinsically safe CO monitor - 30 cfm - 2 coupling |
| BB30-COPMIS | Grade-D breathing air panel wit intrinsically safe CO monitor - 150 cfm - 4 coupling |
| NOTE: Intrinsically safe (IS) versions are CSA approved for Class I, Division 1, Groups C and D environments. Units are "DC" (9-volt) operation only. | |
![]() |
![]() |
![]() |
| CO-91
Carbon Monoxide Monitor |
CO-91IS
Intrinsically safe CSA approved CO Monitor |
CO2-91
Dual oxygen and carbon monoxide monitor |
Two year system and sensor warranty.
|
||
![]() |
![]() |
| CO91-14LAC | CO-91PM |
| For intermittent or continuous sampling This portable monitor unit connects easily to any high or low pressure compressed air breathing source and monitors CO content in air. The audible alarm (90 dBA) will activate when the CO level exceeds 10 ppm (5 ppm international). External alarm and lights allow unit to be used in closed position
|
Fixed system for continuous sampling of CO and/or O2 levels This durable carbon monoxide airline monitor can be ordered to retrofit any existing Grade-D breathing air system. It can be ordered with dual monitoring of CO and oxygen. A CSA approved monitor is also available with 9-volt DC operation only for intrinsically safe applications. Units supplied with high intensity audible alarm and 115 VAC power cord. All units are powder coated steel and are ready for wall or panel mounting. |
| The Point-Of-Attachment (POA) series provides remote manifold capabilities for respirator users, while complying with NIOSH regulations. the POA series consists of a regulator, pressure gauge, safety relief valve, and fittings necessary for proper respirator operation. The POA box can be located any distance from the Grade-D filtration Breather Box or filtration panel. This POA manifold assembly, where the respirator attaches, is now limited to a maximum of 300 feet of breathing air hose at the air outlet fitting. Available for 1 to 8 workers. | ||
![]() |
![]() |
![]() |
| POA-4 | POA-4R | POA-5RF |
|
Four independent regulators allow each worker to adjust their desired pressure depending on the brand / style of respirator and length of hose. | Custom units like the one above can be configured to meet the most demanding needs. Available options:
|
![]() |
![]() |
|
| PF-240
Portable Pre-Filter (1/2" Chicago inlet fitting; 1/2" Industrial Interchange outlet fitting)
|
POA-XWM
Wall Mounted POA Manifold
|
|
| Please specify 1/4" Hansen or Schrader fittings when ordering. Other fittings available for an additional charge | |
| Model | Description |
| POA-4 | Standard POA box - 4 couplings |
| POA-4R | POA box with 4 independent regulators |
| POA-4F | POA box with final particulate filter |
| POA-4RF | POA box with final particulate filter and 4 independent regulators |
| BBM-4LF | "NRC" POA box, final particulate filter, 4 independent regulators, low pressure warning alarm and lights (a clear gauge viewing window is optional) |
| POA"X"WM | Wall mounted POA manifold. Replace "X" in part number (without quotes) with required number of fittings |
![]() |
![]() |
| Breathing air hose 3/8", 1/2", 3/4" ID in stock. Specify desired coupling, fitting size and hose length when ordering |
Couplings and Fittings for breathing equipment |
![]() |
![]() |
![]() |
| Breathing Air Hose Reels | 50-ALMST
Remote Alarm |
ALMSTH120
Remote Alarm with strobe |
![]() |
![]() |
|
| BBK-20
Airline monitor calibration kit |
BBK-20103
Airline monitor calibration kits |
| Automatic Rewind Hose Reels 3/8" Hose (150 psi max) | |
| HR-50 | Automatic hose reel holds 50' of 3/8" ID breathing air hose with automatic retracting and multiposition installation |
| HR-50SS | Stainless steel automatic hose reel holds up to 50 " of 3/8" ID breathing air hose with automatic retracting and multiposition installation |
| HR-50POA | NIOSH point of attachment automatic hose reel holds 50' of 3/8" ID breathing air hose with installed regulator, pressure gauge and safety relief valve - use with NIOSH approved respirator hose |
| Automatic Rewind Hose Reels 1/2" Hose (150 psi max) | |
| HR-505 | Holds up to 50' of 1/2" ID breathing air hose with auto retracting and multiposition installation |
| HR-575 | Holds up to 75' of 1/2" ID breathing air hose with auto retracting and multiposition installation |
| Manual Hose Reels (150 psi max) | |
| HR-100M | Manual hose reel holds 100' of 3/8" ID hose or 50' of 1/2" ID breathing air hose |
| HR-400M | Manual hose reel holds 400' of 3/8" ID hose or 200' of 1/2" ID breathing air hose |
| HR-550M | Manual hose reel holds 550' of 3/8" ID hose or 300' of 1/2" ID breathing air hose |
| HR-500MC | Manual hose reel cart with fold down handle and holds 400' of 3/8" or 300' of 1/2" ID breathing air hose |
| High Pressure Hose Reels (5000 psi max) | |
| HPR-350 | Auto hose reel holds 50' of 1/4" ID high pressure air hose |
| HPR-300M | Manual hose reel hold 300' of 1/4" ID high pressure air hose |
| Remote Alarms: These alarm units have been designed to duplicate local alarms found on the primary equipment and to signal workers in a remote location that there is an alarm condition with their system. They act as a valuable early-warning device for the isolated worker and allows him to make a safe egress from a hazardous work environment. Portable Breather Box units require DC alarms. Wall mount filter panels require AC alarms. |
|
| For Standard Breather Box Models | |
| 50-ALM | Remote audible alarm with 50 ft. cable, 9 - 12 VDC |
| 50-ALMST | Remote audible alarm with mounted visual strobe and guard - 50 ft. cable, 9 - 12 VDC |
| 50-ALMSTH | Remote high intensity audible alarmwith mounted visual strobe and guard - 50 ft. cable, 9 - 12 VDC |
| For Panel Mounted Filtration Models | |
| EXAL | Explosion proof audible alarm - no cable, 120 VAC |
| EXVST | Explosion proof visual strobe alarm - no cable, 120 VAC |
| ALMSTH120 | Remote audible/visual strobe w/conduit box, no cable, 120VAC |
| Airline Monitor Calibration Kits | |
| BBK-20 | Calibration kit for CO monitor - 20 ppm CO, zero air, regulator and case - 17 liter size disposable cylinders |
| BBK-10 | Calibration kit - same as above with 10 ppm CO gas for international calibration |
| BBK-20103 | Large calibration kit includes 1 cylinder 20 ppm CO, 1 cylinder zero air, regulator, pressure gauge, tubing and hard case - 103 liter size disposable cylinders |
![]() |
|
| Complete test kit Model LP/HP-A4K | |
| Air Systems' breathing air quality test kits are designed to test the air produced by compressors (Model LP-A4) and compressed air in cylinders (Model HP-A4 and HP-A445). These tests are accomplished through the use of low cost detector tubes that provide a "go/no go" test of the air quality. If a high reading is found, this signals the user that they have a potentially unacceptable quality of breathing air. If this occurs, a laboratory analysis of the air components must be made to determine the exact reading of the air quality and take corrective action. | |
![]() |
![]() |
| LP-A4 | Models HP-A445 and HP-A4 |
| Model | Description |
| HP-1A | Replacement carbon monoxide test tube - 10/box |
| HP-2A | Replacement carbon dioxide test tube - 10/box |
| HP-6A | Replacement water vapor test tube - 10/box |
| HP-109AD | Replacement oil mist test tube - 10/box |
| HP-A4 | Cylinder air test module - 3000 psi max - use with test module LP-A4 |
| HP-A445 | Cylinder air test module - 5000 psi max - use with test module LP-A4 |
| LP-47PF | Total particulate test module - 20 psi max - add to test modules above - includes one filter |
| LP-A4 | Compressor air quality test module - 100 psi max |
| Complete Test Kits | |
| LP/HP-A4K | Consists of LP-A4, HP-A4, LP-47PF, 4 boxes assorted test tubes, polycarbonate padded carry case - 3000 psi max |
| LP/HPA445K | Same as above kit, includes HP-A445 test module in place of HP-A4 module - 5000 psi max |
![]() |
|
| The model AQT-O2 Air Quality Test Meter has been developed out of a need to test rented cylinder blended air quality before putting them to use. Obtain an immediate and accurate oxygen reading for both high pressure cylinder air and low pressure plant air lines. The tester can be ordered with an additional sensor to read carbon monoxide simultaneously with oxygen - order Model AQT-COO2. The tester requires two 9-volt batteries for operation and is supplied with 5 feet of hose. For cylinder testing, order the optional high pressure adapter shown below, part no. AQT-347LP The Air Quality Test Meter is supplied with low pressure air hose and a male 1/4" Hansen 3000 series plug for direct attachment to any low pressure (under 120 psi) Grade-D air source. Specify desired fitting when ordering (if different from Hansen). |
|
| AQT-O2 | Air Quality Test Meter, oxygen only, max pressure 125 psi |
| AQT-COO2 | Air Quality Test Meter, CO and O2, max pressure 125 psi |
| AQT-347LP | High pressure air cylinder adapter, 5000 psi max |
| BBK-20 | Calibration Kit |
| All meters are supplied with 5 feet of test hose and a 1/4" Hansen or Schrader low pressure plug. For cylinder air testing, order high pressure cylinder adapter below. | |
![]() |
| When testing bottled air cylinders, the AQT-347LP adapter must be ordered. It reduces cylinder pressures up to 5000 psi down to 100 psi. The AQT's sample hose can then be plugged directly into the air cylinder adapter. |
![]() |
| Certified laboratory air testing is now available for high pressure bottled air or low pressure compressor air requirements. Take your own samples in 10 minutes and send out for precise laboratory results. A 2LA accredited lab will test to any recognized standards, e.g., CGA, NFPA, or Federal MIL Specs. Results can be obtained in less than 3 days; same day service is available for additional charge.
Air sampling kits available for purchase. Call Western Safety for more information. |
| WSP home page | Products page | Suppliers page | |
| Respiratory Protection | Air Pumps | Air Systems Index | Next Air Systems Page |