For more information, call Western Safety Products at 206-264-0808 or email sales@westernsafety.com.

![]() |
The boom mounted lift arm can be utilized as a 3Ø or 1Ø lifting attachment when mounted, to derrick trucks and bucket trucks that have lifting capabilities. It can be used for change out of poles, cross arms, insulators and midspan lifting requirements.
|
| Cat. No. 11686 Boom Bracket with Ratchet Assembly Fits booms 8"x 8" to 11" x 11" Weight: 38 lbs. |
Cat. No. 11683 5' x 3" O.D. Mast Assembly Only With quick detach pin Weight: 9.3 lbs. |
Arm Assemblies Cat. No. 13128 - 9' x 3" O.D. Arm with Cat. No. 11974 swivel support, Cat. No. 12006 brace, two Cat. No. 11387 brace clamps and three Cat. No. 5034 four way rollers Weight: 37 lbs. Cat. No. 13129 - same as above except arm is 11' x 3" O.D. Weight: 40 lbs. |
|
| Cat. No. 21642 Self Aligning Conductor Holder For attachment to mast. Opening is 1-1/2". Spring loaded latch is hot stick operable. Max. work load 300 lbs. Weight: 4.5 lbs. |
Cat. No. 12666 Super Duty Conductor Holder For attachment to mast and jib adapters accepts 2" dia. conductors. Max. work load 500 lbs. Weight: 11 lbs. |
Cat. No. 5034 Four Way Conductor Holder For mounting to 3" O.D. arm. Opening is 1-1/2". Spring loaded latch is hot stick operable Weight: 4 lbs. |
Cat. No. 12366 Suspension Insulator String Holder For attachment to mast. Unit works on both 9" and 10" dia. insulators Weight: 9.5 lbs. |
![]() |
||
| Cat. No. 12006 57" x 1-1/2" O.D. Brace Pole For attachment to arm assembly and mast Weight: 3.2 lbs. |
Cat. No. 11387 Brace Clamp For attachment of brace pole. Fits 3" O.D. arm and mast assemblies. Weight: 3.1 lbs. |
Cat. No. 5033 Four Way Conductor Holder With insulator for mounting to 3" O.D. arm. Spring loaded latch is hot stick operable Weight: 5 lbs. |
| Cat. No. A16018 Epoxy Insulator For attachment to conductor holder. Cat. No. 5034. Use of insulator allows lift arm to be used on 34.5 KV |
Cat. No. 13148 Metal Sleeve Adapter Adapts 3" O.D. mast to 2-1/2" female sockets (Hi Ranger) Clevis pin is included Weight: 9.2 lbs. |
Cat. No. 13495 Brace Clamp To fit truck jib dia. 3.80 O.D. (McCabe Powers) allows use of Cat. No. 12006 brace pole Weight: 1.5 lbs. |
| Cat. No. 13521 Fiberglass sleeve adapter Adapter O.D. is 2.975" and adapts 3" arm assembly and accessories to truck jib (McCabe Powers) Weight: 3 lbs. |
Cat No. 21401 Brace Clamp To fit truck jib dia.5-1/8" O.D. (Holan) Allows use of Cat. No. 12006 brace pole |
|
![]() |
||
| Cat. No. | Description | Weight |
| Square Jib Adapter For mounting arm assemblies and attachments |
||
| 3487 | Jib adapter for 4" x 4" square FG jibs. Adapter fits Teco and Pitman Units | 4 lbs. |
| 3488 | Jib adapter for 4" x 4" square FG jibs with metal insert. Adapter fits Holan units | 4 lbs. |
| 3498 | Jib adapter for Hi Ranger models 5H and 6H units. Adapter mounts to metal clevis on end of jib assembly | 4 lbs. |
| 3479 | Jib adapter for Altec 4.1" x 4.1" square jibs | 4 lbs. |
| Round Jib Adapter | ||
| 3497 | Jib adapter for Altec jibs. Fits over 3" O.D. jib | 4 lbs. |
| 3491 | Jib adapter for Tel-E-Lect. Jibs fit into 3-1/4" I.D. jib | 4 lbs. |
| 12603 | Jib adapter for Holan jibs. Fit into 2-1/2" I.D. jib | 4 lbs. |
| 3492 | Jib adapter for McCabe Powers. Fits into 3" I.D. jib | 4 lbs. |
| 3521 | Jib adapter for Asplundh model LB 250. Fits into 2-11/16" I.D. jib | 4 lbs. |
| 3522 | Jib adapter for Tel-E-Lect model TS-362. Fits into 2-1/4" I.D. jib | 4 lbs. |
| Square Jib Brace Adapter for attaching brace pole to 4" x 4" FG jibs | ||
| 3489 | Square jib brace pole adapter for 4" x 4" jibs. Adapts to Teco, Holan, Pitman, and Hi Ranger material handling units | 4.5 lbs. |
| Round Jib Brace Adapter for attaching brace pole to round FG jibs | ||
| 13495 | Brace clamp for jib diameter 3.80 O.D. McCabe Powers | 1.5 lbs. |
| 21401 | Brace clamp for jib diameter 5-1/8" O.D. Holan | 1.75 lbs. |
| 3493 | Brace clamp for jib diameter 4" O.D. Altec | 1.4 lbs. |
| 3494 | Brace clamp for jib diameter 4.25" O.D. Tel-E-Lect | 2.4 lbs. |
![]() |
||
Emergency release lanyard for use with lift arms and single conductor lift heads
|
||
| Cat. No. | Item | Weight |
| 5043 | Set of 3 complete lanyards | 3.6 lbs. |
| 5044 | 1 individual lanyard complete | 1.2 lbs. |
Super duty self aligning conductor holder
|
||
| 12666 | 11 lbs. | |
![]() |
||
|
||
| Cat. No. | Description | Weight |
| 12211 | Adapter set to fit 8" O.D. round boom | 18 lbs. |
| 12969 | Adapter set to fit 9" O.D. round boom | 19 lbs. |
| 12979 | Adapter set to fit 10-1/8" O.D. round boom | 20 lbs. |
| 6725 | Adapter set to fit 12" O.D. round boom | 21 lbs. |
| Note: By attaching or installing any of the above adapter kits, the lift arm assemblies shown in table on top can then be utilized on trucks with round booms | ||
![]() |
||
• The rubber glove auxiliary arm provides a convenient tool for holding up to four conductors while changing out cross arms, insulators, poles, hardware or obtaining work clearances. |
||
| Cat. No. | Description | Weight |
| 10810 | Complete assembly with 9' arm, 4' mast, 3 conductor holders, mounting bases and brace | 36 lbs. |
| 10580 | Same as above except with 10' arm assembly | 37 lbs. |
| A10047 | Additional wire holder | 2.7 lbs. |
| A30008 | Insulator for wire holder | 1 lb. |
![]() |
||||||
• The Hastings Fiber Glass Conductor Gin is designed for lifting conductors when changing out poles, insulators and hardware on armless type structures. |
||||||
| Cat. No. | Dimension Reference | Max Load Rating | Weight | |||
| A | B | C | With Brace | W/O Brace | ||
| 3770 | 31" | 25" | 84" | 600 lbs. | 450 lbs. | 61 lbs. |
![]() |
|||||
• Convertible — base assembly will accept either the 2-1/2" O.D. x 31" long mast or 3" O.D. x 58" long mast. This feature allows operating personnel maximum lifting heights and safe working load limits. |
|||||
| Cat. No. | Description | Dimension | Working Load Limit |
Weight | |
| A | B | ||||
| 5570 | Complete gin assembly with Cat. No. 5574 Base and Cat. No. 5572 Mast | 21-3/4" | 28-1/4" | 600 lbs. | 17.2 lbs. |
| 5571 | Complete gin assembly with Cat. No. 5574 Base and Cat. No. 5573 Mast | 48-3/4" | 54" | 800 lbs. | 27 lbs. |
| 5574 | Convertible base assembly only | -- | -- | -- | 11.8 lbs. |
| 5572 | 2-1/2" O.D. x 31" long mast only | 21-3/4" | -- | 600 lbs. | 5.4 lbs. |
| 5573 | 3" O.D. x 58" long mast only | 48-3/4" | -- | 800 lbs. | 15.2 lbs. |
![]() |
||
The Hastings Fiberglass Storage Bags are designed for safe storage of rubber goods and lineman's equipment. They are made with top quality materials and designed for rugged use. • Canvas Storage Bags are made from #6 heavy white cotton duck material with double lock stitching for long wear. |
||
| Cat. No. | Description | Weight |
RUBBER GLOVE STORAGE BAGS • All storage bags have Velcro fasteners for easy access and closing. |
||
| Canvas Glove Bags | ||
| 01-050 | 8" x 15" deep canvas bag for 14" rubber gloves | 9 oz. |
| 01-051 | 8" x 17" deep canvas bag for 16" rubber gloves | 10 oz. |
| 01-052 | 8" x 19" deep canvas bag for 18" rubber gloves | 11 oz. |
| Vinyl Glove Bags | ||
| 01-054 | 8" x 15" deep canvas bag for 14" rubber gloves | 8 oz. |
| 01-055 | 8" x 17" deep canvas bag for 16" rubber gloves | 9 oz. |
| 01-056 | 8" x 19" deep canvas bag for 18" rubber gloves | 10 oz. |
COMBINATION GLOVE & SLEEVE BAG • All combination bags have velcro fasteners for easy access and closing. |
||
| Canvas Combination Bag | ||
| 01-058 | 8" x 19" canvas bag for sleeves and gloves up to 18" long | 1 lb. 2 oz. |
| Vinyl Combination Bag | ||
| 01-059 | 8" x 19" vinyl bag for sleeves and gloves up to 18" long | 1 lb. |
PADDED PROTECTIVE BAG • Made with safety yellow heavy duty vinyl. |
||
| 01-061 | 9"W x 16"L x 5"D vinyl bag with velcro fastener | 1 lb. 5 oz. |
SLEEVE FORM BAGS • All sleeve form bags have Velcro fasteners for easy access. |
||
| Canvas Sleeve Bag | ||
| 01-063 | 12" tapered to 7" x 27" canvas sleeve bag | 10 oz. |
| 01-064 | 12" tapered to 7" x 29" canvas sleeve bag | 12 oz. |
| Vinyl Sleeve Bag | ||
| 01-065 | 12" tapered to 7" x 27" vinyl sleeve bag | 9 oz. |
| 01-066 | 12" tapered to 7" x 29" vinyl sleeve bag | 11 oz. |
Above, top to bottom, left to right |
||
| Cat. No. | Description | Weight |
Rubber Blanket Roll-Up
|
||
| 01-070 | Roll-up for 24" x 24" rubber blankets | 1 lb. 2 oz. |
| 01-071 | Roll-up for 36" x 36" rubber blankets | 3 lb. 12 oz. |
| 01-072 | Roll-up for 46" x 46" rubber blankets | 4 lb. 6 oz. |
Lineman's Tool Bag
|
||
| 01-077 | 24" x 7" x 15" tool bag with side pocket | 4 lb. 8 oz. |
Line Hose Bag
|
||
| 01-073 | 8" x 31" Hose Bag for 3 ft. long line hose | 1 lb. 2 oz. |
| 01-074 | 8" x 48" Hose Bag for 4.5 ft. long line hose | 3 lbs. 12 oz. |
| 01-075 | 8" x 68" Hose Bag for 6 ft. long line hose | 4 lbs. 6 oz. |
Lineman's Belt Bag
|
||
| 01-079 | 9" x 4" x 9" deep belt bag | 8 oz. |
|
||
| Cat. No. | Description | Weight |
Lineman's Tool Bucket
|
||
| 01-081 | 12" x 15" deep tool bucket with safety snap swivel | 2 lbs. 8 oz. |
| 01-082 | 12" x 15" deep tool bucket without safety snap swivel | 2 lbs. 4 oz. |
Lineman's Service Bucket
|
||
| 01-084 | 10-1/2" x 12" deep service bucket with safety swivel | 2 lbs. 10 oz. |
| 01-085 | 10-1/2" x 12" deep service bucket without safety swivel | 2 lbs. 6 oz. |
Hastings Mini-Bucket
|
||
| EX1-271 | Canvas mini bucket 6" deep x 4.5" diameter | 1 lb. 2 oz. |
![]() |
Grounding Equipment for:
Features and Benefits
|
Above, top to bottom, left to right |
Hanger Studs
|
Cable Ferrules A. Compression ferrule shown above "A" insert should be used when terminating cable on pressure type clamps |
Stress Relief A. Cable clamps and spacers |
Typical Grounding Jumper
|
![]() |
|||||||
| Cat. No. | Description | Main Line Range Max. |
Main Line Range Min. |
Max. Jumper Cable |
Max. Fault Current Rating |
Min. Installtion Torque |
Weight |
| 1810-2 | Single ground clamp Bronze alloy |
336.4 MCM ACSR .75 dia. | 6 Solid .16 dia. | 2 Str. w/ Ferrule | 14,500 Amps, 15 cycles 8,000 Amps, 30cycles |
120 Inch lbs. | 1.1 lbs. |
| 1810 | 1810-2 Grd. clamp mounted on a 1-1/4" x 6' fiberglass pole* | -- | -- | -- | -- | -- | 3.1 lbs. |
| 4706-4 | Single grd. clamp aluminum alloy | 954 MCM ACSR 1.15 dia. | 6 Solid .16 dia. | 4/0 Str. w/ Ferrule | 43.000 Amps, 15 cycles 30,000 Amps, 30 cycles |
120 Inch lbs. | 1.5 lbs. |
| 4708-4 | 4706-4 Grd. clamp mounted on a 1-1/4" x 6' fiberglass pole* | -- | -- | -- | -- | -- | 3.5 lbs. |
| 1810-5 | 3 Wire grd. cluster utilizing Cat. No. 1810-2 grd. clamps | 336.4 MCM ACSR .75 dia. | 6 Solid .16 dia. | 2 Str. w/ Ferrule | 14,500 Amps, 15 cycles 8,000 Amps, 30cycles |
120 Inch lbs. | 5 lbs. |
| 1810-3 | Same as Cat. No. 1810-5 w/ 1-1/4" x 6' fiberglass poles* | -- | -- | -- | -- | -- | 11 lbs. |
| 4805-1 | 3 Wire grd. cluster utilizing Cat. No. 4706-4 Grd. clamps | 954 MCM ACSR 1.15 dia. | 6 Solid .16 dia. | 4/0 Str. w/ Ferrule | 27.000 Amps, 15 cycles 20,000 Amps, 30 cycles |
120 Inch lbs. | 6.8 lbs. |
| 4902-1 | Same as Cat. No. 4805-1 w/ 1-1/4" x 6' fiberglass poles* | -- | -- | -- | -- | -- | 12.8 lbs. |
| 13210 | Hanger Stud fits above catalog numbers - 4706-4 clamp | 0.4 lb. | |||||
| * Note: Ground clamps can be mounted on other lengths of 1-1/4" dia. fiberglass poles. Please specify when ordering | |||||||
![]() |
||||||
ASTM Designation
|
||||||
| Cat. No. | Description | Main Line Range Max. |
Main Line Range Min. |
Max Size Ground Cable |
Fault Current |
Weight |
| 10476 | Ground clamp duckbill snap-on alum. alloy | 900 ACSR 556 MCM (1.16") | 6 Solid (.162") | 4/0 | 43KA @ 15 cycles 30KA @ 30 cycles |
1.5 lbs. |
![]() |
||||||
The 30° angle ground clamp from HASTINGS allows linemen and substation mechanics to easily install grounds beyond the normal reach. This new design by HASTINGS incorporates one solid upper body for attaching the grounding cable. With one solid upper body, multiple points of contact, as in all angle clamps, have been eliminated, thus ensuring that the ground clamp will meet and pass all in-service tests. With this new 30° angle clamp, linemen and substation mechanics can hold their shotgun stick to nearly a horizontal position and install this ground clamp. ASTM Designation |
||||||
| Cat. No. | Description | Main Line Range Max. |
Main Line Range Min. |
Max. Size Ground Cable |
Fault Current |
Weight |
| 10385 | Ground clamp 30º angle C-Head aluminum alloy | 2" di. cable or bus | #4 SOL. .18" dia. | 4/0 | 43KA @ 15 cycles 30KA @ 30 cycles |
2.14 lbs. |
![]() |
|||||||
|
|||||||
| Cat. No. | Description | Main Line Range Max. |
Main Line Range Min. |
Max. Jumper Cable |
Max. Fault Current Rating |
Min. Install Torque |
Weight |
| 21070 | Single ground clamp bronze alloy |
2.88 O.D. cable or bus | 6 Solid .16 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
275 in. lbs. | 3.25 lbs. |
| 21552 | Single ground clamp bronze alloy |
500 MCM .813 dia. |
8 Solid .128 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
275 in. lbs. | 1.4 lbs. |
| 21307 | Single ground clamp bronze alloy |
1.033 MCM ACSR 1.25 dia. | 6 Solid .16 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
275 in. lbs. | 2.25 lbs. |
| 21575 | Single ground clamp aluminum alloy |
1.033 MCM ACSR 1.25 dia. | 6 Solid .16 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
275 in. lbs. | 1.45 lbs. |
| 10375 | Single ground clamp aluminum alloy |
2" dia. Cable or bus | 4 Solid .18 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
275 in. lbs. | 1.8 lbs. |
| 10375-1 | 10375 ground clamp mounted on a 1-1/4" x 6' fiberglass pole* | 2" dia. Cable or bus | 4 Solid .18 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
275 in. lbs. | 3.8 lbs. |
| 13190-1 | Hanger Stud fits above Cat. No.'s 21070, 21552, 21307 & 21575 | .4 lb. | |||||
| 13210 | Hanger Stud fits 10375 ground clamp | .4 lb. | |||||
| * Note: Ground clamps can be mounted on other lengths of 1-1/4" dia. fiberglass poles. Please specify when ordering | |||||||
![]() |
|||||||
|
|||||||
| Cat. No. | Description | Main Line Range Max. |
Main Line Range Min. |
Max. Jumper Cable |
Max. Fault Current Rating |
Min. Install Torque |
Weight |
| 11190 | Single ground clamp Aluminum alloy |
1.0335 MCM ACSR 1.25 dia. | 8 Solid .12 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 1.3 lbs. |
| 11194 | 11190 ground clamp mounted on 1-1/4" x 6' fiberglass pole* | 1.0335 MCM ACSR 1.25 dia. | 8 Solid .12 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 3.3 lbs. |
| 3172 | Single ground clamp Aluminum alloy |
2" dia. cable or bus | 6 Solid .16 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 2.4 lbs. |
| 3172-1 | 3172 ground clamp mounted on 1-1/4" x 6' fiberglass pole* | 2" dia. cable or bus | 6 Solid .16 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 4.4 lbs. |
| 11195 | 3 wire gound cluster utilizing Cat. No. 11190 ground clamps | 1.0335 MCM ACSR 1.25 dia. | 8 Solid .12 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 5.7 lbs. |
| 11196 | 11195 mounted on 1-1/4" x 6' fiberglass pole* | 1.0335 MCM ACSR 1.25 dia. | 8 Solid .12 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 11.7 lbs. |
| 9678 | 3 wire gound cluster utilizing Cat. No. 3172 ground clamps | 2" dia. cable or bus | 6 Solid .16 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 9 lbs. |
| 9679 | 9678 mounted on 1-1/4" x 6' fiberglass pole* | 2" dia. cable or bus | 6 Solid .16 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 17 lbs. |
| 13210 | Hanger Stud fits above Cat. No.s 11190 and 3172 | .4 lb. | |||||
| * Note: Ground clamps can be mounted on other lengths of 1-1/4" dia. fiberglass poles. Please specify when ordering | |||||||
![]() |
||||||
| Cat. No. | Description | Max. Jaw Opening |
Max. Jumper Cable |
Max. Fault Current Rating |
Min. Install Torque |
Weight |
Tower and Flat Face Ground Clamps with Pressure Type-Bolted Terminals
|
||||||
| 9123 | Single Grd. clamp w/Tee handle alum. alloy | 1-1/2" | 4/0 Str. w/ferrule | 30KA @ 30 cycles | 200 in. lbs. | 1.2 lbs. |
| 9153 | Single Grd. clamp w/Eye screw alum. alloy | 1-1/2" | 4/0 Str. w/ferrule | 30KA @ 30 cycles | 200 in. lbs. | 1.2 lbs. |
| 9123CC | Single Grd. clamp w/Tee handle bronze alloy | 1-1/2" | 4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 3.5 lbs. |
| 9153CC | Single Grd. clamp w/Eye screw bronze alloy | 1-1/2" | 4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 3.5 lbs. |
| Tower and Flat Face Ground Clamps with Threaded Terminals 5/8" - 11 NC Threads | ||||||
| 21571 | Single Grd. clamp w/Eye screw bronze alloy | 1-1/2" | 4/0 Str. | 43KA @ 15 cycles 30KA @ 30 cycles |
276 in. lbs. | 2.2 lbs. |
| 21608 | Single Grd. clamp w/Tee handle bronze alloy | 1-1/2" | 4/0 Str. | 43KA @ 15 cycles 30KA @ 30 cycles |
276 in. lbs. | 2.4 lbs. |
![]() |
|||||||
| Cat. No. | Description | Main Line Range Max. |
Main Line Range Min. |
Max. Jumper Cable |
Max. Fault Current Rating |
Min. Install Torque |
Weight |
| 9071 | Single ground clamp aluminum alloy |
3" dia. bus or cable | 6 Str. .18 dia. |
4/0 Str. w/ferrule | 54KA @ 15 cycles 39KA @ 30 cycles |
200 in. lbs. | 4.2 lbs. |
| 9076 | 9071 mounted on 1-1/4" x 6' fiberglass pole* |
3" dia. bus or cable | 6 Str. .18 dia. |
4/0 Str. w/ferrule | 54KA @ 15 cycles 39KA @ 30 cycles |
200 in. lbs. | 6.2 lbs. |
| 4367-2 | Single ground clamp aluminum alloy |
4" x 1/2" flat bus or 2.875 dia. bus | 6 Solid .16 dia. |
1/0 Str. w/ferrule | 21KA @ 15 cycles 15KA @ 30 cycles |
120 in. lbs. | 2.4 lbs. |
| 4367-4 | 4367-2 mounted on 1-1/4" x 6' fiberglass pole* |
4" x 1/2" flat bus or 2.875 dia. bus | 6 Solid .16 dia. |
1/0 Str. w/ferrule | 21KA @ 15 cycles 15KA @ 30 cycles |
120 in. lbs. | 4.4 lbs. |
| 4367-1 | Single ground clamp aluminum alloy |
3" x 3" square bus | 6 Solid .16 dia. |
1/0 Str. w/ferrule | 21KA @ 15 cycles 15KA @ 30 cycles |
120 in. lbs. | 2.4 lbs. |
| 12282 | Single ground clamp aluminum alloy |
6.625 dia. bus | 1/0 Str. .398 dia. |
4/0 Str. w/ferrule | 54KA @ 15 cycles 39KA @ 30 cycles |
200 in. lbs. | 5.5 lbs. |
| 3172 | Single ground clamp aluminum alloy |
2" dia. cable or bus | 6 Solid .16 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 2.4 lbs. |
| 3172-1 | 3172 mounted on 1-1/4" x 6' fiberglass pole* |
2" dia. cable or bus | 6 Solid .16 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
200 in. lbs. | 4.4 lbs. |
| * Note: Ground clamps can be mounted on other lengths of 1-1/4" dia. fiberglass poles. Please specify when ordering | |||||||
![]() |
| Above, left to right: 21057, 21056, usage example, 21546-1 |
|
Cat. No. 21057 The 21057 clamp body is aluminum. The eye screw is bronze with acme threads for easy installation. Min. range .398 dia. Max range 6.625 dia. Hanger Stud is 5/8" dia. solid copper alloy. Rating is 54,000 amps for 15 cycles and 39,000 amps for 30 cycles. |
Cat. No. 21056 The 21056 clamp body is one piece and is cast from bronze alloy for maximum strength. Eye screw is bronze with acme threads for easy application. Min. range 1-1/4" O.D. Max. range 5" O.D. Clamp rating 54,000 amps for 15 cycles and 39,000 amps for 30 cycles. Stud size is 13/16" O.D. |
Cat. No. 21546-1 The 21546-1 clamp body is one piece and is cast from bronze alloy for maximum strength. Eye screw is bronze with acme threads for easy application. Fits square / rectangular bus. Max size is 3-5/8" x 2-1/4". Clamp rating 43,000 for 15 cycles. Stud dia. 3/4". |
Above |
|
Cat. No. 6767 Compact aluminum alloy cluster bar is 5/8" dia. Bar accepts both "C" type and duckbill type ground clamps, excellent choice for single point grounding practices. Tested for 43,000 amps, 15 cycles |
Cat. No. 6724-1 Aluminum alloy 4-way cable splice
|
Cat. No. 6754 Aluminum base with a 5/8" dia. solid copper alloy bar. Bar accepts both "C" type and duckbill type ground clamps. Excellent choice for single point grounding. Copperbar will hold up to four clamps. Tested for 43,000 amps at 15 cycles |
![]() |
|||||||
• The below listed tools enable operating personnel the capability of grounding de-energized substations safely and easily with use of the Ground Lifting Tool. |
|||||||
| Cat. No. | Description | Main Line Range Max. |
Main Line Range Min. |
Max. Jumper Cable |
Max. Fault Current Rating |
Min. Install Torque |
Weight |
| 13761 | Ground clamp mounted on a 1-1/4" x 8' FG pole with male splice on bottom end* | 3" dia. bus or cable | 6 Str. .18 dia. |
4/0 Str. w ferrule | 54KA @ 15 cycles 39KA @ 30 cycles |
200 in. lb. | 7.2 lbs. |
| 13762 | Ground clamp mounted on a 1-1/4" x 8' FG pole with male splice on bottom end* | 6.625 dia. bus | 1/0 Str. .398 dia. |
4/0 Str. w ferrule | 54KA @ 15 cycles 39KA @ 30 cycles |
200 in. lb. | 8.5 lbs. |
| * Ground clamps have bolted type pressure terminals | |||||||
| 13763 | Ground lifting tool complete with "C" hook, handline block and clamp, 50 ft. 1/2" polypropylene rope installed on a 1-1/4" x 8' fiberglass pole with male splice on bottom end | ||||||
| 546-6 | 1-1/4" x 6' fiberglass extension pole to fit above ground sets and ground lifting tool | 4.1 lbs. | |||||
| 546-8 | 1-1/4" x 8' fiberglass extension pole to fit above ground sets and ground lifting tool | 5.4 lbs. | |||||
| For factory assembled ground set: | |||||||
| 1. Specify Cat. No. of pole mounted ground clamp | |||||||
| 2. Specify Cat. No. of ground clamp to be installed on opposite end of cable for clamps | |||||||
| 3. Specify Ground cable size, color and length for grounding cables | |||||||
Above, top: Capcitor Discharge Tool |
||
| Cat. No. | Description | Weight |
Capacitor Discharge Tool The Capacitor Discharge Tool is designed to safely drain the capacitive charge after the circuit is de-energized. An optional add on resistor to limit discharge current is available and shown below. |
||
| 1004 | Discharge tool with 6 ft. grounding lead | 2.7 lbs. |
| 1005 | Same as above supplied with 8 ft. lead | 3.2 lbs. |
| 1006 | Same as above supplied with 10 ft. lead | 3.8 lbs. |
| 1007 | Same as above supplied with 15 ft. lead | 5.2 lbs. |
| 1008 | Same as above supplied with 20 ft. lead | 6.6 lbs. |
| 6753 | Add on resistor stick. Resistor is rated at 10KV, 10 megohm | .7 lb. |
ELECTRO STATIC PRECIPITATOR GROUNDING TOOL |
||
| 6768 | Factory assembled electro statc precipitator grounding tool | 8 lbs. |
![]() |
| Cat. No. | Description | Main Line Range Max. |
Main Line Range Min. |
Max. Jumper Cable |
Max. Fault Current Rating |
Min. Install Torque |
Weight |
| 21070 | Single ground clamp Bronze alloy |
2.88 O.D. cable or bus | 6 Solid .16 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
275 in. lbs. | 3.25 lbs. |
| 10375 | Single ground clamp Aluminum alloy |
2" dia. cable or bus | 4 Solid .18 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
275 in. lbs. | 1.8 lbs. |
| 10375-1 | 10375 ground clamp mounted on a 1-1/4" x 6' fiberglass pole | 2" dia. cable or bus | 4 Solid .18 dia. |
4/0 Str. w/ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
275 in. lbs. | 3.8 lbs. |
| Note: ground clamps can be mounted on other lengths of 1-1/4" dia. fiberglass poles. Please specify when ordering | |||||||
| Cat. No. | Description | Weight |
| 4730 | Screw ground rod with 5/8" dia. Copperweld rod and 12" bronze handle. 72" overall length | 6.1 lbs. |
| 9738 | Adjustable stringing ground accepts conductors from 6SOL-795 ACSR. Self lubricating rollers. Aluminum alloy with treated steel parts. Tested to 19,000 amps. Accepts 1/0 ground cable | 3.2 lbs. |
| 12423 | Ground cable splice. 4/0 Str. cable max • Used for connecting two ground cables together |
1 lb. |
| 5755-6 | Ground cable splice. 2/0 Str. cable max • Used for connecting ground cables together |
3 lbs. |
Above, bottom row: |
|||||
Copper stranded Grounding Cable
|
|||||
| Cat. No. | Size Plug | Strands | Wire Dia. - Inches | Overall Dia. - Inches | Weight per 1000 ft. |
| Black Jacket Copper Ground Cable | |||||
| 10491 | #2 | 665 | .320 | .435 | 299 lbs. |
| 10492 | 1/0 | 1064 | .410 | .570 | 457 lbs. |
| 10493 | 2/0 | 1323 | .470 | .620 | 555 lbs. |
| 10494 | 4/0 | 2107 | .590 | .740 | 871 lbs. |
| Yellow Jacket Copper Ground Cable | |||||
| 9206 | #2 | 665 | .320 | .435 | 263 lbs. |
| 9201 | 1/0 | 1064 | .410 | .570 | 414 lbs. |
| 13698 | 2/0 | 1323 | .470 | .620 | 504 lbs. |
| 9228 | 4/0 | 2107 | .590 | .740 | 775 lbs. |
| Clear Jacket Copper Ground Cable | |||||
| 13692 | #2 | 665 | .350 | .530 | 300 lbs. |
| 21263 | 1/0 | 1064 | .450 | .640 | 475 lbs. |
| 13701 | 2/0 | 1323 | .490 | .700 | 565 lbs. |
| 21264 | 4/0 | 2107 | .620 | .840 | 856 lbs. |
| Note: Strands shown above are per ASTM 855. All Hastings grounding cable is manufactured to ASTM standards | |||||
| Fault Current Rating Table For Grounding Cable | |||||
| Ground Cable Size AWG | Rating In Amperes Symmetrical RMS 60 HZ | ||||
| 15 Cycles | 30 Cycles | ||||
| #2 | 14,500 amps | 10,000 amps | |||
| 1/0 | 21,000 amps | 15,000 amps | |||
| 2/0 | 27,000 amps | 20,000 amps | |||
| 4/0 | 43,000 amps | 30,000 amps | |||
| Cat. No. | Size AWG | Alcoa Die | Burndy Die | Kearney Die |
| Ferrules for Bolted Type Terminals | ||||
| 11656 | #2 | B71AH | * | * |
| 11657 | 1/0 | B72AH | U241 | 510 |
| 11658 | 2/0 | B73AH | U243 | 9 / 16 |
| 11660 | 4/0 | B74AH | U694 | 11 / 16 |
| * Custom dies can be supplied for Burndy Y-35 and Kearney WH-2 tools | ||||
| Ferrules for 5/8 - 11 NC Threaded Terminals | ||||
| 12998 | #2 | B73AH | U165 | 9 / 16 |
| 12999 | 1/0 | B73AH | U166 | 5 / 8-1 |
| 13000 | 2/0 | B74AH | U166 | 11 / 16 |
| 13001 | 4/0 | U168 | 15 / 16 | |
| Note: Huskie Too Die No. Z-11 may be used on Cat. No. 13001 Ferrule | ||||
![]() |
|||||||
|
|||||||
| Cat. No. | Size AWG | Ferrule Type | Weight | Cat. No. | Size AWG | Ferrule Type | Weight |
| Factory Installed Ferrules | Factory Installed Ferrules | ||||||
| 6756 | #2 | Compression-bolted type | 4 oz. | 6760 | #2 | Comp. 5/8-11 NC Threads | 4 oz. |
| 6757 | 1/0 | Compression-bolted type | 4 oz. | 6761 | 1/0 | Comp. 5/8-11 NC Threads | 4 oz. |
| 6758 | 2/0 | Compression-bolted type | 4 oz. | 6762 | 2/0 | Comp. 5/8-11 NC Threads | 4 oz. |
| 6759 | 4/0 | Compression-bolted type | 4 oz. | 6763 | 4/0 | Comp. 5/8-11 NC Threads | 4 oz. |
| Ordering Info. Specify grounding cable type, size and length from tables above. Order proper ferrule with heat shrink to fit cable and ground clamp termination. * Above units are factory installed. | |||||||
| Ferrules Only — Not Installed | Ferrules Only — Not Installed | ||||||
| P30244 | #2 | Compression-bolted type | 4 oz. | 12998 | #2 | Comp. 5/8-11 NC Threads | 4 oz. |
| P30245 | 1/0 | Compression-bolted type | 4 oz. | 12999 | 1/0 | Comp. 5/8-11 NC Threads | 4 oz. |
| P30246 | 2/0 | Compression-bolted type | 4 oz. | 13000 | 2/0 | Comp. 5/8-11 NC Threads | 4 oz. |
| P30247 | 4/0 | Compression-bolted type | 4 oz. | 13001 | 4/0 | Comp. 5/8-11 NC Threads | 4 oz. |
| P50349 | 5" long heat shrink tube | 1 oz. | P50349 | 5" long heat shrink tube | 1 oz. | ||
| Note: Cat. No. P50349 heat shrink O.D. range is 1.3" max to .375" min. | |||||||
![]() |
|||
DISTRIBUTION/SUB TRANSMISSION GROUNDING SET |
|||
| Grounding Set Components | |||
| Item | Quantity | Description | |
| A | 10 | Cat. No. 21575 ground clamp | |
| B | 10 | Grounding cable ferrule (threaded) | |
| C | 1 | Cat. No. 6767 grounding cluster bar | |
| D | 1 | Cat. No. 4370 screw ground rod | |
| E | 3 cables 6' long | Yellow jacketed grounding cable | |
| 1 cable 12' long | Yellow jacketed grounding cable | ||
| 1 cable 30' long | Yellow jacketed grounding cable | ||
| F | 3 (not shown) | Cat. No. | |
| Cat. No. | Description | Fault Current Rating | Weight |
| 6870 | Grounding set with #2 Str. CU ground cable | 10,000 amps - 30 cycles | 47 lbs. |
| 6871 | Grounding set with 1/0 Str. CU ground cable | 15,000 amps - 30 cycles | 56 lbs. |
| 6872 | Grounding set with 2/0 Str. CU ground cable | 20,000 amps - 30 cycles | 62 lbs. |
| 6873 | Grounding set with 4/0 Str. CU ground cable | 30,000 amps - 30 cycles | 77 lbs. |
| 7254 | Storage bag for grounding set | 2 lbs. | |
![]() |
|||||
| Cat. No. | Description | Weight | Cat. No. | Description | Weight |
| 6715 | Aluminum alloy ground clamp with spike* | 2.1 lbs. | 6716 | Grounding set w/6 ft. 1/0 copper ground cable. Includes flat jaw clamp - Cat. No. 9153 | 6.3 lbs. |
| P30210 | Replaceable spike | 0.1 lb. | 01-4007 | Carrying and storage bag. Will hold up to 3 complete sets | 1.9 lbs. |
| Three phase URD grounding set - 15KV | Three phase live front grounding set | ||||
| 6717 | Grounding set w/6 ft. 1/0 Cu. ground cables, terminal block and flat jaw ground clamp. Rated 10,000 amps for 10 cycles | 18 lbs. | 6718 | Grounding set w/6 ft. 2/0 Cu. ground cables, terminal block and flat jaw ground clamp. Rated 27,000 amps for 15 cycles | 18 lbs. |
| 01-4007 | Carrying and storage bag. | 1.9 lbs. | Carrying and storage bag. | 1.9 lbs. | |
![]() |
|||||
| Cat. No. | Description | Weight | Cat. No. | Description | Weight |
| URD Transformer Grounding Set - 25KV - 1Ø | Three Phase URD Grounding Set - 25KV | ||||
| 6776 | Grounding set w/6 ft. 1/0 Cu. grounding cable. Includes flat jaw clamp Cat. No. 9153 | 7.6 lbs. | 6777 | Grounding set w/6 ft. 1/0 Cu. grounding cables, terminal block and 9153 flat jaw clamp | 32.2 lbs. |
| 01-4007 | Carrying and storage bag. Will hold up to 3 complete sets | 1.9 lbs. | 01-4007 | Carrying and storage bag. Will hold up to 3 complete sets | 1.9 lbs. |
| URD Transformer Grounding Set - 35KV - 1Ø | Three Phase URD Grounding Set - 35KV | ||||
| 6778 | Grounding set w/6 ft. 1/0 Cu. grounding cable. Includes flat jaw clamp Cat. No. 9153 | 7.6 lbs. | 6779 | Grounding set w/6 ft. 1/0 Cu. grounding cables, terminal block and 9153 flat jaw clamp | 32.2 lbs. |
| 01-4007 | Carrying and storage bag. Will hold up to 3 complete sets | 1.9 lbs. | 01-4007 | Carrying and storage bag. Will hold up to 3 complete sets | 1.9 lbs. |
![]() |
|||
|
|||
| Cat. No. | Description | Weight | Carrying/Storage Case |
| 6771 | 15KV grounded parking stand w/threaded ferrule | 5.5 lbs. | 01-4007 or 7254 |
| 6772 | 15KV grounded parking stand w/plug terminal ferrule | 5.5 lbs. | 01-4007 or 7254 |
| 6773 | 25KV grounded parking stand w/threaded ferrule | 6 lbs. | 01-4007 or 7254 |
| 6774 | 25KV grounded parking stand w/plug terminal ferrule | 6 lbs. | 01-4007 or 7254 |
| Note: Either storage case will hold (3) parking stands (dust cap included on all bushings) 01-4007 case has a handle & velcro closure, 7254 is a drawstring bag |
|||
![]() |
||
TRUCK GROUNDING REEL(Spring Retractable) • Reels are designed to be bolted to the vehicle so they can be removed easily for transfer to new trucks. NOTE: Retractable Reel Model 21362 will store and operate with a maximum of 40 feet #2 Str. 1/0 Str. and 2/0 Str. grounding cable only. All ground reels with factory installed cables include a 6 ft. length of 2/0 Cu.Str. ground cable to connect the reel to the truck. A Cat. No. A30205 4-way bronze tee connector is provided to connect one end of the cable to the ground stud on the reel. The other end must be connected to the truck frame by a suitable means. |
||
| Cat. No. | Description | Weight |
| 21362 | Retractable grounding reel only. Tested to 27,000 amps @ 15 cycles | 32 lbs. |
| 21363 | Cat. No. 21362 reel with 40 ft. No. 2 Str. Cu. ground cable (yellow) factory installed and Cat. No. 21307 bronze clamp one end | 47 lbs. |
| 21364 | Cat. No. 21362 reel with 40 ft. 1/0 Str. Cu. ground cable (yellow) factory installed and Cat. No. 21307 bronze clamp one end | 52.5 lbs. |
| 21365 | Cat. No. 21362 reel with 40 ft. 2/0 Str. Cu. ground cable (yellow) factory installed and Cat. No. 21307 bronze clamp one end | 56.45 lbs |
| 21366 | Retractable grounding reel only. Tested to 43,000 amps @ 15 cycles | 83 lbs. |
| 01-029 | Cover, yellow vinyl, for 21362 grounding reel | 2 lbs. |
![]() |
|||||
THe "new" ball socket ground clamp from Hastings is a multi-purpose grounding clamp designed to safely and effectively apply grounds to your electrical system. When used with the ball stud shown above right, the ball socket ground clamp will allow workers to ground equipment such as:
|
|||||
| Cat. No. | Description | Range | Max. Cable | Max. Fault Current | Weight |
| 21720 | Ball socket ground clamp | 1" O.D. ball stud | 4/0 Str. w/Ferrule | 43KA @ 15 cycles 30KA @ 30 cycles |
.75 lb. |
| 21721 | Ball Stud | --- | --- | 43KA @ 15 cycles 30KA @ 30 cycles |
.5 lb. |
![]() |
|||
PORTABLE - PROTECTIVE GROUND MAT The new Portable-Protective "Ground Mat" from HASTINGS provides a method for workers to establish an equal potential zone for multiple grounding applications. The GROUND MAT is manufactured of vinyl-polyester fabric, with high ampacity, tinned-copper braid sewn into a grid pattern. The braided copper on the grid connects to a six inch termination stud on the corner of the mat. The ground mat is then bonded to the equipment being worked on by using a safe and reliable ground cable assembly. WORK APPLICATIONS: FEATURES AND BENEFITS: |
|||
FEATURE |
BENEFIT > The best choice for snow or rain conditions > Select the size for your specific application > Create a larger work area > Standard Yellow & Black Anti-Skid Material > Easy to store > Use your own pre-assembled grounds to create Equal-Potential Zone >Can be used with either side up > Standard hose pressure or a power washer (Allow mat to dry before storing) |
||
| Cat. No. | Description | Color/Material | Weight |
| Standard Mat | |||
| 6610 | 58" x 58" | Yellow vinyl/polyester | 5 lbs. |
| 6615 | 58" x 120" | Yellow vinyl/polyester | 10 lbs. |
| 6620 | 120" x 120" | Yellow vinyl/polyester | 20 lbs. |
| Anti-Skid Mat | |||
| 6610-NS | 58" x 58" | Black hypalon marine fabric | 5 lbs. |
| 6615-NS | 58" x 120" | Black hypalon marine fabric | 10 lbs. |
| 6620-NS | 120" x 120" | Black hypalon marine fabric | 20 lbs. |
| To purchase ground mats with a connecto for bonding multiple mats together, add -C to the catalog number. Example: 6620-C | |||
![]() |
> OSHA: 1910.269(n)(3) states... "Equipontenial Zone." Temporary grounds shall be placed at such locations and arranged in such a manner as to prevent each employee from being exposed to hazardous differences in electrical potential. (The HASTINGS Ground Mat accomplishes this similarly to a grounding cluster bar used on a single point grounding overhead application.) > Methods of Use: When installing or placing the ground mat, the cable grid can be placed facing down or facing up. With the grid face-up it will wear faster than face-down placement. On face-down placement, be sure and guard against, rocks and loose debris that may damage the grounding braid. Inspect your work site and > Applications: The HASTINGS Ground Mat can be applied to most applications using the customers own personal protection ground cable assemblies. The "standard" Ground Mat comes with one 6-inch ferrule, compressed on the copper braid at one corner of the mat. This is the attaching point for installing your ground cables and bonding the mat to the equipment being worked on. As shown below the Ordering Information on the previous page, multiple mats can be bonded together by ordering the mats with a flat one-hole spade compressed on to the braided cable at the opposite corner from the 6-inch ferrule. The one-hole spades can be bolted together to bond the multiple mats. The mats can then be secured to one another with Vn" rope or standard nylon lock-ties. > Care and Maintenance: Cleaning: Normal water hose pressure or a pressure-washer can be used to clean ground mats. (Allow mat to dry before storing.) • Any corrosion, dirt, or sediment must be removed from the grid conductor as soon as possible to avoid damage to the grid. |