Ground / Jumper Assembly Tester
Jumper Assembly Tester

This tester is designed to test in-service grounding and jumpering cable assemblies intact. Regular use of the tester will ensure that the jumper assemblies perform as required for personnel safety. IMPORTANT NOTE: This tester does not test insulative value of jacketed cables

  • Tester is completely self contained, portable and sets up in seconds. Any standard 120 volt grounded outlet will provide power to the tester
  • A reference chart is provided for No., 2 Str. Cu., 1/0 Str. Cu., 2/0 Str. Cu., and 4/0 Str. Cu., cables of specific length to determine the correct test values
  • A built in digital volt meter allows the operator to easily input the correct voltage specified on the reference chart for various sizes and lengths of cable
  • The digital readout ammeter is also built in and tells the operator if the assembly is in good working condition. If not, the jumper must be disassembled for cleaning connections and clamps. Any defects must be corrected before assembly is re-tested and returned to service
  • A 5/8" solid copper bar is provided for attaching clamps. The bar is easily removed for transporting or replacement
  • Maximum voltage output is limited to protect the operator
Cat. No. Description Weight
6714 Ground/Jumper tester complete with copper connection bar. Dimensions with copper bar removed 9" wide x 7-1/2" high x 13" long 30 lbs.
P30605 Replacement copper bar only 21-5/8" long 2.7 lbs.
P15099 Qty. 16 pressure sensitive inspection labels on "peel off" card 0.1 lb.

Ground/Jumper Assembly Tester Accessories
Ground/Jumper Tester Accessories
Cat. No. Description Weight

Grounding Elbow Test Bar

Solid copper bar 5/8" dia. for testing 15, 25 and 35 KV grounding elbow assemblies. Threaded end of test bar is threaded into the terminal after the pin contact and elbow housing is removed.

6714-3 Grounding elbow test bar for use with Cat. No. 6714 tester 3.4 lbs.
Test bar for URD switch terminal Cat. No. A10015 ground assemblies. 5/8" dia. solid copper bar includes a special adapter that the A10015 can be attached to for testing the complete ground jumper assembly
6714-5 Test bar for Cat. No. A10015 switch terminal ground clamp assemblies 2.8 lbs.
Test bar for Ball and socket design ground clamp assemblies - 5/8" dia. solid copper bar is threaded on both ends to accept female ball studs (not supplied) to test ball type ground clamp assemblies intact
6714-4 Test bar for Ball and socket designed ground clamps 2.6 lbs.
Padded carrying case for Cat. No. 6714 ground/jumper tester - made from heavy duty vinyl material. Internal foam padding for protection of tester. Heavy duty nylon handles/straps go around entire case for maximum strength. Loops in front will store up to three test bars.
6714-1 Padded carry case for ground/jumper tester 2 lbs.

Hot Stick Tester
Hot Stick Tester
  • This new and easy to use hot stick tester tests hot sticks wet or dry. The tester meets OSHA 1910.269 for testing "in service" tools (wet test) and new tools (dry test). The tester has a selector switch for wet or dry tests and a dual range scale which gives the operator leakage current values in microamps.
  • Utilizng a 2,500 volt output, the meter is calibrated to indicate the leakage values that would be present if 75 KVAC were applied to a 12" section the fiberglass tool for the wet test and 100 KVAC for the dry test.
  • Portable and lightweight for easy use. Two models available: 120 volt or 220 volt systems. The tester is designed to protect the operator while in use.
  • The tester comes complete with a padded carrying case and directions for proper use. A testing bar is also provided to ensure the tester is working properly.
  • Application and training video included with purcase.
Cat. No. Description Weight
6799 Hot stick tester complete with carrying case and test bar. Operates on 120 volts 5.25 lbs.
6781* Same as above except unit operates on 220 volt systems 8.2 lbs.
* Cat. No. 6781 includes the 6799 meter plus a step-down transformer whih allows the meter to be used on 220 volt systems

Ammeter
Ammeter

Designated as the "Load Spotter", the ammeter is designed for use with Universal Hot Sticks. Designed for use with low and high voltage lines (tested to 345KV). "HOLD"feature captures current readings when applied with telescoping hot sticks from long distances.

  • Patented Slip on Transducfr
  • 0 - 2000 Amp range
  • Large digital display. Numbers are 1" high and 1/2" wide
  • Displays either "Hold" or free run readings
  • Accuracy is ± 1%
  • Wide temperature operation
  • "SNAP" in and out adapter enables the ammeter to be used on conductors up to 2" O.D.
  • Designed for use with telescoping or one piece Universal hot sticks
  • Low battery indicator
  • Weatherproof aluminum housing
Cat. No. Description Weight
6790 Ammeter complete with padded storage / carrying case 2.4 lbs.

 

Hot Line Indicators
Hot Line Indicators
  • Hastings now offers hot line indicators for both distrbution and transmission use
  • Both models verify line conditions/voltage prior to use with an audible signal plus flashing lights
  • The audible signal is 90 decibels, and banks of red lights flash intermttently to warn the operator of voltage potential
  • Both units incorporate a single push button on-switch that is timer operated and will automatically shut the unit off after a period of inactvity
  • Each time the hot line indicator is turned on, each model will run through a pre-programmed test cycle and a green light pilot light will remain on, indicating theunit is operating properly
  • The "distrbution" model 6701 includes a wide range of pre-set voltage levels, (600V, 2000V, 7000V, 11000V) which assist the operator in determining whether full line voltage or a lesser voltage is present
  • The transmission model is for voltage ranges from 69KV to 500KV
  • Both units include 2" diameter hook for contacting conductor and switchgear. Each unit comes with a universal fitting and must be attached to an approved hot stick or hot line tool before use
  • Carrying case included
  • Operates on 9 volt battery (included)
  • Bushing adapters available for 6701 model andURD application
Cat. No. Description Weight
6701 0 - 46KV hot line indicator complete with with carrying case, battery, conductor hook. Unit is provided with operating instructions and safety guide 3.7 lbs
6701-1 Same as above except a larger storage case is provided for storage of bushing adapters 4.2 lbs.
266 Bushing adapter for 15KV and 25KV loadbreak bushing. Also adapts to elastimold 35KV bushings 1.5 lbs.
267 RTE 35KV bushing adapter 1.8 lbs.
6780 69-500KV Transmission hot line indicator 3.7 lbs.

Hot Maximum Meters
Hot Maximum Meters
  • Hot maximum meters are designed to retain the maximum current flow on engergized conductors within ± 10% of full scale reading
  • Maximum meters can be installed with shotgun sticks
  • Ideal for locating faulted sections of overhead and underground circuits
  • Can be used for balancing conductor loads on multiple phase lines
  • Weatherproof - meters are hermetallically sealed
  • Maximum meters can be used on all voltages and are reset with a magnet
  • Can be installed on conductors with a maximum diameter of 1-3/8"
Hot Maximum Meters
Cat. No. Description Scale Amps Weight
11511 Single maximum meter 0 - 200 .5 lb.
11241 Single maximum meter 0 - 500 .5 lb.
11512 Case of three maximum meters with magnet 0 - 200 3.2 lbs.
11240 Case of three maximum meters with magnet 0 - 500 3.2 lbs.
12005 Magnet only --- .3 lb.
Universal installing tool can be used with Tel-O-Poles and maximum meters installed and removed without climbing the structure
10-141 Installing tool shown at bottom right of photos above .05 lb.

Fault Indicators - Manual Reset Type with Red Target Indicator
Fault Indicators
  • Fault indicators are used to detect fault locations on overhead distribution systems
  • Four trip ratings available
  • Bright red indicator for easy visual sighting
  • Installation - indicators can be installed with conventional shotgun sticks or Cat. No. 10-141 installing tool shown above with hot maximum meters can be used
  • Weather proof - fault indicators are hermetallically sealed
  • Indicators can be used on all primary voltages and are reset with a magnet
  • Conductor Range - Indicators can be installed on conductors up to 1-1/2" max. dia.
  • Accuracy - ± 10% of trip rating
Cat. No. Description Trip Rating Weight
21361 Single 100 Amp Fault Indicator 100 Amp .5 lb.
21358 Single 200 Amp Fault Indicator 200 Amp .5 lb.
21359 Single 450 Amp Fault Indicator 450 Amp .5 lb.
21360 Single 800 Amp Fault Indicator 800 Amp .5 lb.
P30306 Carrying case - holds 6 indicators and reset magnet --- 1.7 lb.
12005 Manual reset magnet only --- .3 lb.

Digital High/Low Voltage Phasing Meter
Digital High/Low Voltage Phasing Meter

Phase Tell II

  • Instrument for measuring overhead and underground voltages up to and including 20 KV. Note: the Phase Tell II can be used on voltages up to 80 KV with the use of add on extension resistors listed below
  • Unique circuitry gives phase to phase or phase to ground readings with 3-1/2 digits which are 1/2" high. The meter reads in 10 volt increments for maximum accuracy, example: a 12,470 volt system, phase to phase would read 12.47 on the meter
  • Low voltage resolution capabilities allows the Phase Tell II to be used on secondary voltages, ie; 120/240, 240/480 and other low value potential differences that existing analog meters may not be used on
  • Digital display reads directly in kilovolts with 3-1/2 digits 1/2" high on sharp contrast liquid crystal display. Readout is given to nearest 10 volts.
  • The digital display has a lighted background that can be switched on by the operator, if needed during use in poor light conditions. The meter is solid state design and eliminates problems associated with analog meters
  • The unit is powered by a readily available 9-volt battery and is field replaceable. If a low battery condition exists, it will be indicated on the display. Meter shuts off automatically after 10 minutes without contacting live voltage
  • The coiled, self retracting cable is 16" retracted and 10 ft. when fully extended. This design simplifies use of the instrument
  • Compact storage is provided by a rugged plastic case 19"L x 7"W x 5.5"H. The case will also accomodate a pair of add-on resistor extensions
  • The meter and coiled cable is attached to two 1-1/4" dia. x 12" long fiberglass sticks. Female universal splines are provided on one end to allow attachment on all universal hot sticks. One conductor hook is 2" dia. and one is 2-1/2" dia. Straight probe is provided on other ends.
Cat. No. Description Weight
6706 0 - 20KV digital volt meter with conductor hooks. Unit comes complete with carry case, battery and instructions 5.0 lbs.
6712 Pair of extension resistors to increase operating range 1 lb.
6702-1 Qty. of (1) 15/25KV loadbreak bushing adapter. Also fits elastimold 35KV bushing adapter (2 adapters usually needed) 0.6 lb.
6702-3 Qty. of (1) 35KV loadbreak bushing adapter. Fits RTE 35KV bushing only. (2 adapters usually needed) 0.8 lb.
6702-2 Qty. of (1) D.C. HiPot adapter for use up to 35KV 0.5 lb.
A30119 Storage case only. 21"L x 9.5"W x 7"H 2.1 lbs.
6713 0 - 20KV tester kit. Includes 1 Cat. No. 6706, 2 6' x 1-1/4" universal fiberglass poles with vinyl storage bag 9.2 lbs.

Extended voltage ranges for Phase Tell II. The Phase Tell II may be used on voltages higher than 20 KV phase to phase with additional pairs of extension resistors (Cat. No. 6712)
These extension resistors must be used in pairs to increase the voltage range. The multiplying factors and ranges are listed below

# of pairs Multiplying Factor Range
0 1 20KV
1 2 40KV
2 3 60KV
3 4 80KV

Digital High Voltage Phasing Meter
Digital High Voltage Phasing Meter
  • Circuit Potential Testing - The digital high voltage meter can be used for measuring high voltage on cables. This includes phase to phase and phase to ground 0 - 40KV. Voltages up to 240KV can be obtained in 40KV increments with add on resistors (Cat. No. 6703 listed below)
  • URD Cable Testing - This same meter can be used on underground cables. In addition to phasing and potential testing, the tester can be used to determine the insulation integrity of buried cables with the use of the D.C. HiPot unit.
  • Digital display reads directly in kilovolts with three 1/2" high digits on sharp liquid crystal display. Readout is given to nearest 100 volts.
  • The digital display has a lighted background that can be switched on by the operator, if needed during use in poor light conditions. The meter is solid state design and eliminates problems associated with analog meters
  • The unit is powered by a readily available 9-volt battery and is field replaceable. If a low battery condition exists, it will be indicated on the display. Meter shuts off automatically after 10 minutes without contacting live voltage
  • The coiled, self retracting cable is 16" retracted and 10 ft. when fully extended. This design simplifies use of the instrument
  • Compact storage is provided by a rugged plastic case 19"L x 7"W x 5.5"H. The case will also accomodate a pair of add-on resistor extensions
  • The meter and coiled cable is attached to two 1-1/4" dia. x 16" long fiberglass sticks. Female universal splines are provided on one end to allow attachment on all universal hot sticks. Two conductor hooks with 2" dia. are provided on other end.
Cat. No. Description Weight
6702 0 - 40 KV digital volt meter with conductor hooks. Unit comes complete with carry case, battery, and instructions 5.5 lbs.
6703 Pair of extensions resistors to increase operating voltage 1.3 lbs.
6702-1 Qty. of (1) 15/25KV loadbreak bushing adapter. Also fits elastimold 35KV loadbreak bushing. (2 adapters usually needed) 0.6 lb.
6702-3 Qty. of (1) 35KV loadbreak bushing adapter. Fits RTE 35KV bushing only. (2 adapters usually needed) 0.8 lb.
6702-2 Qty. of (1) D.C. HiPot Adapter for use up to 35KV 0.5 lb.
A30119 Storage case only. 21"L x 9.5"W x 7"H 2.1 lbs.
6711 0 - 40KV Tester kit includes 1 Cat. No. 6702, 2 6' x 1-1/4" dia. fiberglass poles with vinyl storage bag 10.0 lbs.
Extended voltage ranges for Phase Tel (Cat. No. 6702). The Phase Tell may be used on voltages higher than 40KV phase to phase with additional pairs of extension resistors (Cat. No. 6703).
These extension resistors must be used in pairs to increase the voltage ranges. The multiplying factors and ranges are as follows:
# of pairs Multiplying Factor Range
0 1 40KV
1 2 80KV
2 3 120KV
3 4 160KV
4 5 200KV
5 6 240KV

D.C. HiPot Adapter and Phase Tell Tester
DC HiPot Adapter and Phase Tell Tester
Above: top two images - HiPot Adapter and illustration showing correct usage
bottom row: Phase Tell Tester (left) and Phase Tell Tester in use (right)

The DC HiPot adapter is an encapsulated high voltage rectifier for use on the Hastings Cat. No. 6702 Phase Tell Meter. When used in conjunction with the Phase Tell, it will enable the operator to perform the following tests on systems up to and including 35KV phase to phase:

  1. Test section of underground cables to determine the integrity of insulation, ie., failed cables
  2. Determine if all grounds have been removed after completion of working on a de-energized underground system
  • The HiPot adapter housing is fiberglass, 13" in length. A bell shaped female end allows it to be coupled to the end of the Phase Tell after the conductor hook is removed. The appropriate URD bushing adapter can then be installed on the other end of the HiPot adapter
  • Convenient - more portable and easier to operate than conventional cable testing equipment
  • Safety - use of the DC HiPot adapter to test cables for faults eliminates undue stress on the cable insulation when used in conjunction with the Phase Tell
Cat. No. Description Weight
6702-2 DC HiPot adapter for use with the Hastings 6702 Phase Tell unit. Operating instructions are included 0.5 lbs.

Phase Tell Tester

  • The Phase Tell Tester is designed to test the following meters: Cat. No.'s 6702, 6706 and 6704
  • The tester verifies that all internal components of the listed meters are functioning properly
  • The tester is powered by a readily available 9 volt battery which is easily replaced
  • An instruction label is attache to the tester for easy reference. Tester is compact and will store in the Phase Tell carrying case

Regulator Neutral Detector
Regulator Neutral Detector
  • The RND (Regulator Neutral Detector) insures that the operator has the regulator in its neutral position prior to disconnecting the regulator from the circuit (bypassing)
  • Use of the RND eliminates high or low voltages caused by cycling the regulator to the upper or lower limits and then counting steps back to neutral
  • The RND provides benefits not found in existing testers presently being used for detecting the regulator neutral
  • Use of the RND may eliminate outages taken because of uncertainties of the regulator neutral position
  • The RND verifies the neutral position on regulators
  • The RND works with step type and induction type regulators
  • 0 to 2000 volt range is shown in one volt increments
  • The RND works with all regulators up to and including 34.5KV systems
  • No range selector is required
  • The RND has a digital display with 1/2" high LCD digits for easy viewing
  • Lighted meter for use at night, or in poor lighting conditions can be switched on by the operator
  • The RND is powered by a readily available 9 volt battery and is field replaceable. If a low battery condition exists, it will be indicated on the display
  • The RND verifies the step indicator has not slipped one step
  • A female universal spline allows unit to be attached to all universal hot sticks
  • Contact electrodes are knurled to aid contact with conductors. Electrodes are removable for compact storage
Cat. No. Description Weight
6709-1 Regulator Neutral Detector complete with carrying case, battery and instructions 4.6 lbs.
A30113 Replacement carrying case 2.4 lbs.

Underground High Voltage Meter
Underground High Voltage Meter
  • Circuit potential testing - the digital high voltage meter can be used for measuring voltage potential up to and including 20KV line to ground
  • Accessories - Loadbreak bushing adapters for 15, 25 and 35 KV underground and primary systems
  • Digital display reads directly in kilovolts with three 1/2" high digits on sharp contrast liquid crystal display. Readout is given to the nearest 100 volts. Example: a 7,200 volt line phase to ground will read 7.2 on the display
  • The digital display has a lighted background that can be switched on by the operator if needed during use in poor light conditions. The meter is solid state and eliminates problems associated with analog meters
  • The unit is powered by a nine volt battery and is field replaceable. If a low battery condition exists, it will be indicated on the display
  • The coiled, self retracting cable is 16" retracted and 10 ft. when fully extended
  • Compact storage is provided by a rugged plastic case 19"L x 7"W x 5.5"H. The case will also accommodate a pair of bushing adapters
  • A heavy duty alligator clip is installed on the end of the coiled cord for attachment to system ground
  • A female spline is provided on one end to allow instrument to all universal hot sticks
Cat. No. Description Weight
6704 Underground high voltage meter. Unit comes complete with carrying case, battery and instructions 4.8 lbs.
Accessories
Note: A choice of below listed loadbreak bushing adapters will be required for deadfront construction
6702-1 Qty. of (1) 15/25KV loadbreak bushing adapter (also fits Elastimold 35KV loadbreak bushing) 0.6 lb.
6702-3 Qty. of (1) 35KV loadbreak bushing adapter (also fits RTE 35KV bushing only) 0.8 lb.
A30119 Replacement storage case only 2.1 lbs.

Hastings TLC Meter
TLC Meter
  • The instrument for determining the condition of your transformers before placing them into service or back into service after being de-energized
  • Tests new transformers and troubleshoots in-service transformers
  • Provides operating personnel a safe and reliable method to verify distribution transformers do not have shorted or open windings prior to energizing
  • Detects failures in transformers before loading and transporting to the job site. Eliminates blowing cutout fuses to determine condition of transformer. Reduces potential hazards of oil spills and costly cleanup caused by energizing shorted transformers
  • Easy to use - hand held lightweight tester has built in "push button" test feature prior to applying it on a transformer. 3 bright LED light signal condition of transformer. Green - Pass, Yellow - Open, Red - Shorted
  • Wide range - can be used on transformers up to and including 3300 KVA
  • Other uses - tester can be used to verify secondary services are not shorted prior to energizing the transformer
  • Specifications - tester is powered by a 9 volt, easy to replace alkaline battery, which can be used to -40șC. Tester is supplied with a weatherproof, high impact resistant plastic storage and carrying case with instructions
  • Overhead or URD application